=PAGE=
6.1  NASTRAN MESSAGES

   There are three categories of diagnostic messages in NASTRAN. They are:

   1. Rigid format error messages

   2. Structure plotter error messages

   3. NASTRAN system and user diagnostic messages

   The rigid format error messages are fully described in Volume II under the
description of the individual rigid formats. The structure plotter error
messages are described in Section 4.2.3. The NASTRAN system and user
diagnostic messages are detailed in this section.

   The system and user diagnostic messages issued by NASTRAN are identified by
numbers. Message numbers have been assigned in groups as follows:

      1  - 1000   Preface Messages

   1001  - 2000   Executive Module Messages

   2001  -        Functional Module Messages

These messages have the following format:

                               
         SYSTEM    FATAL       
   ***             WARNING      MESSAGE id, text
         USER      INFORMATION 
                               

where "id" is a unique message identification number and "text" is the message
as indicated in capital letters for each of the diagnostic messages. A series
of asterisks in the text indicates information that will be filled in for a
specific use of the message, such as the number of a grid point or the name of
a bulk data card. Many of the messages are followed by additional explanatory
material, including suggestions for remedial action.

   The system and user messages described in this section pertain only to
those messages generated by NASTRAN. Although these messages can appear at
various places in the output stream, they should be easily identified by their
format. The various computer operating systems also produce diagnostic
messages that can appear at various places in the output stream. The format of
these messages will vary with the operating system. Reference should be made
to the operating system manuals for interpretation of the messages that are
not generated by NASTRAN.

   System messages refer to diagnostics that are associated with program
errors. In general, you cannot correct such. Refer to the Programmer's Manual
and assistance secured from the programming staff. User messages refer to
errors that are usually associated with the preparation of the NASTRAN Data
Deck. Corrective action is indicated in the message text or the explanatory
information following the text. In some cases reference may have to be made to
other sections of the User's Manual for proper card formats or for
clarification of procedures.

   Fatal messages cause the termination of the execution following the
printing of the message text. These messages will always appear at the end of
the NASTRAN output. Warning and information messages will appear at various
places in the output stream. Such messages only convey warnings or
information. Consequently, the execution continues in a normal manner
following the printing of the message text.

   As an example, consider message number 2025, which will appear in the
printed output as follows:

   *** USER FATAL MESSAGE 2025, UNDEFINED COORDINATE SYSTEM 102.

The three leading asterisks (***) are always present in the system and user
diagnostic messages. The word USER indicates that this is a user message
rather than a system message. The word FATAL indicates that this is a fatal
message rather than a warning or an information message. The number 2025 is
the identification number for this message. The text of the message follows
the comma (,). The number 102 replaces the asterisks (****) in the general
message text, and indicates that 102 is the identification number of the
undefined coordinate system.

=PAGE=
6.2  PREFACE MESSAGES

  1 ***  USER WARNING MESSAGE 1, POSSIBLE ERROR IN DMAP INSTRUCTION ****,
         INSTRUCTION NO. ****, ASSUMED FIRST INPUT FILE IS NULL.

        You have specified N input data blocks when there should be N+1.

  2 ***  USER WARNING MESSAGE 2, POSSIBLE ERROR IN DMAP INSTRUCTION ****,
         INSTRUCTION NO. ****, PARAMETER NAMED ******** IS DUPLICATED.

        No harm done. Parameter is saved just once.

  3 ***  USER FATAL MESSAGE 3, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, FORMAT ERROR IN PARAMETER NO. ***

        Double delimiter appears in parameter section of previous DMAP
        instruction.

  4 ***  SYSTEM FATAL MESSAGE 4, MPL PARAMETER ERROR, MODULE NAME = ********
         PARAMETER NO. ***

        MPL entry for module is incorrect. See subroutine XMPLDD.

  5 ***  USER FATAL MESSAGE 5, PARAMETER INPUT DATA ERROR, ILLEGAL VALUE FOR
         PARAMETER NAMED ********

        The type of the parameter on a PARAM card is inconsistent with the
        type of the parameter by the same name in the above DMAP instruction.

  6 ***  USER FATAL MESSAGE 6, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, ILLEGAL TYPE FOR PARAMETER NO. ***

        The type of the parameter in the DMAP instruction does not correspond
        to type requested in DMD or MFD section of the Programmer's Manual.

  7 ***  USER FATAL MESSAGE 7, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, PARAMETER NO. *** NEEDS PARAMETER NAME.

        Parameter is not in correct format.

  8 ***  USER FATAL MESSAGE 8, BULK DATA PARAM CARD ERROR. MUST NOT DEFINE
         PARAMETER NAMED ********

        The "N" in V,N,******** means that you cannot set the value of the
        parameter with the name ******** on a PARAM card.

  9 ***  USER FATAL MESSAGE 9, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, VALUE NEEDED FOR PARAMETER NO. ***

        Constant needs value in DMAP instruction or on a PARAM card.

 10 ***  USER POTENTIALLY FATAL MESSAGE 10, POSSIBLE ERROR IN DMAP INSTRUCTION
         ****, INSTRUCTION NO. ****, DEFAULT OPTION FOR INPUT DATA BLOCKS. MAKE
         SURE MISSING BLOCKS ARE NOT REQUIRED.

 11 ***  USER POTENTIALLY FATAL MESSAGE 11, POSSIBLE ERROR IN DMAP INSTRUCTION
         ****, INSTRUCTION NO. ****, DEFAULT OPTION FOR OUTPUT DATA BLOCKS. MAKE
         SURE MISSING BLOCKS ARE NOT REQUIRED.

 12 ***  USER FATAL MESSAGE 12, ERROR IN DMAP INSTRUCTION NO. ****, ILLEGAL
         CHARACTER IN DMAP INSTRUCTION NAME.

        Name must be 8 or fewer alpha-numeric characters, the first character
        being alpha.

 13 ***  USER FATAL MESSAGE 13, DMAP INSTRUCTION NOT IN MODULE LIBRARY.

 14 ***  SYSTEM FATAL MESSAGE 14, ARRAY NAMED ******** OVERFLOWED [AT DMAP
         INSTRUCTION NO. ****]

        See XGPI module description in the MFD section of the Programmer's
        Manual.

 15 ***  USER FATAL MESSAGE 15, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, INCONSISTENT TYPE USED FOR PARAMETER NAMED ********

        This parameter was used in a previous DMAP instruction which gave it
        a different type. See Section 5.2.1.

 16 ***  USER FATAL MESSAGE 16, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, ILLEGAL FORMAT.

 17 ***  USER FATAL MESSAGE 17, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, UNIDENTIFIED NASTRAN CARD KEYWORD ********. ACCEPTABLE KEYWORDS
         FOLLOW ---

 18 ***  USER FATAL MESSAGE 18, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, TOO MANY PARAMETERS IN DMAP PARAMETER LIST.

        Incorrect calling sequence for DMAP instruction.

 19 ***  USER FATAL MESSAGE 19, LABEL NAMED ******** IS MULTIPLY DEFINED.

        LABEL named appears in more than one place in the DMAP program.

 20 ***  USER FATAL MESSAGE 20, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, ILLEGAL CHARACTERS IN PARAMETER NO. ***

        Name must be 8 or fewer alpha-numeric characters, the first character
        being alpha.

 21 ***  USER FATAL MESSAGE 21, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, PARAMETER NAMED ******** IS NOT IN PRECEDING DMAP INSTRUCTION
         PARAMETER LIST.

        Parameters in a SAVE instruction must appear in the immediately
        preceding DMAP instruction.

 22 ***  USER POTENTIALLY FATAL MESSAGE 22, POSSIBLE ERROR IN DMAP INSTRUCTION
         ****, INSTRUCTION NO. ****, DATA BLOCK NAMED ******** APPEARS AS INPUT
         BEFORE BEING DEFINED

        See Section 5.2.

 23 ***  USER FATAL MESSAGE 23, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, DATA BLOCK NAMED ******** IS NOT REFERENCED IN SUBSEQUENT
         FUNCTIONAL MODULE.

        See Section 5.2. Error can be suppressed by adding the following:

         PARAM   //*NOP*/TRUE=-1 $
         COND    LABELXXX,TRUE $
         TABPT   ********,,,,// $
         LABEL   LABELXXX $

 24 ***  SYSTEM FATAL MESSAGE 24, CANNOT FIND FILE NAMED ******** ON DATA POOL
         TAPE.

        The contents of /XDPL/ do not match the contents of the Pool Tape.

 25 ***  USER FATAL MESSAGE 25, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, PARAMETER NAMED ******** NOT DEFINED.

        Parameter is referenced in a functional module, but is nowhere
        defined.

 26 ***  USER FATAL MESSAGE 26, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, LABEL NAMED NOT DEFINED.

        LABEL name does not appear in LABEL instruction.

 27 ***  USER WARNING MESSAGE 27, LABEL NAMED ******** NOT REFERENCED.

        LABEL name appears only in a LABEL instruction.

 28 ***  SYSTEM FATAL MESSAGE 28, UNEXPECTED END OF TAPE ON NEW PROBLEM TAPE.

        Either an EOT was truly encountered or file linkage has been
        destroyed in /XFIST/, /XPFIST/, and/or /XXFIAT/. This message will
        also appear when tape files on the NASTRAN Card have been declared
        disk files but insufficient space has been allocated for this
        purpose.

 29 ***  SYSTEM FATAL MESSAGE 29, UNEXPECTED END OF TAPE ON OLD PROBLEM TAPE.

        See Message 28.

 30 ***  SYSTEM FATAL MESSAGE 30, UNEXPECTED END OF TAPE ON DATA POOL TAPE.

        See Message 28.

 31 ***  SYSTEM FATAL MESSAGE 31, CONTROL FILE ******** INCOMPLETE OR MISSING
         ON NEW PROBLEM TAPE.

        Data block XCSA is not in correct format or it is missing.

 32 ***  USER FATAL MESSAGE 32, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, FILE NAMED ******** MUST BE DEFINED PRIOR TO THIS INSTRUCTION.

        See Section 5.2.

 33 ***  SYSTEM FATAL MESSAGE 33, NAME (********) IN NEW CONTROL FILE DICTIONARY
         NOT VALID.

        The first record of data block XCSA on Problem Tape contains a name
        which is not recognized by XGPI module.

 34 ***  SYSTEM FATAL MESSAGE 34, CANNOT TRANSLATE DMAP INSTRUCTION NO. ****

        Refer to Section 5 of the User's Manual or Section 4 of the
        Programmer's Manual for the correct format of the instruction.

 35 ***  USER FATAL MESSAGE 35, INCORRECT OLD PROBLEM TAPE MOUNTED. ID OF TAPE
         MOUNTED = ********,********,**/**/** REEL =***. ID OF TAPE DESIRED =
         ********,********,**/**/** REEL =***.

        Wrong reel mounted for multi-reel Problem Tape.

 36 ***  SYSTEM FATAL MESSAGE 36, CANNOT FIND FILE NAMED ******** ON OLD PROBLEM
         TAPE.

        The header record of the file on Problem Tape does not match the file
        name in restart dictionary.

 37 ***  USER WARNING MESSAGE 37, POSSIBLE ERROR IN DMAP INSTRUCTION ****,
         INSTRUCTION NO. ****, WARNING ONLY - MAY NOT BE ENOUGH FILES AVAILABLE
         FOR MODULE REQUIREMENTS. FILES NEEDED = *** FILES AVAILABLE = ***.

        Program will execute if enough data blocks referenced by the module
        are purged. Purged data blocks are not assigned files.

 38 ***  SYSTEM FATAL MESSAGE 38, NOT ENOUGH CORE FOR GPI TABLES.

        Increase Region Size, Field Length, HICORE allocation, or the length
        of the open core COMMON block, depending on the machine being used.

 39 ***  SYSTEM FATAL MESSAGE 39, RIGID FORMAT DMAP SEQUENCE DOES NOT CORRESPOND
         TO MED TABLE.

        The MED Table must have the same number of entries as there are DMAP
        instructions in the DMAP sequence.

 40 ***  USER FATAL MESSAGE 40, ERROR IN ALTER DECK - CANNOT FIND END OF DMAP
         INSTRUCTION.

        Check the ALTER part of the Executive Control Deck.

 41 ***  SYSTEM FATAL MESSAGE 41, TABLES INCORRECT FOR REGENERATING DATA BLOCK

        File Name Table and MED Table used by routine XFLDEF are wrong.

 42 ***  USER WARNING MESSAGE 42, POSSIBLE ERROR IN DMAP INSTRUCTION ****,
         INSTRUCTION NO. ****, PARAMETER NAMED ******** ALREADY HAD VALUE
         ASSIGNED PREVIOUSLY.

        Parameter appears in a previous instruction which assigned it a
        value. The previous value will be used.

 43 ***  USER FATAL MESSAGE 43, INCORRECT FORMAT FOR NASTRAN CARD.

 44 ***  USER FATAL MESSAGE 44, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, UNABLE TO FIND END DMAP INSTRUCTION.

        You have ALTERed out the END instruction.

 45 ***  USER POTENTIALLY FATAL MESSAGE 45, POSSIBLE ERROR IN DMAP INSTRUCTION
         ****, INSTRUCTION NO. ****, DATA BLOCK NAMED ******** ALREADY APPEARED
         AS OUTPUT.

        See Section 5.2.

 46 ***  USER FATAL MESSAGE 46, INCORRECT REENTRY POINT.

        The last reentry card in the restart dictionary has a DMAP
        instruction number greater than the instruction number on the END
        card of the DMAP program.

 47 ***  USER FATAL MESSAGE 47, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, THIS INSTRUCTION CANNOT BE FIRST INSTRUCTION OF LOOP.

        CHKPNT DMAP instruction must not follow a LABEL instruction which is
        located at the top of a loop.

 48 ***  USER WARNING MESSAGE 48, POSSIBLE ERROR IN DMAP INSTRUCTION ****,
         INSTRUCTION NO. ****, DATA BLOCK ******** IS ALWAYS REGENERATED,
         THEREFORE IT WILL NOT BE CHECKPOINTED.

        This data block is generated by the Input File Processor (IFP) and
        must not be checkpointed to insure proper restart.

 49 ***  SYSTEM FATAL MESSAGE 49, MPL TABLE (MODULE PROPERTIES LIST) IS
         INCORRECT.

        Error is in COMMON block /XGP12/.

 51 ***  SYSTEM FATAL MESSAGE 51, NOT ENOUGH OPEN CORE FOR XGPIBS ROUTINE.

        Additional core memory is required.

 52 ***  SYSTEM FATAL MESSAGE 52, NAMED COMMON /XLINK/ IS TOO SMALL.

        There must be one word in LINK table for every entry in MPL.

 53 ***  USER FATAL MESSAGE 53, INCORRECT FORMAT IN ABOVE CARD.

 54 ***  USER WARNING MESSAGE 54, PARAMETER NAMED **** NOT REFERENCED.
 (1)

 54 ***  SYSTEM WARNING MESSAGE 54, THE NUMBER OF MODULES SPECIFIED IN THE LINK
 (2)     SPECIFICATION TABLE, **** EXCEEDS THE ALLOWABLE NUMBER SPECIFIED BY
         SEMDBD, ****

        The parameter LXLINK in COMMON /XLINK/ was exceeded when a new module
        was added to the program.

 55 ***  USER FATAL MESSAGE 55, PRECHK NAME LIST EXCEEDS MAXIMUM LIMIT (50).

 56 ***  USER WARNING MESSAGE 56, ILLEGAL OPTION ON XDMAP CARD - IGNORED.

 57 ***  USER FATAL MESSAGE 57, VARIABLE REPT PARAMETER MUST BE AN INTEGER.

 58 ***  USER FATAL MESSAGE 58, VARIABLE REPT PARAMETER MUST BE DEFINED PRIOR TO
         INSTRUCTION.

 59 ***  USER WARNING MESSAGE 59, POOL FILE ERROR - DMAP CROSS-REF TERMINATED.

 60 ***  USER POTENTIALLY FATAL MESSAGE 60, INSUFFICIENT OPEN CORE FOR DMAP
         CROSS-REF - TERMINATED.

 61 ***  USER FATAL MESSAGE 61, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, SAVE INSTRUCTION OUT OF SEQUENCE.

 62 ***  USER FATAL MESSAGE 62, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, INCORRECT NUMBER OF INPUT DATA BLOCKS ENCOUNTERED.

 63 ***  USER FATAL MESSAGE 63, ERROR IN DMAP INSTRUCTION ****, INSTRUCTION NO.
         ****, INCORRECT NUMBER OF OUTPUT DATA BLOCKS ENCOUNTERED.

 64 ***  USER WARNING MESSAGE 64, **** IS NOT DEFINED AS A NASTRAN FILE AND WILL
         BE IGNORED.

 65 ***  SYSTEM FATAL MESSAGE 65, POINTER ** = **** DOES NOT AGREE WITH LMPL =
         ****

        An error has been made in counting the number of MPL array entries
        for a particular module or the LMPL value has not been updated.
        Recheck any recent changes to the XMPLDD subroutine.

 66 ***  SYSTEM FATAL MESSAGE 66, ILLEGAL PARAMETER TYPE CODE.

        The parameter type code in an MPL table entry must be an integer
        between 1 and 6. See Section 2.4.2.2 of the Programmer's Manual.

 67 ***  SYSTEM FATAL MESSAGE 67, ERROR IN PARAMETER SEQUENCE.

        A format error exists in an MPL table entry for a particular module.
        See Section 2.4.2.2 of the Programmer's Manual.

 68 ***  SYSTEM FATAL MESSAGE 68, ILLEGAL WORD COUNT.

        The number of words in an MPL table entry for a particular module
        must be a positive integer.

201 ***  USER FATAL MESSAGE 201, REQUESTED BULK DATA DECK ********, NOT ON USER
         MASTER FILE.

        Requested UMF problem identification number not found on currently
        mounted UMF tape.

202 ***  SYSTEM FATAL MESSAGE 202, UMF COULD NOT BE OPENED.

        User's Master File (UMF) not present (destroyed) in FIST.

203 ***  SYSTEM FATAL MESSAGE 203, ILLEGAL EOR ON UMF.

        User's Master File (UMF) contains no records in requested file.

204 ***  USER FATAL MESSAGE 204, COLD START, NO BULK DATA.

        No data cards were found after the BEGIN BULK card. A blank card will
        satisfy this rule.

205 ***  USER WARNING MESSAGE 205, COLD START, DELETE CARDS IGNORED.

        Delete (/) cards were present within the Bulk Data Deck and were
        ignored.

206 ***  USER FATAL MESSAGE 206, PREVIOUS ******** CONTINUATION CARDS, THOUGH
         VALID, CANNOT BE PROCESSED BECAUSE OF ERRORS ON OTHER RELATED
         CONTINUATION CARDS.

207 ***  USER INFORMATION MESSAGE 207, BULK DATA NOT SORTED, XSORT WILL REORDER
         DECK.

        The Bulk Data Deck was not in alpha-numeric sort. Sorting will be
        performed. Sorting of a large deck can be time consuming.

208 ***  USER FATAL MESSAGE 208, PREVIOUS CARD IS A DUPLICATE PARENT.

        Two or more cards were found with columns 74-80 identical and a
        continuation card is present with that mnemonic (columns 2-8).

209 ***  USER FATAL MESSAGE 209, PREVIOUS ******** CONTINUATION MNEMONICS HAVE
         NO PARENTS AND/OR ARE DUPLICATES.

        This message results due to either or both of the following reasons:
        (a) one or more cards with continuation mnemonics in columns 2
        through 8 could not be matched with any other card continuation
        mnemonic in columns 73 through 80 or (b) two or more cards with
        continuation mnemonics in columns 2 through 8 were identical.

210 ***  SYSTEM FATAL MESSAGE 210, SCRATCH COULD NOT BE OPENED.

        One of the required scratch files was not present (destroyed) in
        FIST.

211 ***  SYSTEM FATAL MESSAGE 211, ILLEGAL EOR ON SCRATCH.

        A required scratch file was formatted improperly.

212 ***  SYSTEM FATAL MESSAGE 212, ILLEGAL EOF ON ITAPE4.

        Scratch file containing continuations was mis-positioned.

213 ***  SYSTEM FATAL MESSAGE 213, ILLEGAL EOF ON OPTP.

        Old Problem Tape contained no bulk data (illegal format).

214 ***  SYSTEM FATAL MESSAGE 214, OPTP COULD NOT BE OPENED.

        Old Problem Tape (OPTP) not present (destroyed) in FIST.

215 ***  SYSTEM FATAL MESSAGE 215, NPTP COULD NOT BE OPENED.

        New Problem Tape (NPTP) not present (destroyed) in FIST.

216 ***  SYSTEM FATAL MESSAGE 216, ILLEGAL INDEX.

        FORTRAN computed GO TO has received an illogical value.

217 ***  SYSTEM FATAL MESSAGE 217, ILLEGAL EOF ON ITAPE4.

218 ***  USER FATAL MESSAGE 218, ILLEGAL VALUE OR FORMAT SPECIFIED IN PARM
         FIELD.

        The core statistics request or the number of bytes to free back to
        the operating system has not been defined properly on the EXEC
        statement card. (IBM only.)

219 ***  USER FATAL MESSAGE 219, MISSING ENDDATA CARD.

220 ***  USER FATAL MESSAGE 220, MISSING ENDDATA CARD.

221 ***  USER FATAL MESSAGE 221, EXTRANEOUS DATA IN FIELD 1 OF BULK DATA DELETE
         CARD.

238 ***  USER INFORMATION MESSAGE 238, TURN DIAG 38 ON FOR ADDITIONAL ELEMENT
         PROCESSING INFORMATION.

        DIAG 38 gives a list of elements being processed. If the EMG module
        stops due to element error, and DIAG 38 is on, the last element on
        the list is the one that erred.

248 ***  USER INFORMATION MESSAGE 248, TURN DIAG 48 ON FOR NASTRAN RELEASE NEWS,
         DIAG DEFINITION, NEW DMAP MODULES, AND NEW BULKDATA CARDS INFORMATION.

        If DIAG 48 is on, the diagnostic definition, the new DMAP modules and
        new bulkdata cards that were not printed in the 1986 User's Manual,
        and the NASTRAN release news for the last two years are printed on
        your NASTRAN output listing, and NASTRAN computation continues.

        If DIAGs 48 and 20 are both turned on, the same information as above,
        plus an expanded NASTRAN release news since 1983 are printed. The
        NASTRAN job then stops.

300 ***  USER FATAL MESSAGE 300, DATA ERROR IN FIELD UNDERLINED.
(1)

        A data error as described in the text has been detected by utility
        routine XRCARD or RCARD.

300 ***  USER FATAL MESSAGE 300, INVALID DATA COLUMN 72.
(2)

        Error in format of exponent.

300 ***  USER FATAL MESSAGE 300, INTEGER DATA OUT OF MACHINE RANGE.
(3)

        The limits are (2^31)-1 for IBM, (2^59)-1 for CDC, (2^35)-1 for
        UNIVAC, and (2^31)-1 for VAX.

300 ***  USER FATAL MESSAGE 300, INVALID CHARACTER FOLLOWING INTEGER IN COLUMN
(4)      ***

        Either an illegal delimiter was detected or a real number is missing
        the decimal.

300 ***  USER FATAL MESSAGE 300, DATA ERROR - UNANTICIPATED ChARACTER IN COLUMN
(5)      ***

        A +/- E or +/- D was expected based on other input data.

300 ***  USER FATAL MESSAGE 300, DATA ERROR MISSING DELIMITER OR REAL POWER OUT
(6)      OF MACHINE RANGE.

        Either no delimiter was found or the power was exceeded. The limits
        are E-78 to E+75 for IBM, E-38 to E+38 for UNIVAC, E-294 to E+322 for
        CDC, and E-38 to E+38 for VAX.

300 ***  USER FATAL MESSAGE 300, ROUTINE XRCARD FINDS OUTPUT BUFFER TOO SMALL TO
(7)      PROCESS CARD COMPLETELY.

301 ***  USER WARNING MESSAGE 301, BULK DATA CARD ******** CONTAINS INCONSISTENT
         DATA. SORTED CARD COUNT = ******

302 ***  USER WARNING MESSAGE 302, ONE OR MORE GRID CARDS HAVE DISPLACEMENT
         COORDINATE SYSTEM ID OF -1.

303 ***  SYSTEM FATAL MESSAGE 303, NO OPEN CORE FOR IFP.

        Overlay structure must be redefined.

304 ***  SYSTEM FATAL MESSAGE 304, IFP NOT READING NPTP. FILE BEING READ = ****

        The Input File Processor subroutine IFP attempts to locate the bulk
        data file on the NPTP by searching it forward. The first two words of
        the file header records are examined for a match with the Hollerith
        string BULKDATA. If the bulk data is not found by the fifth file, the
        assumption is made that IFP is either not reading NPTP or that it has
        been badly written. The header record of the fifth file is printed as
        part of the message.

305 ***  SYSTEM FATAL MESSAGE 305, GINO CANNOT OPEN FILE ******

        Unexpected nonstandard return from OPEN.

306 ***  SYSTEM FATAL MESSAGE 306, READ LOGIC RECORD ERROR.

        Short record encountered. Bulk data card images occupy 20 words.

307 ***  USER FATAL MESSAGE 307, ILLEGAL NAME FOR BULK DATA CARD ******.

        See Section 2.4.

308 ***  USER FATAL MESSAGE 308, CARD ******** NOT ALLOWED IN ******** APPROACH.

        See Section 2.4.

309 ***  USER WARNING MESSAGE 309, CARD ******** IMPROPER IN ******** APPROACH.

        See Section 2.4.

310 ***  USER FATAL MESSAGE 310, CARD ******** NOT ALLOWED IN SAME DECK AS AXIC
         CARD.

        See Section 2.4.

311 ***  USER FATAL MESSAGE 311, NONUNIQUE FIELD 2 ON BULK DATA CARD ********.
         SORTED CARD COUNT = ****.

        The sorted bulk data card indicated must have a unique integer in
        field 2.

312 ***  USER FATAL MESSAGE 312, TOO MANY CONTINUATIONS FOR BULK DATA CARD
         ********. SORTED CARD COUNT = ****.

        See bulk data card description in Section 2.4.

313 ***  USER FATAL MESSAGE 313, ILLEGAL NUMBER OF WORDS ON BULK DATA CARD
         ********. SORTED CARD COUNT = ****.

        See bulk data card description in Section 2.4.

314 ***  SYSTEM FATAL MESSAGE 314, INVALID CALL FROM IFP. K = ****.

        Code error, machine failure, or cell is being destroyed.

315 ***  USER FATAL MESSAGE 315, FORMAT ERROR ON BULK DATA CARD ********. SORTED
         CARD COUNT = ****.

        See bulk data card description in Section 2.4.

316 ***  USER FATAL MESSAGE 316, ILLEGAL DATA ON BULK DATA CARD ********. SORTED
         CARD COUNT = ****.

        See bulk data card description in Section 2.4.

317 ***  USER FATAL MESSAGE 317, BAD DATA OR FORMAT OR NONUNIQUE NAME DTI ****
         SORTED CARD COUNT = ****.

        See bulk data card description in Section 2.4.

318 ***  SYSTEM FATAL MESSAGE 318, NO ROOM IN /XDPL/ FOR DTI ****.

        Overflow of the Data Pool Table. See Section 2 of the Programmer's
        Manual.

319 ***  SYSTEM FATAL MESSAGE 319, IFP READING EOF ON NPTP.

        Unexpected EOF encountered while attempting to read a card image.

320 ***  USER FATAL MESSAGE 320, IFP ERROR ****** LAST CARD PROCESSED IS ******.
         SORTED CARD COUNT = ****.

        Code error in IFP or XSORT.

321 ***  USER FATAL MESSAGE 321, NONUNIQUE PARAM NAME *****.

        The names of all parameters must be unique.

322 ***  SYSTEM FATAL MESSAGE 322, ILLEGAL ENTRY TO IFS1P.

        IFP code error detected in IFS1P, IFS2P, IFS3P, IFS4P, or IFS5P.

324 ***  USER WARNING MESSAGE 324, BLANK CARD(S) IGNORED.

        Blank bulk data cards are ignored by NASTRAN.

325 ***  USER FATAL MESSAGE 325, BAD DATA OR FORMAT OR NONUNIQUE NAME. DMI
         ****** SORTED CARD COUNT = ****.

        See bulk data card description in Section 2.4.

326 ***  SYSTEM FATAL MESSAGE 326, NO ROOM IN /XDPL/ FOR DMI ******.

        Overflow of the Data Pool Table. See Section 2 of the Programmer's
        Manual.

327 ***  USER FATAL MESSAGE 327, BAD DATA OR FORMAT OR NONUNIQUE NAME. DMIG
         ****** SORTED CARD COUNT = ****.

        See bulk data card description in Section 2.4.

329 ***  USER FATAL MESSAGE 329, ONLY ONE (1) AXIC CARD ALLOWED.

        See bulk data card description in Section 2.4.

330 ***  SYSTEM FATAL MESSAGE 330, NO ROOM IN CORE FOR PARAM CARDS.

        Change overlay or increase core size.

331 ***  USER FATAL MESSAGE 331, IMPROPER PARAM CARD ******, SORTED CARD COUNT =
         ****.

        See bulk data card description in Section 2.4.

332 ***  USER FATAL MESSAGE 332, AXIC CARD REQUIRED.

        The presence of any conical shell data cards requires the presence of
        an AXIC card. See the AXIC bulk data card description in Section 2.4.

333 ***  USER FATAL MESSAGE 333, UNABLE TO SORT ******** MULTI-ENTRY CARD DATA
         IN SUBROUTINE IFP DUE TO INSUFFICIENT CORE. ADDITIONAL CORE REQUIRED =
         ********** WORDS.

        Either increase the core or manually sort multi-entry data cards
        (CROD, PTRMEM, etc.).

334 ***  USER INFORMATION MESSAGE 334, ******** MULTI-ENTRY CARD DATA ARE NOT
         SORTED ON THEIR {ELEMENT/PROPERTY} IDS. SUBROUTINE IFP WILL SORT THE
         DATA.

335 ***  USER FATAL MESSAGE 335, NONUNIQUE {ELEMENT/PROPERTY} ID ********
         ENCOUNTERED IN ******** MULTI-ENTRY CARD DATA.

        Element and property identification numbers in multi-entry bulk data
        cards (CROD, PTRMEM, etc.) must be unique integers.

336 ***  USER FATAL MESSAGE 336, RFORCE DATA IN SET NO. ******** CONTAINS
         ILLEGAL DIRECTION FOR AXISYMMETRIC PROBLEM.

        Only the z component of the rotation direction vector can be defined.
        See the RFORCE data card description for details.

337 ***  USER FATAL MESSAGE 337, BOTH AXIC AND AXIF CARDS USED IN BULK DATA.

        Axisymmetric structural problems and hydroelastic problems are
        entirely different and AXIC and AXIF cards are mutually exclusive in
        the Bulk Data Deck.

338 ***  USER FATAL MESSAGE 338, AXISYMMETRIC CARD REQUIRED IN CASE CONTROL
         DECK.

        An AXIC or AXIF card was found in the Bulk Data Deck but the required
        AXISYMMETRIC card was omitted from the Case Control Deck.

339 ***  USER FATAL MESSAGE 339, ILLEGAL USE OF AXISYMMETRIC CARD IN CASE
         CONTROL DECK.

        An AXISYMMETRIC card was used in Case Control Deck but neither an
        AXIC nor an AXIF card was present in the Bulk Data Deck.

340 ***  USER FATAL MESSAGE 340, PARAM CARDS REQUIRED BY {DISP/AERO} RIGID
         FORMAT **** NOT FOUND IN BULK DATA.

        Refer to the description of the rigid formats in Volume II for the
        PARAM card parameters required by the rigid format indicated.

341 ***  USER FATAL MESSAGE 341, LMODES OR HFREQ/LFREQ PARAM REQUIRED BY
         {DISP/AERO} RIGID FORMAT **** NOT IN BULK DATA OR TURNED OFF.

        The modal frequency range or the number of modes required for a modal
        analysis problem was incorrectly specified.

342 ***  USER FATAL MESSAGE 342, LMODES PARAM FOUND IN BULK DATA WITH HFREQ OR
         LFREQ.

        Only one or the other of the two methods must be used to specify the
        range of modes to be used in a modal analysis problem.

343 ***  USER FATAL MESSAGE 343, NODJE PARAM SPECIFIED FOR AERO RIGID FORMAT
         BUT P1, P2, OR P3 OMITTED.

        A tape operation parameter required by the INPUTT2 module was
        missing.

344 ***  USER WARNING MESSAGE 344, P1, P2, OR P3 PARAM FOUND IN BULK DATA BUT
         NODJE MISSING OR TURNED OFF.

345 ***  USER FATAL MESSAGE 345, CTYPE OR NSEGS PARAM REQUIRED BY DISPLACEMENT
         RIGID FORMAT **** MISSING OR INCORRECT.

346 ***  USER FATAL MESSAGE 346, KINDEX PARAM REQUIRED BY DISPLACEMENT RIGID
         FORMAT 15 MISSING OR TURNED OFF.

        The harmonic index must be specified for problems involving normal
        modes with cyclic symmetry.

347 ***  USER FATAL MESSAGE 347, DYNAMIC PRESSURE (Q) PARAM REQUIRED BY AERO
         RIGID FORMAT 11 NOT IN BULK DATA.

348 ***  USER FATAL MESSAGE 348, FIRST CHARACTER ON CARD IS NUMERIC. INCORRECT
         FORMAT OR INCORRECT CONTINUATION ON PREVIOUS CARD.

        Check card above message or preceding one for format errors.

349 ***  USER FATAL MESSAGE 349, PLOT COMMAND **** NOT RECOGNIZED. CHECK
         SPELLING AND FORMAT ON THIS CARD AND CONTINUATION ON PREVIOUS ONE.

350 ***  USER WARNING MESSAGE 350, ONLY NASTRAN GENERAL PURPOSE PLOTTER IS
         SUPPORTED.

        SC and CALCOMP plotters are no longer supported. Plotter will default
        to NASTPLT for the run.

351 ***  USER FATAL MESSAGE 351, KEYWORD **** NOT FOUND.
(1)

        A keyword required on the preceding plot command card was not
        present.

351 ***  USER FATAL MESSAGE 351, KEYWORD **** NOT RECOGNIZED.
(2)

        The indicated keyword on the preceding card was not recognized.

352 ***  USER FATAL MESSAGE 352, COORDINATE AXES INCORRECTLY DEFINED.

        The coordinate axes for the plot are incorrectly specified on the
        preceding AXES or PLOT card.

353 ***  USER FATAL MESSAGE 353, INCORRECT FORMAT.

        The format of the preceding plot control card is incorrect. Refer to
        Section 4.2 for the correct format.

354 ***  USER WARNING MESSAGE 354, **** IDENTIFICATION NUMBER NOT DEFINED.

        A required SET, ORIGIN, PEN, DENSITY, or SYMBOL identification number
        was not specified. Default will be used.

355 ***  USER FATAL MESSAGE 355, DATA TYPE IS INCORRECT.

        The type of a parameter value was incorrectly specified on the
        previous card.

356 ***  USER FATAL MESSAGE 356, ONE OR MORE REQUIRED REAL VALUES MISSING.

357 ***  USER WARNING MESSAGE 357, CAMERA OPTION NOT SPECIFIED.

358 ***  USER FATAL MESSAGE 358, THRU MUST BE PRECEDED AND FOLLOWED BY INTEGER
         VALUES.

359 ***  USER FATAL MESSAGE 359, THRU RANGE OVERLAPS RANGE OF PREVIOUS THRU.

360 ***  USER FATAL MESSAGE 360, ONLY DEFORMATION VALID WITH ****.

        The keywords VELOCITY or ACCELERATION may not be used with keywords
        STATIC, MODAL, or CMODAL.

361 ***  USER FATAL MESSAGE 361, CCONEAX ID = ****. OUT OF 1 TO 9999 PERMISSIBLE
         RANGE.

362 ***  USER FATAL MESSAGE 362, MINIMUM PROBLEM REQUIRES **** CARD. NONE FOUND.
(1)

362 ***  USER FATAL MESSAGE 362, MINIMUM PROBLEM REQUIRES ****, **** OR ****
(2)      CARD. NONE FOUND.

363 ***  USER FATAL MESSAGE 363, RAN OUT OF OPEN CORE READING **** FILE IN ****
         SUBROUTINE.

        Increase Region Size, Field Length, HICORE allocation, or the length
        of the open core COMMON block, depending on the machine being used.

364 ***  USER FATAL MESSAGE 364, HARMONIC NUMBER **** ON **** CARD. OUT OF 0 TO
         **** ALLOWABLE RANGE.

365 ***  USER FATAL MESSAGE 365, RING ID **** ON **** CARD OUT OF 1 TO 999999
         ALLOWABLE RANGE.

366 ***  USER FATAL MESSAGE 366, SPCAX OR MPCAX CARD HAS SETID = 101 OR 102. 101
         AND 102 ARE SYSTEM ID-S RESERVED FOR SINE AND COSINE SETS.

367 ***  USER FATAL MESSAGE 367, COMPONENT SPECIFICATION **** ON **** CARD IS
         INCORRECT.

368 ***  USER FATAL MESSAGE 368, RINGAX CARD WITH RING ID = **** HAS A ZERO
         RADIUS SPECIFIED.

501 ***  SYSTEM FATAL MESSAGE 501, MED TABLE INCORRECT FOR THIS SOLUTION.

        Input to subroutine XSBSET is incorrect. Look for format error in
        array SS.

502 ***  USER FATAL MESSAGE 502, ILLEGAL SUBSET NUMBER FOR THIS SOLUTION.

        You specified an incorrect subset number on SOL control card.

503 ***  USER FATAL MESSAGE 503, ILLEGAL SOLUTION NUMBER.

        You specified an incorrect solution number on SOL control card.

504 ***  USER FATAL MESSAGE 504, CANNOT CHANGE FROM SOLUTION *** TO SOLUTION
         ***.

505 ***  USER FATAL MESSAGE 505, CONTROL CARD **** IS ILLEGAL.

        The card preceding Message 505 cannot be processed correctly.

506 ***  USER FATAL MESSAGE 506, CONTROL CARD **** DUPLICATED.

        The card preceding Message 506 cannot be input more than once.

507 ***  USER FATAL MESSAGE 507, ILLEGAL SPECIFICATION OR FORMAT ON PRECEDING
         CARD.

508 ***  USER FATAL MESSAGE 508, PROBLEM TAPE MUST BE ON PHYSICAL TAPE FOR
         CHECKPOINTING.

        You requested checkpointing (that is, CHKPNT YES) but did not specify
        NPTP with the FILES keyword on the NASTRAN card. Therefore, the
        Problem Tape must be set up on tape drive.

509 ***  USER FATAL MESSAGE 509, WRONG OLD PROBLEM TAPE MOUNTED. OLD PROBLEM
         TAPE ID = ********,********,**/**/**, REEL NO. = ***.

        The Old Problem Tape identification does not match the identification
        on the RESTART card.

510 ***  SYSTEM FATAL MESSAGE 510, CHECKPOINT DICTIONARY EXCEEDS CORE SIZE -
         REMAINING RESTART CARDS IGNORED.

        You have run out of open core. If approach is DMAP, try putting
        restart deck before DMAP sequence. If this does not solve the
        problem, or if approach is not DMAP, then you must decrease the size
        of the restart deck.

511 ***  SYSTEM FATAL MESSAGE 511, DMAP SEQUENCE EXCEEDS CORE SIZE - REMAINING
         DMAP INSTRUCTIONS IGNORED.

        You have run out of open core. Split the DMAP sequence somewhere
        prior to where message 511 was printed out.

512 ***  USER FATAL MESSAGE 512, OLD PROBLEM TAPE IS MISSING AND IS NEEDED FOR
         RESTART.

        The Problem Tape corresponding to identification on RESTART control
        card must be set up on the unit assigned to the Old Problem Tape.

513 ***  USER FATAL MESSAGE 513, ALTER SEQUENCE NUMBERS ARE OUT OF ORDER.

514 ***  USER FATAL MESSAGE 514, ENDALTER CARD IS MISSING.

        ALTER deck must end with the ENDALTER control card.

515 ***  USER FATAL MESSAGE 515, END INSTRUCTION MISSING IN DMAP SEQUENCE.

        DMAP sequence must end with the END control card.

516 ***  USER FATAL MESSAGE 516, UMF TAPE MUST BE MOUNTED ON PHYSICAL TAPE
         DRIVE.

        The UMF tape must be set up on the unit assigned to it as UMF was not
        specified with the FILES keyword on the NASTRAN card.

517 ***  USER FATAL MESSAGE 517, WRONG UMF TAPE MOUNTED - TAPE ID = ****.

        The tape identification number on the UMF tape does not match the
        tape identification number on the UMF control card.

518 ***  USER FATAL MESSAGE 518, CANNOT USE UMF TAPE FOR RESTART.

519 ***  USER FATAL MESSAGE 519, ID CARD MUST PRECEDE ALL OTHER CONTROL CARDS.

520 ***  USER FATAL MESSAGE 520, CONTROL CARD **** IS MISSING.

521 ***  USER FATAL MESSAGE 521, SPECIFY A SOLUTION OR A DMAP SEQUENCE BUT NOT
         BOTH.

        You must select a DMAP sequence from the library either by using the
        SOL control card or by supplying your own DMAP sequence. Do one or
        the other, but not both.

522 ***  USER FATAL MESSAGE 522, NEITHER A SOL CARD NOR A DMAP SEQUENCE WAS
         INCLUDED.

        See Message 521.

523 ***  USER FATAL MESSAGE 523, ENDALTER CARD OUT OF ORDER.

        The ENDALTER control card must be preceded by the ALTER deck.

524 ***  SYSTEM FATAL MESSAGE 524, ALTERNATE RETURN TAKEN WHEN OPENING FILE
         ****.

        This occurs if the file name is not in the FIST or the end of tape
        was reached while writing on the file. The file name should
        correspond to one of the permanent entries in the FIST.

525 ***  SYSTEM FATAL MESSAGE 525, ILLEGAL FORMAT ENCOUNTERED WHILE READING FILE
         ****.

        File is not in the correct format. Either the wrong tape was mounted
        or it does not contain what you think it should.

526 ***  USER FATAL MESSAGE 526, CHECKPOINT DICTIONARY OUT OF SEQUENCE -
         REMAINING RESTART CARDS IGNORED.

        The checkpoint dictionary which follows the RESTART control card must
        be sequenced according to first number on each card.

527 ***  USER FATAL MESSAGE 527, DUPLICATE SUBSET NUMBER *****.

528 ***  USER WARNING MESSAGE 528, FACTOR FMID IN FLFACT SET **** DOES NOT LIE
         BETWEEN F1 AND FNF. IT IS BEING RESET TO (F1 + FNF)/2.0.

        The error may be either on a FLFACT card or on an AEFACT card.

529 ***  USER FATAL MESSAGE 529, MISSING CEND CARD.

601 ***  USER FATAL MESSAGE 601, THE KEYWORD ON THE ABOVE CARD IS ILLEGAL OR
         MISSPELLED. SEE THE FOLLOWING LIST FOR LEGAL KEY WORDS.

        Case Control expects each card to begin with a keyword (usually 4
        characters in length). Your card does not. User Message 612 will list
        the legal keywords along with a brief description of function. To
        remove the error, consult Message 612 of NASTRAN Case Control card
        descriptions, Section 2.3, and spell your request correctly.

602 ***  USER WARNING MESSAGE 602, TWO OR MORE OF THE ABOVE CARD TYPES DETECTED
         WHERE ONLY ONE IS LEGAL. THE LAST FOUND WILL BE USED.

        Remove the card with the duplicate meaning. Note that some cards have
        alternate forms.

603 ***  USER FATAL MESSAGE 603, THE ABOVE CARD DOES NOT END PROPERLY. COMMENTS
         SHOULD BE PRECEDED BY A DOLLAR SIGN.

        Case Control cards of the form, name = value, should not contain more
        than one value. Refer to Section 2.3 for a complete description of
        the card or precede your comments with a dollar sign.

604 ***  USER FATAL MESSAGE 604, THE ABOVE CARD HAS A NONINTEGER IN AN INTEGER
         FIELD.

        Consult Section 2.3 for legal values.

605 ***  USER FATAL MESSAGE 605, A SYMSEQ OR SUBSEQ CARD APPEARS WITHOUT A
         SYMCOM OR SUBCOM CARD.

        SYMSEQ or SUBSEQ cards must appear in a subcase defined by a SYMCOM
        or SUBCOM card. Check your Case Control Deck order and relabel your
        combination subcase.

606 ***  USER FATAL MESSAGE 606, A REQUEST FOR TEMPERATURE DEPENDENT MATERIALS
         OCCURS AT THE SUBCASE LEVEL. ONLY ONE ALLOWED PER PROBLEM.

        Only one temperature field for materials is allowed per NASTRAN run.
        The last specified will be used for the entire run. If additional
        ones are desired, a modified restart is in order.

607 ***  USER FATAL MESSAGE 607, A REPCASE SUBCASE MUST BE PRECEDED BY A SUBCASE
         OR SYM SUBCASE.

        A REPCASE subcase is an attempt to re-output the previously computed
        case; therefore it cannot be the first subcase.

608 ***  USER FATAL MESSAGE 608, THE SET ID SPECIFIED ON THE ABOVE CARD MUST BE
         DEFINED PRIOR TO THIS CARD.

        Set identification numbers must be specified prior to their use.
        Also, sets specified within a subcase die at the end of the subcase.
        Redefine set (or define set) or move set out of subcase.

609 ***  USER FATAL MESSAGE 609, SUBCASE DELIMITER CARDS MUST HAVE A UNIQUE
         IDENTIFYING INTEGER.

        Subcase type cards must have an identifying integer. These numbers
        must be strictly increasing. Renumber your subcase cards. The use of
        a non-blank delimiter (for example, "=") will also cause this message
        to occur.

610 ***  USER WARNING MESSAGE 610, NO SET ID SPECIFIED. ALL WILL BE ASSUMED.

611 ***  USER FATAL MESSAGE 611, TEN CARDS HAVE ILLEGAL KEYWORDS. NASTRAN
         ASSUMES BEGIN BULK CARD IS MISSING. IT WILL NOW PROCESS YOUR BULK DATA.

        Only ten key words may be misspelled. A common source of this error
        may be the omission of the OUTPUT(PLOT), OUTPUT(XYOUT), or
        OUTPUT(XYPLOT) delimiter cards.

612 ***  USER FATAL MESSAGE 612, --LIST OF LEGAL CASE CONTROL MNEMONICS.

        This message is caused by Messages 601 or 611.

613 ***  USER FATAL MESSAGE 613, THE ABOVE SET CONTAINS 'EXCEPT' WHICH IS NOT
         PRECEDED BY 'THRU'.

        Only identification numbers included in THRU statements may be
        excepted. Simplify your SET request.

614 ***  USER FATAL MESSAGE 614, THE ABOVE SET IS INCORRECTLY SPECIFIED. CHECK
         FORMAT ON THIS OR PREVIOUS CARD.

        The grammar of the SET list is incorrect or a continuation card is
        missing.

615 ***  USER FATAL MESSAGE 615, AN IMPROPER OR NO NAME GIVEN TO THE ABOVE SET.

        SET lists must have integer names. This SET list does not have one.
        SET 10 = is the correct format. Give the SET a correct integer name.

616 ***  USER FATAL MESSAGE 616, ELEMENT IN THRU RANGE LIES IN RANGE OF PREVIOUS
         THRU OR EXCEPT. MISSING ELEMENT OR INCORRECT USE OF THRU.

        EXCEPT in SET list can only be followed by integers.  An integer
        larger than THRU pair terminates THRU. Either list exceptions
        explicitly, use two THRUs, or terminate first THRU.

617 ***  USER FATAL MESSAGE 617, INCORRECT OR MISSING VALUE ON CASE CONTROL
         CARD. CHECK FOR CORRECT CARD FORMAT.

        Most integer values in Case Control must be positive. The above card
        either has a negative integer or a BCD value in place of a positive
        integer. Check the Case Control Deck documentation in Section 2.3 for
        the proper card format.

618 ***  USER FATAL MESSAGE 618, PLOTTER OUTPUT IS REQUESTED BUT THE PROPER PLOT
         TAPE IS NOT A PHYSICAL TAPE.

        Neither PLT1 or PLT2 is a physical tape. Remove the plot control
        packet or set up the appropriate tape.

619 ***  USER WARNING MESSAGE 619, SET MEMBER *** BELONGS TO *** THRU ***.

        A set member is already included in a THRU. The individual member
        will be absorbed in the THRU.

620 ***  USER WARNING MESSAGE 620, SET MEMBER *** IS DUPLICATED IN SET LIST.

        A set member is listed twice. The second reference will be deleted.

621 ***  USER WARNING MESSAGE 621, INTERVAL *** THRU *** OVERLAPS INTERVAL ***
         THRU ***. THE MAXIMUM INTERVAL WILL BE USED.

622 ***  USER FATAL MESSAGE 622, REAL VALUES NOT ALLOWED IN A THRU SEQUENCE.

623 ***  USER FATAL MESSAGE 623, UNEXPECTED END-OF-RECORD ON CASE CONTROL CARD.
         CHECK FOR CORRECT CARD FORMAT.

624 ***  USER FATAL MESSAGE 624, BEGIN BULK CARD NOT FOUND.

625 ***  USER FATAL MESSAGE 625, TOO LARGE ID ON PRECEDING SUBCASE TYPE CARD.
         ALL ID-S MUST BE LESS THAN 99,999,999.

        Reduce the size of your subcase Identification number. Note also that
        BCD subcase identification numbers are not legal.

626 ***  USER FATAL MESSAGE 626, VALUES IN EXCEPT MUST BE SPECIFIED IN ASCENDING
         ORDER.

627 ***  USER FATAL MESSAGE 627, THE ABOVE SUBCASE HAS BOTH A STATIC LOAD AND A
         REAL EIGENVALUE METHOD SELECTION -- REMOVE ONE.

        Rigid Formats 5 and 13 require static load and METHOD selections in
        the Case Control Deck. Both a load and a METHOD selection cannot take
        place in the same subcase. See Sections 2.5.4 and 2.13.4 in Volume
        II, respectively, for subcase requirements.

628 ***  USER FATAL MESSAGE 628, THERMAL, DEFORMATION, AND EXTERNAL LOADS CANNOT
         HAVE THE SAME SET IDENTIFICATION NUMBER.

        Set IDs specified on the LOAD, TEMP(LOAD), and DEFORM Case Control
        cards must be unique.

629 ***  USER WARNING MESSAGE 629, ECHO CARD HAS REPEATED OR UNRECOGNIZABLE
         SPECIFICATION DATA--REPEATED SPECIFICATIONS WILL BE IGNORED,
         UNRECOGNIZABLE SPECIFICATIONS WILL BE TREATED AS SORT.

630 ***  USER WARNING MESSAGE 630, ECHO CARD WITH -NONE- SPECIFICATION HAS
         ADDITIONAL SPECIFICATIONS WHICH WILL BE IGNORED.

631 ***  USER FATAL MESSAGE 631, PLOT AND/OR SET COMMAND CARD MISSING FROM
         STRUCTURE PLOTTER OUTPUT PACKAGE.

        At least one SET and one PLOT card must he included after an
        OUTPUT(PLOT) card.

632 ***  USER FATAL MESSAGE 632, XYPLOT COMMAND CARDS FOUND IN STRUCTURE PLOTTER
         OUTPUT PACKAGE.

        Plot command cards intended for an OUTPUT(XYPLOT) or OUTPUT(XYOUT)
        package may not be used in an OUTPUT(PLOT) package. Check for missing
        OUTPUT(XYPLOT) or OUTPUT(XYOUT) card.

651 ***  SYSTEM FATAL MESSAGE 651, LOGIC ERROR IN SUBROUTINE IFP1B WHILE
         PROCESSING SET DATA ON **** FILE.

675 ***  USER FATAL MESSAGE 675, ABOVE CARD DOES NOT BEGIN WITH A NONNUMERIC
         WORD.

676 ***  USER FATAL MESSAGE 676, **** IS NOT RECOGNIZED AS AN XYPLOT COMMAND
         CARD OR PARAMETER.

677 ***  USER FATAL MESSAGE 677, ILLEGAL VALUE SPECIFIED.

678 ***  USER FATAL MESSAGE 678, *** CONTRADICTS PREVIOUS DEFINITION.

679 ***  USER FATAL MESSAGE 679, *** DELIMITER ILLEGALLY USED.

680 ***  USER FATAL MESSAGE 680, **** ILLEGAL IN STATEMENT.

681 ***  USER FATAL MESSAGE 681, **** IS ILLEGAL IN STATEMENT.

682 ***  USER FATAL MESSAGE 682, **** IS ILLEGAL IN STATEMENT.

683 ***  USER FATAL MESSAGE 683, TOO MANY SUBCASES. MAXIMUM = 200 ON ANY ONE XY-
         OUTPUT COMMAND CARD.

684 ***  USER FATAL MESSAGE 684, SUBCASE-ID IS LESS THAN 1 OR IS NOT IN
         ASCENDING ORDER.

685 ***  USER FATAL MESSAGE 685, **** = POINT OR ELEMENT ID IS ILLEGAL (LESS
         THAN 1).

686 ***  USER FATAL MESSAGE 686, NEGATIVE OR ZERO COMPONENTS ARE ILLEGAL.

687 ***  USER FATAL MESSAGE 687, ALPHA-COMPONENTS ARE NOT PERMITTED FOR STRESS
         OR FORCE XY-OUTPUT REQUESTS.

        An XYPLOT command for stresses and forces cannot have alphabetic
        characters in the item code. See the tables in Section 4.3.2.5 for
        the proper format.

688 ***  USER FATAL MESSAGE 688, **** COMPONENT NAME NOT RECOGNIZED.

689 ***  USER FATAL MESSAGE 689, LAST CARD ENDED WITH A DELIMITER BUT NO
         CONTINUATION CARD WAS PRESENT.

690 ***  USER FATAL MESSAGE 690, TYPE OF CURVE WAS NOT SPECIFIED. (E.G.,
         DISPLACEMENT, STRESS, ETC.)

691 ***  USER FATAL MESSAGE 691, MORE THAN 2 OR UNEQUAL NUMBER OF COMPONENTS FOR
         IDENTIFICATION NUMBERS WITHIN A SINGLE FRAME.

692 ***  USER FATAL MESSAGE 692, XY-OUTPUT COMMAND IS INCOMPLETE.

693 ***  USER FATAL MESSAGE 693, INSUFFICIENT CORE FOR SET TABLE. AT LEAST ****
         MORE WORDS NEEDED.

694 ***  USER FATAL MESSAGE 694, AUTO OR PSDF REQUESTS MAY NOT USE SPLIT FRAME,
         THUS ONLY ONE COMPONENT PER ID IS PERMITTED.

695 ***  USER FATAL MESSAGE 695, COMPONENT VALUE = **** IS ILLEGAL FOR AUTO OR
         PSDF VECTOR REQUESTS.

696 ***  USER FATAL MESSAGE 696, COMPONENT VALUE = ******** IS ILLEGAL FOR
         VECTOR TYPE SPECIFIED.

697 ***  USER FATAL MESSAGE 697, XYPLOT, XYPRINT, XYPUNCH, XYPEAK, OR XYPAPLOT
(1)      CARD NOT FOUND IN XY PLOTTER OUTPUT PACKAGE.

697 ***  USER WARNING MESSAGE 697, SET **** NOT DEFINED. FIRST SET DEFINED WILL
(2)      BE USED.

698 ***  USER FATAL MESSAGE 698, NO SETS DEFINED FOR PLOTS.

699 ***  USER FATAL MESSAGE 699, **** ELEMENT IS INVALID.

        An element type was incorrectly specified on a plot SET card. Refer
        to subsection 4.2.2.4 for correct element type names.

700 ***  USER FATAL MESSAGE 700, SET **** REQUESTED ON {FIND/PLOT} CARD HAS NOT
         BEEN DEFINED.

702 ***  USER FATAL MESSAGE 702, PLOT FILE **** DOES NOT EXIST.

703 ***  USER FATAL MESSAGE 703, SET **** REQUESTED ON FIND CARD NOT IN GPSETS
         FILE.

969 ***  USER FATAL MESSAGE 969, COMPONENT VALUE = **** IS ILLEGAL FOR VECTOR
         TYPE SPECIFIED.

975 ***  USER WARNING MESSAGE 975, XYTRAN DOES NOT RECOGNIZE **** AND IS
         IGNORING.

976 ***  USER WARNING MESSAGE 976, OUTPUT DATA BLOCK **** IS PURGED. XYTRAN WILL
         PROCESS ALL REQUESTS OTHER THAN PLOT.

977 ***  USER WARNING MESSAGE 977, FOLLOWING NAMED DATA BLOCK IS NOT IN SORT2
         FORMAT.

978 ***  USER WARNING MESSAGE 978, XYTRAN MODULE FINDS DATA BLOCK (****) PURGED,
         NULL, OR INADEQUATE, AND IS IGNORING XY-OUTPUT REQUEST FOR - **** -
         CURVES.

979 ***  USER WARNING MESSAGE 979, AN XY-OUTPUT REQUEST FOR POINT OR ELEMENT ID
         **** - **** - CURVE IS BEING PASSED OVER. THE ID COULD NOT BE FOUND IN
         DATA BLOCK ****.

980 ***  USER WARNING MESSAGE 980, INSUFFICIENT CORE TO HANDLE ALL DATA FOR ALL
         CURVES OF THIS FRAME ID = **** COMPONENT = **** DELETED FROM OUTPUT.

981 ***  USER WARNING MESSAGE 981, COMPONENT = **** FOR ID = **** IS TOO LARGE.
         THIS COMPONENTS CURVE NOT OUTPUT.

982 ***  USER WARNING MESSAGE 982, FORMAT OF SDR3 INPUT DATA BLOCK **** DOES NOT
         PERMIT SUCCESSFUL SORT2 PROCESSING.

983 ***  USER WARNING MESSAGE 983, SDR3 HAS INSUFFICIENT CORE TO PERFORM SORT2
         ON INPUT DATA BLOCK **** OR DATA BLOCK IS NOT IN CORRECT FORMAT.

984 ***  USER WARNING MESSAGE 984, SDR3 FINDS OUTPUT DATA BLOCK **** PURGED.

985 ***  USER WARNING MESSAGE 985, SDR3 FINDS SCRATCH **** PURGED.

986 ***  USER WARNING MESSAGE 986, INSUFFICIENT CORE FOR SDR3.

991 ***  USER WARNING MESSAGE 991, XYPLOT INPUT DATA FILE **** NOT FOUND. XYPLOT
         ABANDONED.

        The input data file probably has been purged and there were no plots
        to be done.

992 ***  USER WARNING MESSAGE 992, XYPLOT INPUT DATA FILE I.D. RECORDS TOO
         SHORT. XYPLOT ABANDONED.

        The input data file records have invalid word counts and further
        plotting is not feasible.

993 ***  USER WARNING MESSAGE 993, XYPLOT FOUND ODD NO. OF VALUES FOR DATA PAIRS
         IN FRAME ****, CURVE NO. ****. LAST VALUE IGNORED.

        May indicate a bad input file, but plotting continues.

994 ***  USER WARNING MESSAGE 994, XYPLOT OUTPUT FILE NAME **** NOT FOUND.
         XYPLOT ABANDONED.

        The PLT2 file required for plotting has not been properly set up and
        further plotting is useless.

997 ***  USER WARNING MESSAGE 997, NO. ***. FRAME NO. **** INPUT DATA
         INCOMPATIBLE. ASSUMPTIONS MAY PRODUCE INVALID PLOT.

        NO. *** may take any value from 1 to 4 with the following meanings:

        1. Specified X maximum equals X minimum. If this value is zero, then
        X maximum is set to 5.0 and X minimum to -5.0, otherwise 5 times the
        absolute value of X maximum is added to X maximum and subtracted from
        X minimum.

        2. Specified X maximum is smaller than X minimum. The values are
        reversed.

        3. Same meaning as number 1 except for Y maximum and Y minimum.

        4. Same meaning as number 2 except for Y maximum and Y minimum.

998 ***  SYSTEM WARNING MESSAGE 998, XYPLOT PLOTTER OR FRAME MAY NOT CHANGE FOR
         LOWER FRAME. XYPLOT ABANDONED.

        Camera option, size of paper, and plotter type must be the same for
        upper and lower frames.

=PAGE=
6.3  EXECUTIVE MODULE MESSAGES

1001  ***  SYSTEM FATAL MESSAGE 1001, OSCAR NOT FOUND IN DPL.

          OSCAR file not present (destroyed) in Data Pool Dictionary.

1002  ***  SYSTEM FATAL MESSAGE 1002, OSCAR CONTAINS NO MODULES.

          XSFA found no modules on OSCAR needing file allocation.

1003  ***  SYSTEM FATAL MESSAGE 1003, POOL COULD NOT BE OPENED.

          Data Pool File (POOL) not present (destroyed) in FIST.

1004  ***  SYSTEM FATAL MESSAGE 1004, ILLEGAL EOF ON POOL.

          End-of-file encountered before OSCAR file reached on Data Pool.

1011  ***  SYSTEM FATAL MESSAGE 1011, MD OR SOS TABLE OVERFLOW.

          Module description or serial OSCAR table overflowed.

1012  ***  SYSTEM FATAL MESSAGE 1012, POOL COULD NOT BE OPENED.

          Data Pool File (POOL) not present (destroyed) in FIST.

1013  ***  SYSTEM FATAL MESSAGE 1013, ILLEGAL EOR ON POOL.

          OSCAR record has illegal format.

1014  ***  SYSTEM FATAL MESSAGE 1014, POOL FILE MIS-POSITIONED.

          OSCAR (POOL) file not at position passed in XSFA calling sequence.

1021  ***  SYSTEM FATAL MESSAGE 1021, FIAT OVERFLOWED.

          FIAT /XFIAT/ Table overflowed; reduce number of logical files. See
          Section 2 of the Programmer's Manual.

1031  ***  SYSTEM FATAL MESSAGE 1031, DPL OVERFLOW.

          Data Pool Dictionary /XDPL/ overflowed; increase compiled size. See
          Section 2 of the Programmer's Manual.

1032  ***  SYSTEM FATAL MESSAGE 1032, POOL OR FILE BEING POOLED/UN-POOLED COULD
           NOT BE OPENED.

          Files not present (destroyed) in FIST.

1033  ***  SYSTEM FATAL MESSAGE 1033, ILLEGAL EOF ON FILE BEING POOLED.

          File being pooled has illegal format.

1034  ***  SYSTEM FATAL MESSAGE 1034, ILLEGAL EOR ON FILE BEING POOLED.

          File being pooled has illegal format (bad header).

1035  ***  SYSTEM FATAL MESSAGE 1035, EQUIV INDICATED, NONE FOUND.

          File (data block) equivalence not found as indicated by XSFA.

1041  ***  SYSTEM FATAL MESSAGE 1041, OLD/NEW POOL COULD NOT BE OPENED.

          Files not present (destroyed) in FIST.

1051  ***  SYSTEM FATAL MESSAGE 1051, FIAT OVERFLOW.

          FIAT /XFIAT/ overflowed; reduce number of logical files. See
          Section 2 of the Programmer's Manual.

1101  ***  USER FATAL MESSAGE 1101, COULD NOT OPEN FILE NAMED ********.

          Data block has not been generated.

1102  ***  SYSTEM FATAL MESSAGE 1102, COULD NOT OPEN FILE NAMED ********.

          Problem Tape (NPTP) or Pool Table (POOL) File linkage is broken.
          Look for error in /XFIST/, /XPFIST/, or /XXFIAT/.

1103  ***  SYSTEM FATAL MESSAGE 1103, UNABLE TO POSITION DATA POOL FILE
           CORRECTLY.

          Contents of /XDPL/ do not correspond to contents of POOL file.

1104  ***  SYSTEM FATAL MESSAGE 1104, FDICT TABLE IS INCORRECT.

          Subroutine XCHK is not generating FDICT correctly.

1105  ***  USER FATAL MESSAGE 1105, CANNOT FIND DATA BLOCK NAMED ******** HEADER
           RECORD = ********.

          Data block name or equivalenced data block name must match header
          record.

1106  ***  USER FATAL MESSAGE 1106, CHECKPOINT DICTIONARY OVERFLOWED THERE IS NO
           MORE CORE AVAILABLE.

          Restart problem from this point with dictionary available.

1107  ***  SYSTEM FATAL MESSAGE 1101, CANNOT FIT DATA BLOCK NAMED ******** ON
           TWO PROBLEM TAPE REELS.

          Use full tape reels for Problem Tape.

1108  ***  SYSTEM FATAL MESSAGE 1108, PURGE TABLE OVERFLOWED.

          Reduce the number of data blocks being checkpointed at one time by
          replacing a single CHKPNT instruction with two CHKPNT instructions.

1109  ***  SYSTEM FATAL MESSAGE 1109, CANNOT FIND DATA BLOCK NAMED NXPTDC HEADER
           RECORD = ********.

          Problem Tape is not positioned correctly for reading NXPTDC.
          Problem is in subroutine which previously wrote NXPTDC onto Problem
          Tape. Suspect subroutine is XGPI, XCEI, or XCHK.

1126  ***  SYSTEM FATAL MESSAGE 1126, ADDRESS OF BUFFER LESS THAN ADDRESS OF
           /XNSTRN/.

          Highly unlikely. Program bug or machine error.

1127  ***  SYSTEM FATAL MESSAGE 1127, BUFFER ASSIGNED EXTENDS INTO MASTER INDEX
           AREA.

          Calling program bug in buffer allocation or first word of /SYSTEM/
          has been altered.

1128  ***  SYSTEM FATAL MESSAGE 1128, ON AN OPEN CALL WITHOUT REWIND, THE BLOCK
           NUMBER READ DOES NOT MATCH EXPECTED VALUE.

          Probably I/O Error.

1129  ***  SYSTEM FATAL MESSAGE 1129, ON A CALL WRITE THE WORD COUNT IS
           NEGATIVE.

          Definite calling program error.

1130  ***  SYSTEM FATAL MESSAGE 1130, ON A CALL READ THE CONTROL WORD AT WHICH
           THE FILE IS POSITIONED IS NOT ACCEPTABLE.

          Attempt to read string formatted record which is not allowed.

1131  ***  SYSTEM FATAL MESSAGE 1131, LOGICAL RECORD TRAILER NOT RECOGNIZABLE AS
           SUCH.

          Probable GINO bug or hardware error.

1132  ***  SYSTEM FATAL MESSAGE 1132, UNRECOGNIZABLE CONTROL WORD DURING
           PROCESSING OF A BCKREC CALL.

          Probable GINO bug or hardware error.

1133  ***  SYSTEM FATAL MESSAGE 1133, AFTER A POSITIONING CALL TO IO6600, DURING
           PROCESSING OF A BCKREC CALL THE BLOCK READ WAS NOT THE EXPECTED ONE.

          Probable IO6600 bug or possible I/O error.

1134  ***  SYSTEM FATAL MESSAGE 1134, CALL SKPFIL IN A FORWARD DIRECTION ON A
           FILE NOT OPENED FOR OUTPUT IS NOT SUPPORTED.

1135  ***  SYSTEM FATAL MESSAGE 1135, FILPOS WAS CALLED ON A FILE OPENED FOR
           OUTPUT.

1136  ***  SYSTEM FATAL MESSAGE 1136, ENDPUT WAS CALLED WITH BLOCK (8) = -1.

          Most likely PUTSTR was not called first.

1137  ***  SYSTEM FATAL MESSAGE 1137, MORE TERMS WRITTEN IN STRING THAN WERE
           AVAILABLE TO WRITE.

          Most likely subroutine logic error.

1138  ***  SYSTEM FATAL MESSAGE 1138, CURRENT BUFFER POINTER EXCEEDS LAST DATA
           WORD IN BLOCK.

          Probably a bug in PUTSTR in the computation of the number of terms
          available to write in a string.

1139  ***  SYSTEM FATAL MESSAGE 1139, ON AN INITIAL CALL TO GETSTR, THE RECORD
           IS NOT POSITIONED AT THE COLUMN HEADER.

          Either the record is not a string formatted record, or the calling
          routine has not made a proper sequence of GETSTR, ENDGET calls.

1140  ***  SYSTEM FATAL MESSAGE 1140, STRING DEFINITION WORD NOT RECOGNIZABLE.

          Probable cause is a failure to call ENDGET to complete processing
          of the previous string.

1141  ***  SYSTEM FATAL MESSAGE 1141, FIRST WORD OF A DOUBLE PRECISION STRING IS
           NOT ON A DOUBLE PRECISION BOUNDARY.

          This error is probably due to a bug in any of PUTSTR, OPEN, or
          NASTIO, all of which have responsibility for ensuring proper
          alignment.

1142  ***  SYSTEM FATAL MESSAGE 1142, CURRENT BUFFER POINTER IS BEYOND RANGE OF
           INFORMATION IN BUFFER.

          Either an attempt to read beyond end-of-information or a GINO logic
          bug.

1143  ***  SYSTEM FATAL MESSAGE 1143, ON AN INITIAL CALL TO GETSTR, THE FILE IS
           NOT POSITIONED AT AN ACCEPTABLE POINT.

          File should be positioned at the beginning of record or at
          end-of-file.

1144  ***  SYSTEM FATAL MESSAGE 1144, END-OF-SEGMENT CONTROL WORD SHOULD HAVE
           IMMEDIATELY PRECEDED CURRENT POSITION AND IT DID NOT.

          GINO logic error.

1145  ***  SYSTEM FATAL MESSAGE 1145, COLUMN TRAILER NOT FOUND.

          Previous record to be read backwards is not a string formatted
          record.

1146  ***  SYSTEM FATAL MESSAGE 1146, PREVIOUS RECORD TO BE READ BACKWARDS WAS
           NOT WRITTEN WITH STRING TRAILERS.

1147  ***  SYSTEM FATAL MESSAGE 1147, STRING RECOGNITION WORD NOT RECOGNIZED.

          A subroutine may not have called GETSTR to indicate completion of
          processing of previous string or a bug in GETSTR logic.

1148  ***  SYSTEM FATAL MESSAGE 1148, RECORD CONTROL WORD NOT IN EXPECTED
           POSITION.

          Logic error in GETSTR or PUTSTR when string was written.

1149  ***  SYSTEM FATAL MESSAGE 1149, RECTYP WAS CALLED FOR A FILE OPENED FOR
           OUTPUT.

          Not allowed.

1150  ***  SYSTEM FATAL MESSAGE 1150, RECTYP MUST BE CALLED WHEN THE FILE IS
           POSITIONED AT THE BEGINNING OF A RECORD.

1151  ***  SYSTEM FATAL MESSAGE 1151, ON A CALL TO OPEN THE BUFFER ASSIGNED
           OVERLAPS A PREVIOUSLY ASSIGNED BUFFER.

1152  ***  SYSTEM FATAL MESSAGE 1152, CALL TO OPEN FOR AN ALREADY OPEN FILE.

1153  ***  SYSTEM FATAL MESSAGE 1153, FILE NOT OPEN.

1154  ***  SYSTEM FATAL MESSAGE 1154, GINO REFERENCE NAME NOT IN FIST OR FILE
           NOT OPEN.

1155  ***  SYSTEM FATAL MESSAGE 1155, CALL TO GETSTR OCCURRED WHEN THE FILE WAS
           POSITIONED AT END-OF-FILE.

1156  ***  SYSTEM FATAL MESSAGE 1156, ATTEMPTED TO WRITE ON AN INPUT FILE.

1157  ***  SYSTEM FATAL MESSAGE 1157, ATTEMPTED TO READ FROM AN OUTPUT FILE.

1158  ***  SYSTEM FATAL MESSAGE 1158, A CALL TO BLDPK OR PACK IN WHICH EITHER
           TYPIN OR TYPOUT IS OUT OF RANGE.

1159  ***  SYSTEM FATAL MESSAGE 1159, ROW POSITIONS OF ELEMENTS FURNISHED TO
           ZBLPKI OR BLDPKI ARE NOT IN MONOTONIC INCREASING SEQUENCE.

1160  ***  SYSTEM FATAL MESSAGE 1160, ON A CALL TO BLDPKN, FILE NAME DOES NOT
           MATCH PREVIOUS CALLS.

          BLDPK was not called prior to a call to BLDPKN.

1161  ***  SYSTEM FATAL MESSAGE 1161, A CALL TO INTPK OR UNPACK IN WHICH TYPOUT
           IS OUT OF RANGE.

1162  ***  SYSTEM FATAL MESSAGE 1162, ON AN ATTEMPT TO READ A SUBINDEX AT THE
           TIME OF A CALL TO OPEN AN END-OF-FILE WAS ENCOUNTERED OR WRONG NUMBER
           OF WORDS READ.

          The file has never been written and IO6600 failed to detect it;
          possible I/O error.

1163  ***  SYSTEM FATAL MESSAGE 1163, A READ ATTEMPT WHEN THE CORRESPONDING
           SUBINDEX IS ZERO.

          Normally this indicates an attempt to read past the
          end-of-information. However, if called from FILPOS, suspect is
          subroutine error in saving and returning a correct file position.

1164  ***  SYSTEM FATAL MESSAGE 1164, FOLLOWING A READ ATTEMPT ON AN INDEXED
           FILE, EITHER AN END-OF-FILE WAS ENCOUNTERED OR THE NUMBER OF WORDS
           READ WAS INCORRECT.

          I/O error.

1165  ***  SYSTEM FATAL MESSAGE 1165, ON AN ATTEMPT TO READ A SEQUENTIAL FILE,
           AN END-OF-FILE OR AN END-OF-INFORMATION WAS ENCOUNTERED.

1166  ***  SYSTEM FATAL MESSAGE 1166, ON AN ATTEMPT TO READ A SEQUENTIAL FILE, A
           LONG RECORD WAS ENCOUNTERED.

1167  ***  SYSTEM FATAL MESSAGE 1167, ON AN ATTEMPT TO READ A SEQUENTIAL FILE,
           A SHORT RECORD WAS ENCOUNTERED.

1168  ***  SYSTEM FATAL MESSAGE 1168, A CALL TO IO6600 WITH OPCODE=5 (FORWARD
           SPACE) IS NOT SUPPORTED.

1169  ***  SYSTEM FATAL MESSAGE 1169, ILLEGAL CALL TYPE, LOGIC ERROR IN IO6600.

1170  ***  SYSTEM FATAL MESSAGE 1170, ILLEGAL CALL TO NASTIO, LOGIC ERROR IN
           IO6600.

1171  ***  SYSTEM FATAL MESSAGE 1171, ON A POSITION CALL, THE BLOCK NUMBER
           REQUESTED IS NOT FOUND IN CORE WHEN IT IS EXPECTED THERE.

          Either the caller has written in the area furnished to NASTIO or
          there is a logic error in NASTIO.

1172  ***  SYSTEM FATAL MESSAGE 1172, WHEN ATTEMPTING TO READ A NEW INDEX, THE
           NUMBER OF WORDS RETURNED WAS INCORRECT.

          Either an I/O error or logic error in NASTIO.

1201  ***  SYSTEM FATAL MESSAGE 1201, FIAT OVERFLOW.

          FIAT /XFIAT/ overflowed; reduce number of logical files. See
          Section 2.4 of the Programmer's Manual.

1202  ***  SYSTEM FATAL MESSAGE 1202, DPL OVERFLOW.

          Data Pool Dictionary /XDPL/ overflowed; increase compiled size. See
          Section 2.4 of the Programmer's Manual.

1300  ***  SYSTEM FATAL MESSAGE 1300, END-OF-FILE WAS CALLED ON A FILE OPEN FOR
           INPUT.

1301  ***  SYSTEM FATAL MESSAGE 1301, END-OF-FILE ENCOUNTERED.

          An error In the calling program caused an unexpected end-of-file.

1302  ***  SYSTEM FATAL MESSAGE 1302, ZERO LENGTH RECORD SEGMENT ENCOUNTERED.

          A zero length record segment occurred before the last record in a
          block.

1303  ***  SYSTEM FATAL MESSAGE 1303, ATTEMPT TO GET A STRING PRIOR TO
           INFORMATION.

          There is an error in the calling program.

1304  ***  SYSTEM FATAL MESSAGE 1304, UNRECOGNIZED CONTROL WORD.

          The calling program may have overwritten a buffer.

1305  ***  SYSTEM FATAL MESSAGE 1305, BLOCK NUMBER CHECK FAILED.

          In the process of making a data block core resident, the block
          number did not have the expected value.

1306  ***  SYSTEM FATAL MESSAGE 1306, BLOCK NUMBER IN BLOCK TO BE WRITTEN DOES
           NOT MATCH NUMBER IN FILE CONTROL BLOCK.

1307  ***  SYSTEM FATAL MESSAGE 1307, BLOCK NUMBER OF BLOCK TO BE WRITTEN IS NOT
           IN CURRENT UNIT.

          The block number was not in the current unit and not equal to the
          block number in the preceding unit.

1308  ***  SYSTEM FATAL MESSAGE 1308, ATTEMPT TO READ BEYOND DATA.

1309  ***  SYSTEM FATAL MESSAGE 1309, CORE RESIDENT DATA BLOCK NUMBER DOES NOT
           MATCH NUMBER IN FILE CONTROL BLOCK.

1310  ***  SYSTEM FATAL MESSAGE 1310, POINTER TO NEXT CORE RESIDENT DATA BLOCK
           IS ZERO.

          Next block should be in core.

1311  ***  SYSTEM FATAL MESSAGE 1311, BLOCK NUMBER TO BE READ IS NOT INCLUDED IN
           CURRENT CHAIN OF UNITS.

1312  ***  SYSTEM FATAL MESSAGE 1312, BLOCK NUMBER OF BLOCK READ FROM DISK DOES
           NOT MATCH NUMBER IN FILE CONTROL BLOCK.

1313  ***  SYSTEM FATAL MESSAGE 1313, POINTER TO CORE RESIDENT DATA BLOCK IS
           POSITIONED PRIOR TO INFORMATION.

1314  ***  SYSTEM FATAL MESSAGE 1314, ATTEMPT TO POSITION A FILE OPENED TO
           WRITE.

1315  ***  SYSTEM FATAL MESSAGE 1315, BLOCK NUMBER NOT FOUND.

          Logic error in an attempt to position a core resident data block.

1316  ***  SYSTEM FATAL MESSAGE 1316, NO DATA EVENT CONTROL BLOCK AVAILABLE.

1317  ***  SYSTEM FATAL MESSAGE 1317, ERROR IN INTERNAL SUBROUTINE IN NASTIO.

1318  ***  SYSTEM FATAL MESSAGE 1318, ATTEMPT TO READ BEYOND END-OF-DATA.

1319  ***  SYSTEM FATAL MESSAGE 1319, DCB SYNCHRONOUS ERROR DETECTED.

          Data control block improperly written.

1320  ***  SYSTEM FATAL MESSAGE 1320, FIRST TERM IN ROW IS NOT A DIAGONAL TERM.

1321  ***  SYSTEM FATAL MESSAGE 1321, FIRST TERM IN ROW IS NOT A DIAGONAL TERM.

1322  ***  SYSTEM FATAL MESSAGE 1322, BAD STATUS RETURN ON A NTRAN READ CALL.

          Possible I/O error.

1323  ***  SYSTEM FATAL MESSAGE 1323, END-OF-DATA ENCOUNTERED.

          The unit on which the end-of-data occurred is not a tape.

1324  ***  SYSTEM FATAL MESSAGE 1324, INCORRECT WORD COUNT ON A NTRAN READ CALL.

          Number of words read by NTRAN is incorrect.

1325  ***  SYSTEM FATAL MESSAGE 1325, BAD STATUS RETURN ON A NTRAN WRITE CALL.

          Possible I/O error.

1326  ***  SYSTEM FATAL MESSAGE 1326, INCORRECT NUMBER OF WORDS PASSED BY NTRAN.

1327  ***  SYSTEM FATAL MESSAGE 1327, ILLEGAL RETURN FROM FWDREC.

1701  ***  SYSTEM WARNING MESSAGE 1701, AVAILABLE CORE EXCEEDED BY ******** LINE
           IMAGE BLOCKS.

1702  ***  SYSTEM INFORMATION MESSAGE 1702, UTILITY MODULE SEEMAT WILL ABANDON
           PROCESSING DATA BLOCK ********.

1704  ***  USER WARNING MESSAGE 1704, PLOT FILE - **** NOT SET UP.

1705  ***  SYSTEM WARNING MESSAGE 1705, LOGIC ERROR AT STATEMENT ***** IN
           SUBROUTINE SEEMAT.

1706  ***  USER WARNING MESSAGE 1706, PRECEDING BULK DATA DECK HAS BEEN CANCELED
           AND WILL NOT APPEAR ON USER MASTER FILE.

          The preceding Bulk Data Deck contains errors which preclude its
          inclusion on the User's Master File. Appropriate error message
          should appear in the echo of the Bulk Data Deck. Any subsequent
          Bulk Data Decks will be placed on the User's Master File if error-
          free. 

1707  ***  USER FATAL MESSAGE 1707, ILLEGAL TID VALUE ON UMF CARD.

          The TID value used on all UMF cards must be the same for any run
          and must match the TID value on the UMF tape being input. See
          Section 2.5 for details.

1708  ***  SYSTEM FATAL MESSAGE 1708, UMFEDT - UNEXPECTED EOF FROM READ.

          The occurrence of this message indicates a program failure in the
          User's Master File Editor subroutine UMFEDT.

1709  ***  SYSTEM FATAL MESSAGE 1709, UMFEDT - UNEXPECTED EOF FROM READ.

          The occurrence of this message indicates a program failure in the
          User's Master File Editor subroutine UMFEDT.

1710  ***  SYSTEM FATAL MESSAGE 1710, UMFEDT UNABLE TO OPEN ONE OF THE PERMANENT
           NASTRAN FILES UMF, NUMF, OR NPTP.

1711  ***  USER FATAL MESSAGE 1711, NO TAPE SETUP FOR EITHER UMF OR NUMF. THE
           USER MASTER FILE EDITOR REQUIRES AT LEAST ONE OF THESE TAPES TO BE
           SET UP.

          The tape(s) required must be appropriate to the requested action.
          See Section 2.5 for details.

1712  ***  USER WARNING MESSAGE 1712, REQUEST TO ADD DECK WITH PROBLEM
           IDENTIFICATION NO. = **** CONFLICTS WITH IMPLIED REQUEST TO COPY THE
           SAME PROBLEM FROM THE UMF. THE NEW DECK WILL BE USED.

          This message will occur whenever a deck is added whose PID value is
          the same as that of a problem already existing on the old User's
          Master File.

1713  ***  USER WARNING MESSAGE 1713, REMOVE REQUEST FOR PROBLEM **** IS OUT OF
           SEQUENCE OR NOT ON UMF.

          User's Master File Editor control cards must form an increasing
          sequence. See Section 2.5 for details.

1714  ***  USER WARNING MESSAGE 1714, LIST REQUEST FOR PROBLEM **** IS OUT OF
           SEQUENCE OR NOT ON UMF.

          User's Master File Editor control cards must form an increasing
          sequence. See Section 2.5 for details.

1715  ***  USER WARNING MESSAGE 1715, PUNCH REQUEST FOR PROBLEM **** IS OUT OF
           SEQUENCE OR NOT ON UMF.

          User's Master File Editor control cards must form an increasing
          sequence. See Section 2.5 for details.

1716  ***  USER FATAL MESSAGE 1716, PROBLEM WITH PID = **** IS NOT ON UMF OR
           CARD IS OUT OF SEQUENCE.

          User's Master File Editor control cards must form an increasing
          sequence. See Section 2.5 for details.

1717  ***  USER FATAL MESSAGE 1717, NUMF TAPE ID HAS ALREADY BEEN SPECIFIED.

          The tape id value for the New User's Master File (NUMF) may only be
          specified once. See Section 2.5 for details.

1718  ***  USER FATAL MESSAGE 1718, NUMF TAPE ID MAY NOT BE RESPECIFIED.

          The tape id value for the New User's Master File (NUMF) may only be
          specified once. See Section 2.5 for details.

1719  ***  USER WARNING MESSAGE 1719, PUNPRT REQUEST FOR PROBLEM **** IS OUT OF
           SEQUENCE OR NOT ON UMF.

          User's Master File Editor control cards must form an increasing
          sequence. See Section 2.5 for details.

1720  ***  SYSTEM FATAL MESSAGE 1720, UMFEDT UNABLE TO LOCATE BULK DATA ON NPTP.

1721  ***  USER FATAL MESSAGE 1721, BAD USER MASTER FILE EDITOR DATA CARD.

          See Section 2.5 for instructions for using the User's Master File
          Editor.

1722  ***  USER WARNING MESSAGE 1722, MISSING FINIS CARD. PROCESSING CONTINUING.

1723  ***  Reserved for future implementation in the User's Master File
Editor.

1724  ***  Reserved for future implementation in the User's Master File
Editor.

1725  ***  Reserved for future implementation in the User's Master File
Editor.

1726  ***  Reserved for future implementation in the Preface.

1727  ***  Reserved for future implementation in the Preface.

1728  ***  Reserved for future implementation in the Preface.

1729  ***  Reserved for future implementation in the Preface.

1730  ***  Reserved for future implementation in the Preface.

1731  ***  Reserved for future implementation in the Preface.

1732  ***  Reserved for future implementation in the Preface.

1733  ***  Reserved for future implementation in the Preface.

1734  ***  Reserved for future implementation in the Preface.

3735  ***  Reserved for future implementation in the Preface.

1736  ***  Reserved for future implementation in the Preface.

1737  ***  Reserved for future implementation in the Preface.

1738  ***  USER FATAL MESSAGE 1738, UTILITY MODULE INPUT FIRST PARAMETER VALUE
           *** OUT OF RANGE.

          In the test problem generating version of utility module INPUT, the
          first parameter value specifies the specific problem type as
          follows:

          1. Laplace circuit (an N x N array of scalar points connected by
          scalar springs and optionally by scalar masses).
          2. Rectangular frame made from BARS or RODS.
          3. Rectangular plate made from QUAD1 elements.
          4. Rectangular plate made from TRIA1 elements.
          5. N-segment string modeled with scalar elements.
          6. N-cell beam made from BAR elements.
          7. N-order full matrix generator with optional load.
          8. N-spoke wheel.

1739  ***  SYSTEM FATAL MESSAGE 1739, UNABLE TO OPEN FILE

          This message can occur if a required output file is purged in
          utility module INPUT.

1740  ***  SYSTEM FATAL MESSAGE 1740, EOF ENCOUNTERED.

          An unexpected end-of-file has been encountered while reading an
          input data block in utility module INPUT.

1741  ***  SYSTEM FATAL MESSAGE 1741, EOR ENCOUNTERED.

          An unexpected end-of-record indicator has been encountered while
          reading an input data block in utility module INPUT.

1742  ***  SYSTEM FATAL MESSAGE 1742, NO DATA PRESENT.

          Utility module INPUT; input data block contains no data records.

1743  ***  SYSTEM FATAL MESSAGE 1743, EOF FROM FWDREC.

          Utility module INPUT encountered an end-of-file on an input data
          block while attempting to read past the header record.

1744  ***  USER FATAL MESSAGE 1744, DATA CARD(S) ******** GENERATED BY UTILITY
           MODULE INPUT NOT ALLOWED IN BULK DATA.

          Module is not capable of integrating same card type from two
          sources.

1745  ***  *************************

          Message 1745 is reserved for utility module INPUT.

=PAGE=
6.4  FUNCTIONAL MODULE MESSAGES (2001 THROUGH 3000)

2001  ***  USER FATAL MESSAGE 2001, SEQGP CARD REFERENCES UNDEFINED GRID POINT
           ****.

2002  ***  SYSTEM FATAL MESSAGE 2002, GRID POINT **** NOT IN EQEXIN.

          This message indicates a program design error in GP1.

2003  ***  USER FATAL MESSAGE 2003, COORDINATE SYSTEM **** REFERENCES UNDEFINED
           GRID POINT ****.

          Applies to CORD1j definitions.

2004  ***  USER FATAL MESSAGE 2004, COORDINATE SYSTEM **** REFERENCES UNDEFINED
           COORDINATE SYSTEM ****.

          Applies to CORD2j definitions.

2005  ***  SYSTEM FATAL MESSAGE 2005, INCONSISTENT COORDINATE SYSTEM DEFINITION.

          At least one coordinate system is so defined that it cannot be
          related to the basic coordinate system. See Section 4.21.7.4 of the
          Programmer's Manual.

2006  ***  USER FATAL MESSAGE 2006, INTERNAL GRID POINT **** REFERENCES
           UNDEFINED COORDINATE SYSTEM

          The grid point whose internal sequence number is printed above
          references an undefined coordinate system in either field 3 or
          field 7 of a GRID card.

2007  ***  USER FATAL MESSAGE 2007, ELEMENT **** REFERENCES UNDEFINED GRID POINT
           ****.

2008  ***  USER FATAL MESSAGE 2008, LOAD SET **** REFERENCES UNDEFINED GRID
           POINT ****.

2009  ***  USER FATAL MESSAGE 2009, TEMP SET **** REFERENCES UNDEFINED GRID
           POINT ****.

2010  ***  USER FATAL MESSAGE 2010, ELEMENT **** REFERENCES UNDEFINED GRID POINT
           ****.

2011  ***  USER FATAL MESSAGE 2011, NO PROPERTY CARD FOR ELEMENT TYPE ****.

2012  ***  USER FATAL MESSAGE 2012, GRID POINT **** SAME AS SCALAR POINT.

          Identification numbers of grid and scalar points must be unique.

2013  ***  USER WARNING MESSAGE 2013, NO STRUCTURAL ELEMENTS EXIST.

          Model checked for structural elements.

2014  ***  SYSTEM FATAL MESSAGE 2014, LOGIC ERROR IN ECPT CONSTRUCTION.

          The spill logic in the construction of the skeleton (TA1B) has
          failed. Problem should be referred to maintenance programming
          staff. A temporary fix may be available if additional storage can
          be provided to NASTRAN, for example, by increasing the region size
          (IBM 360).

2015  ***  USER WARNING MESSAGE 2015, EITHER NO ELEMENTS CONNECT INTERNAL GRID
           POINT ******** OR IT IS CONNECTED TO A RIGID ELEMENT OR A GENERAL
           ELEMENT.

          The message is a warning only since the degrees of freedom
          associated with the point may be removed by multipoint constraints
          or in other ways. The internal identification number is formed by
          assigning to each grid point and scalar point one of the integers
          1, 2, --- according to its resequenced position. It may be
          determined from data block EQEXIN via a DMAP TABPT instruction.

2016  ***  USER INFORMATION MESSAGE 2016, GIVENS TIME ESTIMATE IS ********
(1)        SECONDS. PROBLEM SIZE IS ********, SPILL WILL OCCUR FOR THIS CORE AT
           A PROBLEM SIZE OF ********.

2016  ***  USER FATAL MESSAGE 2016, NO MATERIAL PROPERTIES EXIST.
(2)

2017  ***  USER FATAL MESSAGE 2017, MATS1 CARD REFERENCES UNDEFINED MAT1 ****
           CARD.

          Check that all MATS1 cards reference MAT1 cards that exist in the
          Bulk Data Deck.

2018  ***  USER FATAL MESSAGE 2018, MATS2 CARD REFERENCES UNDEFINED MAT2 ****
           CARD.

          Check that all MATS2 cards reference MAT2 cards that exist in the
          Bulk Data Deck.

2019  ***  USER FATAL MESSAGE 2019, MATT1 CARD REFERENCES UNDEFINED MAT1 ****
           CARD.

          Check that all MATT1 cards reference MAT1 cards that exist in the
          Bulk Data Deck.

2020  ***  USER FATAL MESSAGE 2020, MATT2 CARD REFERENCES UNDEFINED MAT2 ****
           CARD.

          Check that all MATT2 cards reference MAT2 cards that exist in the
          Bulk Data Deck.

2021  ***  SYSTEM FATAL MESSAGE 2021, BAD GMMAT CALLING SEQUENCE.

          The calling sequence of the subroutine which called either
          subroutine GMMATD or GMMATS defined a nonconformable matrix
          product. GMMATD and GMMATS examine the transpose flags in
          combination with the orders of the matrices to make sure that a
          conformable matrix product is defined by the input data. This test
          clearly is made for purposes of calling routine checkout only. No
          tests are made, nor can they be made, to ensure that the calling
          routine has provided sufficient storage for arrays.

2022  ***  SYSTEM FATAL MESSAGE 2022, SMA-B SCALAR POINT INSERTION LOGIC ERROR.

          Probable error in creating the ECPT data block in module TA1. Use
          the TABPT module to print ECPT.

2023  ***  SYSTEM FATAL MESSAGE 2023, DETCK UNABLE TO FIND PIVOT POINT **** IN
           GPCT.

          Probable error in creating the ECPT data block in module TA1. Use
          the TABPT module to print ECPT.

2024  ***  USER FATAL MESSAGE 2024, OPERATION CODE ******** NOT DEFINED FOR
           MODULE PARAM.

          The use of V,N,SUB rather than C,N,SUB can cause this.

2025  ***  USER FATAL MESSAGE 2025, UNDEFINED COORDINATE SYSTEM

          The coordinate system identification number transmitted via ECPT(1)
          could not be found in the CSTM array. Check coordinate system
          numbers used on bulk data cards against those defined on CORD1C,
          CORD1R, etc., bulk data cards to insure that there are no undefined
          coordinate systems.

2026  ***  USER FATAL MESSAGE 2026, ELEMENT **** GEOMETRY YIELDS UNREASONABLE
           MATRIX.

          Referenced element geometry and/or properties yields a numerical
          result which causes an element stiffness or mass matrix to be
          undefined. Possible causes include, but are not limited to, (1) the
          length of a rod or bar is zero because the end points have the same
          coordinates, (2) the sides of a triangle or quadrilateral are
          collinear which leads to a zero cross product in defining an
          element coordinate system, or (3) the bar orientation vector is
          parallel to the bar axis. Check GRID bulk data cards defining
          element end points for bad data.

2027  ***  USER FATAL MESSAGE 2027, ELEMENT **** HAS INTERIOR ANGLE GREATER THAN
           180 DEG. AT GRID POINT ****.

          SHEAR or TWIST panel element with the referenced element number has
          been defined with the four grid points out of the proper cyclical
          order. See bulk data card definitions for CSHEAR and CTWIST cards.

2028  ***  SYSTEM FATAL MESSAGE 2028, SMA3A ERROR NO. ****.

          Internal logic error in subroutine SMA3A of module SMA3. Possible
          error in generation of the GEI data block. Use the TABPT module to
          print GEI.

2029  ***  USER FATAL MESSAGE 2029, UNDEFINED TEMPERATURE SET ****.

          The referenced temperature set had no default temperature defined.
          Define a temperature or default temperature for each grid point in
          the model.

2030  ***  SYSTEM FATAL MESSAGE 2030, BAD GPTT.

          The format of the GPTT data block is incorrect. Use the TABPT
          module to print the GPTT data block.

2031  ***  USER FATAL MESSAGE 2031, ELEMENT **** UNACCEPTABLE GEOMETRY.

2032  ***  USER FATAL MESSAGE 2032, ELEMENT **** UNACCEPTABLE GEOMETRY.

2033  ***  USER FATAL MESSAGE 2033, SINGULAR H-MATRIX FOR ELEMENT ****.

2034  ***  SYSTEM FATAL MESSAGE 2034, ELEMENT **** SIL'S DO NOT MATCH PIVOT.

          Possible error in generation of the ECPT data block. Use the TABPT
          module to print ECPT.

2035  ***  USER FATAL MESSAGE 2035, QUADRILATERAL **** INTERIOR ANGLE GREATER
           THAN 180 DEG.

2036  ***  USER FATAL MESSAGE 2036, SINGULAR MATRIX FOR ELEMENT ****.

2037  ***  USER FATAL MESSAGE 2037, BAD ELEMENT **** GEOMETRY.

2038  ***  SYSTEM FATAL MESSAGE 2038, SINGULAR MATRIX FOR ELEMENT ****.

2039  ***  USER FATAL MESSAGE 2039, ZERO SLANT LENGTH FOR HARMONIC **** OF
           CCONEAX ****.

2040  ***  USER FATAL MESSAGE 2040, SINGULAR MATRIX FOR ELEMENT ****.

2041  ***  USER FATAL MESSAGE 2041, A MATT1,MATT2,MATT3 OR MATS1 CARD REFERENCES
           TABLE NUMBER **** WHICH IS NOT DEFINED ON A TABLEM1, TABLEM2,
           TABLEM3, TABLEM4 OR TABLES1 CARD.

          Ensure that all table identification numbers on MATT1, MATT2,
          MATT3, or MATS1 cards reference tables which exist in the Bulk Data
          Deck.

2042  ***  USER FATAL MESSAGE 2042, MISSING MATERIAL TABLE **** FOR ELEMENT
           ****.

          The referenced material table identification number is missing.
          Check to see that all element property bulk data cards (for
          example, PBAR, PROD) reference material card identification numbers
          for material property cards that exist in the Bulk Data Deck.

2043  ***  USER WARNING MESSAGE 2043, OFP HAS INSUFFICIENT CORE FOR ONE GINO
(1)        BUFFER **** OFP NOT EXECUTED.

2043  ***  USER FATAL MESSAGE 2043, MISSING MATERIAL TABLE ********.
(2)

2044  ***  USER FATAL MESSAGE 2044, UNDEFINED TEMPERATURE SET ****.

          The referenced temperature set was selected in the Case Control
          Deck but not defined in the Bulk Data Deck.

2045  ***  USER FATAL MESSAGE 2045, TEMPERATURE UNDEFINED AT GRID POINT WITH
           INTERNAL INDEX ****.

          Temperatures must be defined at all grid points in a selected
          temperature set. The grid point whose internal index was printed
          had no temperature defined and a default temperature was not
          supplied for the selected temperature set.

2046  ***  USER FATAL MESSAGE 2046, UNDEFINED ELEMENT DEFORMATION SET ****.

2047  ***  USER FATAL MESSAGE 2047, UNDEFINED MULTIPOINT CONSTRAINT SET ****.

          An MPC set selected in the Case Control Deck could not be found on
          either an MPC or MPCADD card or a set referenced on a MPCADD card
          could not be found on an MPC card.

2048  ***  USER FATAL MESSAGE 2048, UNDEFINED GRID POINT **** IN MULTI-POINT
           CONSTRAINT SET ****.

2049  ***  USER FATAL MESSAGE 2049, UNDEFINED GRID POINT **** HAS AN OMITTED
           COORDINATE.

          An OMIT or OMIT1 card references a grid point which has not been
          defined.

2050  ***  USER FATAL MESSAGE 2050, UNDEFINED GRID POINT **** HAS A SUPPORT
           COORDINATE.

          A SUPORT card references a grid point which has not been defined.

2051  ***  USER FATAL MESSAGE 2051, UNDEFINED GRID POINT **** IN SINGLE-POINT
           CONSTRAINT SET ****.

          An SPC1 card in the selected SPC set references a grid point which
          has not been defined.

2052  ***  USER FATAL MESSAGE 2052, UNDEFINED GRID POINT **** IN SINGLE-POINT
           CONSTRAINT SET ****.

          An SPC card in the selected SPC set references a grid point which
          has not been defined.

2053  ***  USER FATAL MESSAGE 2053, UNDEFINED SINGLE-POINT CONSTRAINT SET ****.

          An SPC set selected in the Case Control Deck could not be found on
          either an SPCADD, SPC, or SPC1 card, or a set referenced on an
          SPCADD card could not be found on either an SPC or SPC1 card.

2054  ***  USER FATAL MESSAGE 2054, SUPER ELEMENT **** REFERENCES UNDEFINED
           SIMPLE ELEMENT ****.

2055  ***  SYSTEM WARNING MESSAGE 2055.

2056  ***  USER FATAL MESSAGE 2056, UNDEFINED SUPER ELEMENT **** PROPERTIES.

2057  ***  USER FATAL MESSAGE 2057, IRRATIONAL SUPER ELEMENT **** TOPOLOGY.

2058  ***  USER WARNING MESSAGE 2058, ELEMENT ******** CONTRIBUTES TO THE
           DAMPING MATRIX WHICH IS PURGED. IT WILL BE IGNORED.

2059  ***  USER FATAL MESSAGE 2059, UNDEFINED GRID POINT **** ON  SE--BFE FOR
           SUPER ELEMENT ****.

2060  ***  USER FATAL MESSAGE 2060, UNDEFINED GRID POINT **** ON QDSEP CARD FOR
           SUPER ELEMENT ****.

2061  ***  USER FATAL MESSAGE 2061, UNDEFINED GRID POINT **** ON GENERAL ELEMENT
           ****.

2062  ***  USER FATAL MESSAGE 2062, UNDEFINED SUPER ELEMENT PROPERTY **** FOR
           SUPER ELEMENT ****.

2063  ***  SYSTEM FATAL MESSAGE 2063, TA1C LOGIC ERROR. GENERAL ELEMENT DATA
           COULD NOT BE FOUND IN THE ECT DATA BLOCK WHEN TRAILER LIST INDICATED
           IT WAS PRESENT. REFER PROBLEM TO MAINTENANCE PROGRAMMING STAFF.

2064  ***  USER FATAL MESSAGE 2064, UNDEFINED EXTRA POINT **** REFERENCED ON
           SEQEP CARD.

2065  ***  USER FATAL MESSAGE 2065, UNDEFINED GRID POINT **** ON DMIG CARD.

2066  ***  USER FATAL MESSAGE 2066, UNDEFINED GRID POINT **** ON RLOAD- OR
           TLOAD- CARD.

2067  ***  USER FATAL MESSAGE 2067, UNDEFINED GRID POINT ******** IN NONLINEAR
           (NOLINi) LOAD SET ********.

2068  ***  USER FATAL MESSAGE 2068, UNDEFINED GRID POINT **** IN TRANSFER
           FUNCTION SET ****.

2069  ***  USER FATAL MESSAGE 2069, UNDEFINED GRID POINT **** IN TRANSIENT
           INITIAL CONDITION SET ****.

2070  ***  USER FATAL MESSAGE 2070, REQUESTED DMIG MATRIX **** IS UNDEFINED.

2071  ***  USER FATAL MESSAGE 2071, DYNAMIC LOAD SET ******** REFERENCES
           UNDEFINED ******** SET ********.

          This message is issued when DAREA, DELAY, or DPHASE set IDs are
          referenced on a TLOADi or RLOADi card but are not defined.

2072  ***  SYSTEM WARNING MESSAGE 2072, CARD TYPE *** NOT FOUND ON DATA BLOCK.

          This warning message is issued when the trailer bit for the card
          type is set to 1 but the corresponding record is not on the data
          block.

2074  ***  USER FATAL MESSAGE 2074, UNDEFINED TRANSFER FUNCTION SET ****.

2075  ***  USER FATAL MESSAGE 2075, IMPROPER KEYWORD ******** FOR APPROACH
           PARAMETER IN DMAP INSTRUCTION.

2076  ***  USER WARNING MESSAGE 2076, SDR2 OUTPUT DATA BLOCK NO. 1 IS PURGED.

2077  ***  USER WARNING MESSAGE 2077, SDR2 OUTPUT DATA BLOCK NO. 2 IS PURGED.

2078  ***  USER WARNING MESSAGE 2078, SDR2 OUTPUT DATA BLOCK NO. 3 IS PURGED.

2079  ***  USER WARNING MESSAGE 2079, SDR2 FINDS THE -EDT-, -EST-, OR -GPTT-
           PURGED OR INADEQUATE AND IS THUS NOT PROCESSING ANY REQUESTS FOR
           STRESSES OR FORCES.

2080  ***  USER WARNING MESSAGE 2080, SDR2 OUTPUT DATA BLOCK NO. 6 IS PURGED.

2081  ***  USER FATAL MESSAGE 2081, DIFFERENTIAL STIFFNESS CAPABILITY NOT
           DEFINED FOR ANY OF THE ELEMENT TYPES IN THE PROBLEM.

          Differential stiffness is not defined for all structural elements.
          Only the following elements are defined for differential stiffness
          calculations: ROD, TUBE, SHEAR (but not TWIST) panels, triangular
          and quadrilateral membranes (TRMEM, TRIA2, QDMEM, QUAD2), and BAR.
          The combination two-dimensional elements, TRIA1 and QUAD1, are
          defined only if their membrane thickness is nonzero. You have not
          included any of these elements in his model and therefore a null
          differential stiffness matrix was generated.

2083  ***  USER FATAL MESSAGE 2083, NULL DISPLACEMENT VECTOR.

          The displacement vector for the linear solution part of a static
          analysis with differential stiffness problem, or the incremental
          displacement vector in a piecewise linear analysis rigid format
          problem, is the zero vector. Check loading conditions.

2084  ***  SYSTEM FATAL MESSAGE 2084, DSMG2 LOGIC ERROR ****.

          Incompatible input and output pairs in the DMAP calling sequence to
          module DSMG2. See the module description for DSMG2 in the
          Programmer's Manual.

2085  ***  USER INFORMATION MESSAGE 2085, **** SPILL, NPVT ****.

          During processing of the ECPT data block in module ****, so many
          elements were attached to the referenced pivot point (NPVT) that
          module spill logic was initiated.

2086  ***  USER INFORMATION 2086, SMA2 SPILL, NPVT ****.

          See explanation for Message 2085.

2087  ***  SYSTEM FATAL MESSAGE 2087, ECPT CONTAINS BAD DATA.

          Use the TABPT module to print the ECPT data block.

2088  ***  USER FATAL MESSAGE 2088, DUPLICATE TABLE ID ****.

          All tables must have unique numbers. Check for uniqueness.

2089  ***  USER FATAL MESSAGE 2089, TABLE **** UNDEFINED.

          The table number in the list of table numbers input to subroutine
          PRETAB via argument 7 was not found after reading the DIT data
          block. Check list of tables in the Bulk Data Deck.

2090  ***  SYSTEM FATAL MESSAGE 2090, TABLE DICTIONARY ENTRY **** MISSING.

          Logic error in subroutine PRETAB, or open core used by PRETAB has
          been destroyed.

2091  ***  SYSTEM FATAL MESSAGE 2091, PLA3, BAD ESTNL EL ID ****.

          ESTNL data block is not in expected format. Use TABPT module to
          print the ESTNL data block.

2092  ***  SYSTEM WARNING MESSAGE 2092, SDR2 FINDS A SYMMETRY SEQUENCE LENGTH =
           **** AND AN INSUFFICIENT NUMBER OF VECTORS AVAILABLE = **** WHILE
           ATTEMPTING TO COMPUTE STRESSES AND FORCES. ALL FURTHER STRESS AND
           FORCE COMPUTATION TERMINATED.

2093  ***  USER FATAL MESSAGE 2093, NOLIN CARD FROM NOLIN SET **** REFERENCES
           GRID POINT **** UD SET.

2094  ***  USER WARNING MESSAGE 2094, SUBROUTINE TABFMT, KEYNAME ******** NOT IN
           LIST OF AVAILABLE KEYNAMES. *** LIST OF RECOGNIZED KEYNAMES FOLLOWS.

          The TABPRT module can only be used to print certain table data
          blocks. For table data blocks not appearing in the list, use the
          TABPT Module.

2095  ***  USER WARNING MESSAGE 2095, SUBROUTINE TABFMT, PURGED INPUT.

2096  ***  USER WARNING MESSAGE 2096, SUBROUTINE TABFMT, EOF ENCOUNTERED.

2097  ***  USER WARNING MESSAGE 2097, SUBROUTINE TABFMT, EOR ENCOUNTERED.

2098  ***  USER WARNING MESSAGE 2098, SUBROUTINE TABFMT, INSUFFICIENT CORE.

2099  ***  USER WARNING MESSAGE 2099, SUBROUTINE TABFMT, KF ********.

2100  ***  USER FATAL MESSAGE 2100, TEMPERATURE SPECIFIED AS ******** AND
           ******** FOR GRID ********.

          Conflicting data has been supplied to specify the temperatures at a
          grid point.

2101A ***  USER FATAL MESSAGE 2101A, GRID POINT **** COMPONENT *** ILLEGALLY
           DEFINED IN SETS ****.

          The above grid point and component has been defined in each of the
          above dependent subsets. A point may belong to at most one
          dependent subset.

2101B ***  USER FATAL MESSAGE 21O1B, SCALAR POINT **** ILLEGALLY DEFINED IN SETS
           ****.

2102  ***  USER WARNING MESSAGE 2102, LEFT-HAND MATRIX ROW POSITION **** OUT OF
           RANGE - IGNORED.

          A term in the A matrix whose row position is larger than the stated
          dimension was detected and ignored.

2103  ***  SYSTEM FATAL MESSAGE 2103, SUBROUTINE MAT WAS CALLED WITH INFLAG=2,
           THE SINE OF ANGLE X, MATERIAL ORIENTATION ANGLE, NONZERO, BUT
           SIN(X)**2+COS(X)**2 DIFFERED FROM 1 IN ABSOLUTE VALUE BY MORE THAN
           .0001.

          A check is made in MAT to insure that ABS ( SIN ( THETA ) **2 + COS
          ( THETA ) **2 - 1.0O ) .LE. .0001 when INFLAG = 2. The calling
          routine did not set SINTH and COSTH cells in /MATIN/ properly.

2104  ***  USER FATAL MESSAGE 2104, UNDEFINED COORDINATE SYSTEM ****.

          See the explanation for Message 2025.

2105  ***  USER FATAL MESSAGE 2105, PLOAD2 CARD FROM LOAD SET **** REFERENCES
           MISSING OR NON-2-D ELEMENT ****.

          PLOAD2 cards must reference two-dimensional elements.

2106  ***  USER FATAL MESSAGE 2106, LOAD CARD DEFINES NONUNIQUE LOAD SET ****.

2107  ***  USER FATAL MESSAGE 2107, EIG- CARD FROM SET **** REFERENCES DEPENDENT
           COORDINATE OR GRID POINT ****.

          When the point option is used on an EIGB, EIGC, or EIGR card, the
          referenced point and component must be in the analysis set for use
          in normalization.

2109  ***  USER FATAL MESSAGE 2109, NO GRID, SCALAR OR EXTRA POINTS DEFINED.

2110  ***  USER WARNING MESSAGE 2110, INSUFFICIENT CORE TO HOLD CONTENTS OF GINO
           FILE *** FURTHER PROCESSING OF THIS DATA BLOCK IS ABANDONED.

2111  ***  USER WARNING MESSAGE 2111, BAR **** COUPLED BENDING INERTIA SET TO
           0.0 IN DIFFERENTIAL STIFFNESS.

          The coupled bending inertia term on a PBAR card, if nonzero, is set
          to zero in the differential stiffness routine for the BAR.

2112  ***  SYSTEM FATAL MESSAGE 2112, UNDEFINED TABLE ****.

          The referenced table number could not be found in core.

2113  ***  USER FATAL MESSAGE 2113, MATERIAL ****, A NON-MAT1 TYPE, IS NOT
           ALLOWED TO BE STRESS-DEPENDENT.

          Only MAT1 material cards may be present in a piecewise linear
          analysis problem.

2114  ***  USER FATAL MESSAGE 2114, MATT3 CARD REFERENCES UNDEFINED MAT3 ****
           CARD.

          Check that all MATT3 cards reference MAT3 cards that exist in the
          Bulk Data Deck. This can also happen if ID noted by **** could not
          be found on MAT1 card (see Message 2042).

2115  ***  USER FATAL MESSAGE 2115, TABLE **** (TYPE ****) ILLEGAL WITH STRESS-
           DEPENDENT MATERIAL.

          Only TABLES1 cards may be used to define stress-strain curves for
          use in piecewise linear analysis.

2116  ***  SYSTEM FATAL MESSAGE 2116, MATID **** TABLEID ****.

          The referenced material table identification number could not be
          found among the set of all MAT1 cards in core.

2117  ***  USER FATAL MESSAGE 2117, TEMPERATURE DEPENDENT MATERIAL PROPERTIES
           ARE NOT PERMISSIBLE IN A PIECEWISE LINEAR ANALYSIS PROBLEM.
           TEMPERATURE SET = ****.

          Redefine your problem without temperature dependent material
          properties.

2118  ***  USER INFORMATION MESSAGE 2118, SUBROUTINE GP4PRT, - DIAG 21 SET-DOF
           VS. DISP SETS FOLLOWS.

2119  ***  USER INFORMATION MESSAGE 2119, SUBROUTINE GP4PRT, - DIAG 22 SET-DISP
           SETS VS. DOF FOLLOWS.

2120  ***  USER FATAL MESSAGE 2120, MODULE VEC - BOTH SUBSET BITS ARE NON-ZERO.
           I = ********.

2121  ***  USER FATAL MESSAGE 2121, MODULE VEC - BOTH SUBSET BITS ARE ZERO. I =
           ********.

2122  ***  USER FATAL MESSAGE 2122, MODULE VEC - SET X BIT IS ZERO BUT SUBSET XO
           BIT IS NOT. I = ********.

2123  ***  USER FATAL MESSAGE 2123, MODULE VEC - SET X BIT IS ZERO BUT SUBSET X1
           BIT IS NOT. I= ********.

2124  ***  USER WARNING MESSAGE 2124, MODULE VEC - NR=0, OUTPUT WILL BE PURGED.

2125  ***  USER WARNING MESSAGE 2125, MODULE VEC - NZ=0, OUTPUT WILL BE PURGED.

2126  ***  USER FATAL MESSAGE 2126, UNDEFINED MATERIAL FOR ELEMENT ********.

2127  ***  SYSTEM FATAL MESSAGE 2127, PLA2 INPUT DATA BLOCK NO. **** IS PURGED.

          Data blocks DELTAUGV and DELTAPG cannot be purged. See module
          description for PLA2 in Section 4 of the Programmer's Manual.

2128  ***  SYSTEM FATAL MESSAGE 2128, PLA2 OUTPUT DATA BLOCK NO. **** IS PURGED.

          Data blocks UGV1 and PGV1 cannot be purged. See module description
          for PLA2 in Section 4 of the Programmer's Manual.

2129  ***  SYSTEM FATAL MESSAGE 2129, PLA2, ZERO VECTOR ON APPENDED DATA BLOCK
           NO. ****.

          Zero displacement vector found on UGV1 data block output from PLA2.
          Possible system failure.

2130  ***  USER FATAL MESSAGE 2130, ZERO INCREMENTAL DISPLACEMENT VECTOR NOT
           ADMISSIBLE AS INPUT TO MODULE PLA2.

          See discussion of the Piecewise Linear Analysis rigid format (DISP
          Rigid Format 6) in Volume II, Section 2.6.

2131  ***  USER FATAL MESSAGE  2131, NON-SCALAR ELEMENT *** REFERENCES A SCALAR
           POINT.

          An element which must be attached to a geometric grid point has
          been attached to a scalar point. No geometry data can be inferred.

2132  ***  USER FATAL MESSAGE 2132, NON-ZERO SINGLE POINT CONSTRAINT VALUE
           SPECIFIED BUT DATA BLOCK YS IS PURGED.

          Many rigid formats do not support constrained displacements
          (especially dynamic solutions). An attempt to specify a constrained
          displacement in these cases results in this message.

2133  ***  USER FATAL MESSAGE 2133, INITIAL CONDITION IN SET **** SPECIFIED FOR
           POINT NOT IN ANALYSIS SET.

          Initial conditions can only be specified for analysis set points.
          Therefore the point/component mentioned on TIC cards must belong to
          the D or H sets.

2134  ***  USER FATAL MESSAGE 2134, LOAD SET *** DEFINED FOR BOTH GRAVITY AND
           NON-GRAVITY LOADS.

          The same load set identification number cannot appear on both a
          GRAV card and another loading card such as FORCE or MOMENT. To
          apply both a gravity load and a concentrated load simultaneously,
          the LOAD card must be used in the Bulk Data Deck.

2135  ***  USER FATAL MESSAGE 2135, DLOAD CARD *** HAS A DUPLICATE SET ID FOR
           SET ID ***.

          The Li set IDs on a DLOAD card are not unique. See the DLOAD card
          description in Section 2.4.

2136  ***  USER FATAL MESSAGE 2136, SET ID *** HAS BEEN DUPLICATED ON A DLOAD,
           RLOAD1,2 OR TLOAD1,2 CARD.

          All dynamic load set IDs must be unique.

2137  ***  USER FATAL MESSAGE 2137, PROGRAM RESTRICTION FOR MODULE SSG1 - ONLY
           360 LOAD SET ID-S ALLOWED. DATA CONTAINS **** LOAD SET ID-S.

          Reduce the number of load set IDs.

2138  ***  USER FATAL MESSAGE 2138, ELEMENT IDENTIFICATION NUMBER **** IS TOO
           LARGE.

          Element identification numbers (on connection cards) must be less
          than 16,777,215.

2139  ***  USER FATAL MESSAGE 2139, ELEMENT **** IN DEFORM SET **** IS
           UNDEFINED.

          A selected element deformation set includes an element twice,
          includes a non-existent element, or includes a non-one-dimensional
          element.

2140  ***  USER FATAL MESSAGE 2140, GRID POINT OR SCALAR POINT ID *** IS TOO
           LARGE.

          Program restriction on the size of integer numbers. A card defining
          a grid point or scalar point has a number larger than 2,000,000.

2141  ***  USER FATAL MESSAGE 2141, MODULE VEC - EOF ENCOUNTERED WHILE READING
           GINO FILE **** DATA BLOCK ********.

2142  ***  USER FATAL MESSAGE 2142, INSUFFICIENT CORE FOR MODULE VEC. AVAILABLE
           CORE = ******** WORDS. ADDITIONAL CORE NEEDED = ******** WORDS.

2143  ***  USER FATAL MESSAGE 2143, MODULE VEC UNABLE TO IDENTIFY SET OR SUBSET
           DESCRIPTOR ********.

2145  ***  USER FATAL MESSAGE 2145, ******** FATAL MESSAGES HAVE BEEN GENERATED
           IN SUBROUTINE VEC. ONLY THE FIRST **** HAVE BEEN PRINTED.

2146  ***  USER FATAL MESSAGE 2146, BOTH OF THE SECOND AND THIRD VEC PARAMETERS
           REQUEST COMPLEMENT.

2147  ***  SYSTEM FATAL MESSAGE 2147, ILLEGAL ELEMENT TYPE = ********
           ENCOUNTERED BY DSMG1 MODULE.

2149  ***  SYSTEM FATAL MESSAGE 2149, SUBROUTINE ****. FIRST ELEMENT OF A COLUMN
           OF LOWER TRIANGULAR MATRIX IS NOT THE DIAGONAL ELEMENT.

2150  ***  USER FATAL MESSAGE 2150, ILLEGAL VALUE FOR FOURTH PARAMETER =
           ********.

2151  ***  USER WARNING MESSAGE 2151, -PLAARY- ARRAY IS SMALLER THAN MAXIMUM
           NUMBER OF ELEMENT TYPES.

2152  ***  USER FATAL MESSAGE 2152, GRID POINT ******** COMPONENT ** DUPLICATELY
           DEFINED IN THE **** SET.

2153  ***  USER FATAL MESSAGE 2153, SCALAR POINT ******** DUPLICATELY DEFINED IN
           THE **** SET.

2154  ***  USER WARNING MESSAGE 2154, ZERO AREA OR ILLEGAL CONNECTION FOR HBDY
           ELEMENT NUMBER ********.

2155  ***  USER WARNING MESSAGE 2155, MAT4 AND MAT5 MATERIAL DATA CARDS HAVE
           SAME ID = ************** MAT4 DATA WILL BE SUPPLIED WHEN CALLED FOR
           THIS ID.

2156  ***  SYSTEM FATAL MESSAGE 2156, ILLEGAL INFLAG = ************** RECEIVED
           BY HMAT.

2157  ***  USER FATAL MESSAGE 2157, MATERIAL ID = ************** DOES NOT APPEAR
           ON ANY MAT4 OR MAT5 MATERIAL DATA CARD.

2158  ***  SYSTEM WARNING MESSAGE 2158, A TRAPRG ELEMENT = ************** DOES
           NOT HAVE SIDE 1-2 PARALLEL TO SIDE 3-4.

2159  ***  USER FATAL MESSAGE 2159, TRIARG OR TRAPRG ELEMENT = **************
           POSSESSES ILLEGAL GEOMETRY.

2160  ***  USER FATAL MESSAGE 2160, BAD GEOMETRY ON ZERO COEFFICIENT FOR SLOT
           ELEMENT NUMBER **************.

2161  ***  SYSTEM WARNING MESSAGE 2161, PARTITION FILE, **** IS OF SIZE
           ********** ROWS BY ********** COLS. PARTITIONING VECTORS INDICATE
           THAT THIS PARTITION SHOULD BE OF SIZE ********** ROWS BY **********
           COLUMNS FOR A SUCCESSFUL MERGE.

2162  ***  SYSTEM WARNING MESSAGE 2162, THE FORM PARAMETER AS GIVEN TO THE MERGE
           MODULE IS INCONSISTENT WITH THE SIZE OF THE MERGED MATRIX, HOWEVER IT
           HAS BEEN USED. FORM = **********, SIZE = ********** ROWS BY
           ********** COLUMNS.

2163  ***  SYSTEM WARNING MESSAGE 2163, REQUESTED VALUE OF **** ******** ***
           USED BY ********. LOGICAL CHOICE IS ********.

2165  ***  USER FATAL MESSAGE 2165, ILLEGAL GEOMETRY OR ZERO COEFFICIENT FOR
           SLOT ELEMENT NUMBER **************.

2166  ***  SYSTEM WARNING MESSAGE 2166, MATRIX TO BE PARTITIONED IS OF SIZE
           ********** ROWS BY ********** COLUMNS. ROW PARTITION SIZE IS
           ********** COLUMN PARTITION SIZE IS ********** (INCOMPATIBLE).

2168  ***  SYSTEM WARNING MESSAGE 2168, THE FORM PARAMETER AS GIVEN TO THE
           PARTITIONING MODULE FOR SUB-PARTITION ******** IS INCONSISTENT WITH
           ITS SIZE.  FORM =  **********, SIZE = ********** ROWS BY **********
           COLUMNS.

2170  ***  SYSTEM FATAL MESSAGE 2170, BOTH THE ROW AND COLUMN PARTITIONING
           VECTORS ARE PURGED AND ONLY ONE MAY BE.

2171  ***  SYSTEM WARNING MESSAGE 2171, SYM FLAG INDICATES TO THE PARTITION OR
           MERGE MODULE THAT A SYMMETRIC MATRIX IS TO BE OUTPUT. THE
           PARTITIONING VECTORS ******** HOWEVER DO NOT CONTAIN AN IDENTICAL
           NUMBER OF ZEROS AND NON-ZEROS.

2172  ***  SYSTEM WARNING MESSAGE 2172, ROW AND COLUMN PARTITIONING VECTORS DO
           NOT HAVE IDENTICAL ORDERING OF ZERO AND NON-ZERO ELEMENTS, AND SYM
           FLAG INDICATES THAT A SYMMETRIC PARTITION OR MERGE IS TO BE
           PERFORMED.

2173  ***  SYSTEM WARNING MESSAGE 2173, PARTITIONING VECTOR FILE **** CONTAINS
           ********** COLUMNS. ONLY THE FIRST COLUMN IS BEING USED.

2174  ***  SYSTEM WARNING MESSAGE 2174, PARTITIONING VECTOR ON FILE **** IS NOT
           REAL-SINGLE OR REAL-DOUBLE PRECISION.

2175  ***  SYSTEM FATAL MESSAGE 2175, THE RON POSITION OF AN ELEMENT OF A COLUMN
           ON FILE **** IS GREATER THAN NUMBER OF ROWS SPECIFIED BY TRAILER.

2176  ***  SYSTEM FATAL MESSAGE 2176, FILE **** EXISTS BUT IS EMPTY.

2177  ***  USER INFORMATION MESSAGE 2177, SPILL WILL OCCUR IN UNSYMMETRIC
           DECOMPOSITION. ADDITIONAL WORDS NEEDED TO STAY IN CORE.

2178  ***  SYSTEM FATAL MESSAGE 2178, GINO REFERENCE NAMES, IMPROPER FOR
           SUBROUTINE FILSWI.

2179  ***  SYSTEM FATAL MESSAGE 2179, ERROR DETECTED IN FUNCTION FORFIL ****,
           **** NOT IN FIST.

2180  ***  USER WARNING MESSAGE 2180, SYMMETRIC DECOMPOSITION OF A MATRIX WHOSE
           FORM IS SQUARE (BUT NOT SYMMETRIC) WILL BE ATTEMPTED.

2182  ***  USER WARNING MESSAGE 2182, SUBROUTINE ******** IS DUMMY. ONLY ONE OF
           THESE MESSAGES WILL APPEAR PER OVERLAY OF THIS DECK.

2183  ***  USER WARNING MESSAGE 2183, SYMMETRIC DECOMPOSITION OF A MATRIX WHOSE
           FORM IS SQUARE (BUT NOT SYMMETRIC) WILL BE ATTEMPTED.

2184  ***  SYSTEM WARNING MESSAGE 2184, STRESS OR FORCE REQUESTS FOR ELEMENT
           TYPE = ************** WILL NOT BE HONORED AS THIS ELEMENT IS NOT A
           STRUCTURAL ELEMENT.

          Stress and force requests for fluid, mass, damping, PLOTEL, and
          heat boundary elements are automatically ignored.

2187  ***  USER FATAL MESSAGE 2187, INSUFFICIENT WORKING CORE TO HOLD FORTRAN
           LOGICAL RECORD. LENGTH OF WORKING CORE = **********. LENGTH OF
           FORTRAN LOGICAL RECORD = **********.

2190  ***  SYSTEM FATAL MESSAGE 2190, ILLEGAL VALUE FOR KEY =  **********.
           EXPECTED VALUE = **********.

2192  ***  USER FATAL MESSAGE 2192, UNDEFINED GRID POINT ******** IN RIGD*
           ELEMENT ********.

2193  ***  USER FATAL MESSAGE 2193, A REDUNDANT SET OF RIGID BODY MODES WAS
           SPECIFIED FOR THE GENERAL ELEMENT.

          Only a non-redundant list of rigid body modes is allowed to appear
          in the ud set when the S matrix is to be internally calculated in
          subroutine TA1CA.

2194  ***  USER FATAL MESSAGE 2194, A MATRIX D IS SINGULAR IN SUBROUTINE TA1CA.

          While attempting to calculate the [S] matrix for a general element
          in TA1CA, it was discovered that the matrix Dd which relates {ub}
          to {ud} was singular and could not be inverted.

2195  ***  USER WARNING MESSAGE 2195, ILLEGAL VALUE FOR P4 = ******.

2196  ***  USER WARNING MESSAGE 2196, DUMMY SUBROUTINE TIMTS3.
                                      DUMMY SUBROUTINE TIMTS4.
                                      DUMMY SUBROUTINE TIMTS5.

2197  ***  SYSTEM FATAL MESSAGE 2197, ABORT CALLED DURING TIME TEST OF ********.

2198  ***  SYSTEM FATAL MESSAGE 2198, INPUT DATA BLOCK, ******** HAS BEEN PURGED

2199  ***  SYSTEM FATAL MESSAGE 2199, SUMMARY/ ONE OR MORE OF THE ABOVE FATAL
           ERRORS WAS ENCOUNTERED IN SUBROUTINE **********.

2200  ***  USER FATAL MESSAGE 2200, INCONSISTENT RIGID BODY SYSTEM.

2201  ***  USER FATAL MESSAGE 2201, ELEMENT TYPE **** NO LONGER SUPPORTED BY
           SMA1 MODULE. USE EMG AND EMA MODULES FOR ELEMENT MATRIX GENERATION.

2202  ***  USER FATAL MESSAGE 2202, ELEMENT TYPE **** NO LONGER SUPPORTED BY
           SMA2 MODULE. USE EMG AND EMA MODULES FOR ELEMENT MATRIX GENERATION.

2203  ***  SYSTEM FATAL MESSAGE 2203, NULL COLUMN FOUND IN MI FILE DURING
           ASSEMBLY OF **** MATRIX BY GKAM MODULE.

2204  ***  SYSTEM FATAL MESSAGE 2204, UNPACK FOUND NULL COLUMN IN PHIA FILE IN
           GKAM MODULE.

2251  ***  USER WARNING MESSAGE 2251, PHYSICALLY UNREALISTIC VALUE FOR KU ON
           MAT1 CARD ******** VALUE = *************.

2252  ***  USER WARNING MESSAGE 2252, SINGULAR MATRIX OCCURRED WHILE PERFORMING
           SURFACE SPLINE INTERPOLATION IN SUBROUTINE CURVIT. OUTPUT WILL NOT
           APPEAR FOR THE ****-TH GRID ID WRT MATERIAL COORDINATE SYSTEM ID
           ****.

          Matrix developed by SSPLIN could not be inverted. Possibly all the
          points lie on a straight line or not enough points are included.

2257  ***  USER WARNING MESSAGE 2257, SET *** REFERENCED ON SPLINE CARD **** IS
           EMPTY.

          While processing the SET1 or SET2 card referenced on the SPLINE1
          card, no included grid points were found. If SET1 was used, either
          no points were included or they were all scalar points. If SET2 was
          used, the volume of space referenced did not include any structural
          grid points. This may occur if a tapered element is extended too
          far. The spline is omitted from the problem and processing
          continues.

2258  ***  USER FATAL MESSAGE 2258, SET **** REFERENCED ON SPLINE CARD **** NOT
           FOUND OR IT IS EMPTY.

          The necessary SET1 or SET2 card was not found or was empty. Include
          the proper set card or, if it is already included, make sure that
          the set is not empty. (See description under User Warning Message
          2257 shown above.)

2259  ***  SYSTEM FATAL MESSAGE 2259, POINT ASSIGNED TO BOX **** FOR CAERO* ****
           NOT IN EQAERO.

          No internal k point could be found for external box. If box number
          is okay, module APD is in error; if box number is bad, module GI is
          in error.

2260  ***  USER FATAL MESSAGE 2260, SINGULAR MATRIX DEVELOPED WHILE PROCESSING
           SPLINE ****.

          Matrix developed by SSPLIN or LSPLIN (depending on type of spline)
          could not be inverted; possibly for the Surface Spline all points
          lie on a straight line, or not enough points are included.

2261  ***  USER FATAL MESSAGE 2261, PLANE OF LINEAR SPLINE **** PERPENDICULAR TO
           PLANE OF AERO ELEMENT ****.

          Y-axis of linear spline was perpendicular to connected element and
          could not be projected onto element.

2262  ***  USER FATAL MESSAGE 2262, SPLINE **** INCLUDES AERO BOX INCLUDED ON AN
           EARLIER SPLINE.

          Two splines are attached to the same box. Splines may be connected
          to the same structural grid point but not to the same aerodynamic
          grid point. This type of error checking will stop with one error,
          so check this spline and subsequent splines (sorted) for overlaps
          before resubmitting.

2263  ***  USER FATAL MESSAGE 2263, SPLINE3 **** FOR CAERO* HAS ILLEGAL
           COMPONENT.

          Refer to the description of the SPLINE3 card in Section 2.4 for the
          correct value for the component of motion to be interpolated.

2264  ***  SYSTEM FATAL MESSAGE 2264, NUMBER OF ROWS COMPUTED (****) WAS GREATER
           THAN SIZE REQUESTED FOR OUTPUT MATRIX (****).

          Module ADD determines size of output matrices (j set size). Sum of
          number of rows added by different method totals more than maximum
          allowed.

2265  ***  USER FATAL MESSAGE 2265, METHOD **** FOR AEROELASTIC MATRIX
           GENERATION IS NOT IMPLEMENTED.

          A non-implemented method for computing these matrices was input.

2266  ***  USER FATAL MESSAGE 2266, ONE OR MORE OF THE FOLLOWING FLFACT SETS
           WERE NOT FOUND **** ****.

          One or more of the FLFACT IDs on the flutter data card could not be
          found. Include all sets mentioned.

2267  ***  USER FATAL MESSAGE 2267, INTERPOLATION METHOD **** UNKNOWN.

          Matrix interpolation method on FLUTTER card is not implemented.

2268  ***  USER FATAL MESSAGE 2268, FMETHOD SET **** NOT FOUND.

          FLUTTER data card for FMETHOD = **** in Case Control could not be
          found.

2269  ***  USER FATAL MESSAGE 2269, FLUTTER METHOD **** NOT IMPLEMENTED.

          Flutter analysis method on FLUTTER data card is not implemented.

2269A ***  USER FATAL MESSAGE 2269A, FLUTTER METHOD **** NOT IMPLEMENTED WITH B
           MATRIX.

          The KE method cannot be requested when structural damping is
          included.

2270  ***  USER FATAL MESSAGE 2270, LINEAR INTERPOLATION WITHOUT ENOUGH
           INDEPENDENT MACH NUMBERS EQUAL TO DEPENDENT MACH ****.

          Linear interpolation is for points with the same Mach number, and
          less than two were found from the QHHL list which matched the
          requested Mach on an FLFACT list.

2271  ***  USER FATAL MESSAGE 2271, INTERPOLATION MATRIX IS SINGULAR.

          Possibly for the surface spline, all the Mach numbers were the
          same, or for either method, not enough points were included.

2272  ***  USER INFORMATION MESSAGE 2272, NO FLUTTER CALCULATIONS CAN BE MADE IN
           MODULE ADR SINCE BOV = 0.0.

2273  ***  USER FATAL MESSAGE 2273, CAERO2 ******** NOT INPUT IN Z, ZY, Z
           SEQUENCE.

          The EID for z-bodies, zy-bodies, and y-bodies must be ordered in an
          increasing sequence following the EID of a panel on a CAERO1 card.

2274  ***  USER FATAL MESSAGE 2274, ASSOCIATED BODY ******** WAS NOT FOUND WITH
           CAERO2 GROUP ********.

          Aerodynamic bodies must be assigned to an interference group.

2275  ***  USER FATAL MESSAGE 2275, CAERO2 ******** HAS INCONSISTENT USE FOR THI
           OR THN, OR LTH2 IS REQUIRED.

          A conflict exists between the data on a CAERO2 card and a PAERO2
          card.

2276  ***  USER FATAL MESSAGE 2276, THI1 AND THN1 REQUIRED FOR CAERO2 ********.

          Required data on a PAERO2 card not found for the referenced CAERO2
          card.

2277  ***  USER FATAL MESSAGE 2277, CAERO2 BODY ******** DOES NOT HAVE ENOUGH
           SLENDER ELEMENTS.

          At least two slender body elements are required.

2278  ***  USER FATAL MESSAGE 2278, PLANFORM GEOMETRY FOR CAERO3 ID ******** IS
           IN ERROR, CHECK SWEEP ANGLE FOR LEADING EDGE OR CONTROL SURFACE HINGE
           LINE.

2279  ***  SYSTEM INFORMATION MESSAGE 2279, **** ITERATIONS ON LOOP, **** FOUND,
           **** ROOTS WANTED, **** THIS LOOP STOPPED.

2288  ***  SYSTEM FATAL MESSAGE 2288, **** READ INCORRECT NUMBER WORDS (****
           ****).

          Subroutine **** read **** words on the **** card, which is
          incorrect.

2289  ***  USER FATAL MESSAGE 2289, **** INSUFFICIENT CORE (****). **** =
           MATERIAL, **** = POINTERS, **** = ELEMENTS, **** = PROPERTIES.

          Module OPTPR1 or OPTPR2 gives the open core available and the
          pointers to the start of each contiguous section of core.

2290  ***  USER FATAL MESSAGE 2290, THE FOLLOWING ILLEGAL ELEMENT TYPES FOUND ON
           PLIMIT CARD.

          This message is followed by a list of element types. Processing of
          legal element types continues so as to discover other errors.

2291  ***  USER FATAL MESSAGE 2291, PLIMIT RANGE INCORRECT FOR **** THRU ****
           AND **** THRU ****.

          Property identification numbers are repeated. The first pair is
          rejected and processing of the remaining ranges continues in order
          to discover other errors.

2292  ***  USER FATAL MESSAGE 2292, INSUFFICIENT CORE FOR PLIMIT DATA, ELEMENT
           ****, **** WORDS SKIPPED.

          The element type **** being processed exceeded core by **** words.
          Processing of other element types continues in order to discover
          additional requirements.

2293  ***  USER FATAL MESSAGE 2293, NO PID ENTRIES ON PLIMIT CARD (****).

          A PLIMIT card of element type **** had no property entries.

2294  ***  USER FATAL MESSAGE 2294, DUPLICATE **** THRU **** RANGE FOR ELEMENT
           **** REJECTED PLIMIT. SCAN CONTINUED.

          Property identification numbers are repeated for element type ****.

2295  ***  USER FATAL MESSAGE 2295, NO ELEMENTS EXIST FOR OPTIMIZATION.

          A non-null property card and its corresponding material stress
          limit are needed. In subroutine OPT2A stress data is also required.

2296  ***  USER FATAL MESSAGE 2296, INSUFFICIENT CORE **** (****), ELEMENT ****.

          Subroutine **** has insufficient core when loading element type or
          number ****. Elements are read into core by element type (see
          /GPTA1/ sequence), then by sequential element number.

2297  ***  SYSTEM FATAL MESSAGE 2297, INCORRECT LOGIC FOR ELEMENT TYPE ***,
           ELEMENT ****, (****).

          Subroutine (****) has sequential element search. Element type can
          be found in /GPTA1/.

2298  ***  USER FATAL MESSAGE 2298, INSUFFICIENT CORE **** (****), PROPERTY
           ****.

          Subroutine **** (core ****) had insufficient core when loading
          property ****.

2299  ***  SYSTEM FATAL MESSAGE 2299, INCORRECT LOGIC FOR ELEMENT TYPE ***,
           PROPERTY **** (****).

          Subroutine OPTP1B has sequential property search. A property card
          had two entries per card and it was unsorted.

2300  ***  SYSTEM FATAL MESSAGE 2300, **** UNABLE TO LOCATE PROPERTY **** ON EPT
           OR IN CORE.

2301  ***  SYSTEM FATAL MESSAGE 2301, OPTP1D FILE OPTIMIZATION PARAMETER
           INCORRECT AS **** ****.

          Check subroutines OPTPX and OPTP1D use of the scratch file. In
          OPTPR2, the corresponding stress limit(s) is zero.

2302  ***  USER FATAL MESSAGE 2302, SUBROUTINE **** HAS NO PROPERTY OR ELEMENT
           DATA.

2303  ***  USER INFORMATION MESSAGE 2303, OPTPR2 DETECTED ZERO ALPHA FOR
           PROPERTY ****.

          The stress in the element was zero. Only 100 messages per iteration
          may occur.

2304  ***  USER INFORMATION MESSAGE 2304, OPTP2B CONVERGENCE ACHIEVED, HIGHEST
           VALUE IS ****.

2305  ***  USER INFORMATION MESSAGE 2305, OPTPR2 DETECTED NEGATIVE ALPHA FOR
           ELEMENT ****.

          The element did not have stress data or appropriate material stress
          limits. The element properties were not changed. Only 100 of these
          messages will occur per print iteration.

2314  ***  USER INFORMATION MESSAGE 2314, STATISTICS FOR SYMMETRIC
           DECOMPOSITIONS OF DATA BLOCK, **** ****, FOLLOW / NUMBER OF UII .LT.
           0 = ***** / MAXIMUM ABSOLUTE VALUE OF AII/UII = ***** / N1 THRU N6 =
           ****** ****** ****** ****** ****** ****** / ROW NUMBERS OF 5 LARGEST
           AII/UII = ****** ****** ****** ****** ******.

          This message will appear if the NASTRAN card SYSTEM (57)=1 is
          placed before the ID card. See Programmer's Manual Section 3.5.14
          for a discussion of the statistics appearing in the message.

2316  ***  USER INFORMATION MESSAGE 2316, INSUFFICIENT CORE, TO PREPARE
           DECOMPOSITION STATISTICS.

2317  ***  USER WARNING MESSAGE 2317, PARAM HAS STORED OUTSIDE DEFINED RANGE OF
           COMMON BLOCK /SYSTEM/. INDEX VALUE = ********************.

2318  ***  USER FATAL MESSAGE 2318, NO AERO CARD FOUND.

          An AERO card is required to run APD.

2319  ***  USER FATAL MESSAGE 2319, NO CAERO* CARDS FOUND.

          At least one CAEROi card is required for APD.

2320  ***  USER FATAL MESSAGE 2320, NO AEFACT CARDS FOUND.

          An AEFACT has been referenced and none has been found in the input.

2321  ***  USER FATAL MESSAGE 2321, NO FLUTTER CARDS FOUND.

          Flutter analysis requires at least one FLUTTER card.

2322  ***  USER FATAL MESSAGE 2322, NEITHER MKAERO1 OR MKAERO2 CARDS FOUND.

          Either MKAERO1 or MKAERO2 cards are required.

2323  ***  USER FATAL MESSAGE 2323, PAERO* CARD NO. ******** REFERENCED BY
           CAERO* CARD NO. BUT DOES NOT EXIST.

          CAEROi card points to missing PAEROi card.

2324  ***  USER FATAL MESSAGE 2324, CAERO* ELEMENT NO. ******** REFERENCED ON A
           SPLINE* CARD DOES NOT EXIST.

          Either a SPLINE1, a SPLINE2, or a SPLINE3 card references a CAEROi
          card which is missing.

2325  ***  USER FATAL MESSAGE 2325, CAERO* ELEMENT NO. ******** REFERENCED ON A
           SET2 CARD DOES NOT EXIST.

          A SET2 card points to a CAEROi which was not included.

2326  ***  USER FATAL MESSAGE 2326, CAERO* ELEMENT NO. ******** REFERENCES
           AEFACT CARD NO. ******** WHICH DOES NOT EXIST.

          The listed CAEROi card requires one AEFACT card for LSPAN.

2327  ***  USER FATAL MESSAGE 2327, CAERO* ELEMENT NO. ******** REFERENCES
           AEFACT CARD NO. ******** WHICH DOES NOT EXIST.

          The listed CAEROi card requires one AEFACT card for LCHORD.

2328  ***  USER FATAL MESSAGE 2328, SET* AND SPLINE* CARDS REQUIRED.

          At least one SET1 or SET2 card and at least one SPLINE1, SPLINE2,
          or SPLINE3 card required.

2329  ***  USER FATAL MESSAGE 2329, DUPLICATE EXTERNAL ID NO. ********
           GENERATED.

          The external IDs assigned to each generated box must be unique.

2330  ***  USER FATAL MESSAGE 2330, SET1 OR SPLINE3 CARD NO. ******** REFERENCES
           EXTERNAL ID NO. ******** WHICH DOES NOT EXIST.

          External grid point IDs referenced on a SET1 or SPLINE3 card do not
          exist as structural grid points.

2331  ***  USER FATAL MESSAGE 2331, BOX PICKED ON SPLINE CARD NO. ******** NOT
           GENERATED BY CAERO CARD NO. ********.

          SPLINE card ******** points to a box which was not generated by the
          CAEROi card.

2332  ***  USER WARNING MESSAGE 2332, INVALID INPUT DATA DETECTED IN DATA BLOCK,
           ****, PROCESSING STOPPED FOR THIS DATA BLOCK.

2333  ***  SYSTEM INFORMATION MESSAGE 2333, MODULE DDRMM TERMINATED WITH
           VARIABLE IERROR = **********.

2334  ***  SYSTEM WARNING MESSAGE 2334, ILLEGAL MAJOR OR MINOR OFP-ID
           IDENTIFICATIONS = ********** ********** DETECTED IN DATA BLOCK, ****,
           PROCESSING OF SAID DATA BLOCK DISCONTINUED.

2335  ***  SYSTEM WARNING MESSAGE 2335, THE AMOUNT OF DATA IS NOT CONSISTENT FOR
           EACH EIGENVALUE IN DATA BLOCK **** PROCESSING OF THIS DATA BLOCK
           TERMINATED.

2336  ***  SYSTEM WARNING MESSAGE 2336, A CHANGE IN WORD 2 OF THE OFP-ID RECORDS
           OF DATA BLOCK **** HAS BEEN DETECTED. PROCESSING OF THIS DATA BLOCK
           HAS BEEN TERMINATED.

2337  ***  USER WARNING MESSAGE 2337, DATA BLOCK **** CAN NOT BE PROCESSED DUE
           TO A CORE INSUFFICIENCY OF APPROXIMATELY ********** DECIMAL WORDS.

2338  ***  USER WARNING MESSAGE 2338, DATA BLOCK **** MAY NOT BE FULLY COMPLETED
           DUE TO A CORE INSUFFICIENCY OF APPROXIMATELY ********** DECIMAL
           WORDS.

2339  ***  SYSTEM WARNING MESSAGE 2339, A CHANGE IN WORD 2 OF THE OFP-ID RECORDS
           OF DATA BLOCK **** HAS BEEN DETECTED. PROCESSING OF THIS DATA BLOCK
           HAS BEEN TERMINATED.

2340  ***  USER WARNING MESSAGE 2340, MODULE **** ****, HAS BEEN REQUESTED TO DO
           UNSYMMETRIC DECOMPOSITION OF A SYMMETRIC MATRIX.

2341  ***  USER WARNING MESSAGE 2341, MODULE **** **** HAS BEEN FURNISHED A
           SQUARE MATRIX MARKED UNSYMMETRIC FOR SYMMETRIC DECOMPOSITION.

2342  ***  USER WARNING MESSAGE 2342, UNRECOGNIZED APPROACH PARAMETER ********
           IN GPFDR INSTRUCTION.

          The solution approach parameter can only be STATICS, REIGEN, DS0,
          DS1, FREQ, TRAN, BLK0, BLK1, CEIGEN, or PLA, corresponding to the
          Rigid Format used.

2343  ***  SYSTEM WARNING MESSAGE 2343, DATA BLOCK, *****, IS EITHER NOT
           -EQEXIN- OR POSSIBLY INCORRECT.

2344  ***  SYSTEM WARNING MESSAGE 2344, GPFDR FINDS ELEMENT = **** ****, HAS AN
           ECT ENTRY LENGTH TOO LONG FOR A PROGRAM LOCAL ARRAY.

2345  ***  SYSTEM WARNING MESSAGE 2345, GPFDR FINDS AND IS IGNORING UNDEFINED
           ECT DATA WITH LOCATE NUMBERS = ******** ******** ********.

2346  ***  SYSTEM WARNING MESSAGE 2346, GPFDR FINDS DATA FOR EL-TYPE =
           **********, IN DATA BLOCK, ********** NOT TO BE IN AGREEMENT WITH
           THAT WHICH IS EXPECTED.

2347  ***  USER WARNING MESSAGE 2347, GPFDR FINDS TOO MANY ACTIVE CONNECTING
           GRID POINTS FOR ELEMENT ID = **********.

2348  ***  SYSTEM WARNING MESSAGE 2348, GPFDR DOES NOT UNDERSTAND THE MATRIX-
           DICTIONARY ENTRY FOR ELEMENT ID = **********.

2349  ***  SYSTEM WARNING MESSAGE 2349, GPFDR FINDS AN ELEMENT ENTRY CONNECTING
           PIVOT SIL = ********** ON DATA BLOCK ***** TOO LARGE FOR A LOCAL
           ARRAY. ENTRY IS BEING IGNORED.

2350  ***  SYSTEM WARNING MESSAGE 2350, GPFDR CANNOT FIND PIVOT SIL =
           **********, AMONG THE SILS OF ELEMENT ID = **********, AS READ FROM
           DATA BLOCK, *****, ENTRY THUS IGNORED.

2351  ***  USER INFORMATION MESSAGE 2351, A FORCE CONTRIBUTION DUE TO ELEMENT
           TYPE = **** ****, ON POINT ID = **********, WILL NOT APPEAR IN THE
           GRID-POINT-FORCE-BALANCE SUMMARY.

2352  ***  SYSTEM WARNING MESSAGE 2352, GPFDR IS NOT ABLE TO FIND PIVOT SIL =
           ********** AS READ FROM DATA BLOCK ***** IN TABLE OF SILS.

2353  ***  USER WARNING MESSAGE 2353, INSUFFICIENT CORE TO HOLD ALL NON-ZERO
           APP-LOAD AND F-OF-SPC OUTPUT LINE ENTRIES OF GRIDPOINT-FORCE-BALANCE
           REQUESTS. SOME POINTS REQUESTED FOR OUTPUT WILL BE MISSING THEIR APP-
           LOAD OR F-OF-SPC CONTRIBUTION IN THE PRINTED BALANCE.

2354  ***  SYSTEM WARNING MESSAGE 2354, GPFDR MODULE IS UNABLE TO CONTINUE AND
           HAS BEEN TERMINATED DUE TO ERROR MESSAGE PRINTED ABOVE OR BELOW THIS
           MESSAGE. THIS ERROR OCCURRED IN GPFDR CODE WHERE THE VARIABLE -
           NERROR- WAS SET = *****.

2355  ***  USER FATAL MESSAGE 2355, GRID POINT COORDINATES OF ELEMENT **********
           ARE IN ERROR. ONE OR MORE OF THE R-COORDINATES ARE ZERO OR NEGATIVE.

2357  ***  USER WARNING MESSAGE 2357, ONE VECTOR (DEFAULT) WILL BE COMPUTED IN
           THE COMPLEX REGION.

          If more than one vector is desired from the Hessenburg method, make
          a specific request on the EIGC card.

2358  ***  USER WARNING MESSAGE 2358, SYMMETRIC SCRIPT-AF MATRIX (HREE) ASSUMED
           IN RADMTX.

2359  ***  USER WARNING MESSAGE 2359, COL *****, ROW ***** OF RADMTX IS
           NEGATIVE.

2360  ***  USER FATAL MESSAGE 2360, TOTAL VIEW FACTOR (FA/A), FOR ELEMENT
           ******** IS **************** (ELEMENT AREA IS ****************).

          Provides view factors and areas for all elements with a view factor
          greater than 1.01. This message is also a WARNING for all elements
          with a view factor between .99 and 1.01, provided the NASTRAN card
          SYSTEM(58)=1 is included in the deck.

2361  ***  USER INFORMATION MESSAGE 2361, **** ELEMENTS HAVE A TOTAL VIEW FACTOR
           (FA/A) LESS THAN 0.99, ENERGY MAY BE LOST TO SPACE.

          Provides the total number of elements with a view factor less than
          .99.

2362  ***  USER FATAL MESSAGE 2362, CHBDY CARDS WITH DUPLICATE IDS FOUND IN EST,
           CHBDY ID NUMBER = **********.

2363  ***  SYSTEM WARNING MESSAGE 2363, SSG2B FORCED MPYAD COMPATIBILITY OF
           MATRIX ON ***** FROM (*****, *****) TO (*****, *****).

          This message identifies a matrix and its initial size (row, column)
          and its changed size (row, column) so that it is compatible with
          MPYAD operations.

2364  ***  USER FATAL MESSAGE 2364, GRID POINT COORDINATES OF ELEMENT ********
           ARE IN ERROR. ONE OR MORE OF THE THETA-COORDINATES ARE NONZERO.

2365  ***  USER WARNING MESSAGE 2365, INSUFFICIENT CORE FOR HESSENBURG METHOD.
           SWITCHING TO INVERSE POWER.

2366  ***  USER FATAL MESSAGE 2366, REGION IMPROPERLY DEFINED ON EIGC CARD.

          If insufficient core has caused an automatic switch from Hessenburg
          method to Inverse Power method, the EIGC card must have the
          region(s) defined (they are ignored for the Hessenburg method).
          Either increase core to use the Hessenburg method or define the
          region(s) for Inverse Power.

2367  ***  USER WARNING MESSAGE 2367, FREQUENCY F1 (FIELD 4) ON THE EIGR BULK
           DATA CARD IS NEGATIVE. IT IS ASSUMED TO BE ZERO FOR CALCULATION
           PURPOSES.

2369  ***  USER WARNING MESSAGE 2369, WHEEL MUST HAVE FEWER THAN 256 SPOKES.
           INPUT MODULE RESETTING TO 255.

          See Section 2.6 for a discussion of INPUT module sample 8.

2370  ***  USER WARNING MESSAGE 2370, MULTIPOINT CONSTRAINT FORCES NOT
           CALCULATED IN ****** DUE TO MISSING INPUT FILE.

2371  ***  USER WARNING MESSAGE 2371, EQUILIBRIUM FORCES NOT CALCULATED IN
           ****** DUE TO MISSING INPUT FILE.

2372  ***  USER WARNING MESSAGE 2372, ****** IS UNABLE TO CALCULATE RIGID BODY
           TRANSFORMATION FOR SCALAR MODEL.

2373  ***  USER WARNING MESSAGE 2373, ONLY SORT1-REAL SUPPORTED IN ********.

2374  ***  USER WARNING MESSAGE 2374, INSUFFICIENT CORE TO PROCESS MORE THAN
           **** VECTORS IN ****.

          Output module EQMCK needs 6 words for loads, MPCs, and SPCs for
          each subcase or eigenvalue plus 2 (statics) or 3 (eigenvalue)
          buffers.

2375  ***  SYSTEM WARNING MESSAGE 2375, MODULE ******** HAS BEEN REQUESTED TO
           DECOMPOSE A RECTANGULAR MATRIX.

          Symmetric decomposition will not accept rectangular matrix input.

2376  ***  USER WARNING MESSAGE 2376, INSUFFICIENT CORE IN ****. HAS ****, NEEDS
           ****.

2377  ***  USER WARNING MESSAGE 2377A, MATRIX CONDITIONING ERRORS GIVEN WITH
(A)        EXTERNAL ID.

2377  ***  USER WARNING MESSAGE 2377B, MATRIX CONDITIONING ERRORS GIVEN WITH
(B)        INTERNAL ID.

          Symmetric decomposition diagnostics follow. Both the input and
          decomposed diagonal are printed. Only available when module SDCMPS
          is used.

2378  ***  USER INFORMATION MESSAGE 2378, **** ESTIMATE OF CPU TIME FOR MT=****,
           PASSIVE COL.=****, ACTIVE COL.=****, SPILL=****.

          Seconds of CPU time for each of the above operations is given when
          module SDCMPS is used.

2379  ***  SYSTEM FATAL MESSAGE 2379, LOGIC ****** ERROR IN SDCMPS.

2380  ***  USER WARNING MESSAGE 2380, MULTIPOINT CONSTRAINT FORCES NOT OUTPUT IN
           ******, SEE QUEUED MESSAGES.

          Other message(s) follow(s) indicating the reason(s) why a request
          for MPCFORCE in the Case Control Deck is being ignored.

2381  ***  SYSTEM FATAL MESSAGE 2381, LOGIC ERROR ****** IN SDCMPS. CONTENTS OF
           /SDCOMX/ FOLLOW --

2382  ***  USER WARNING MESSAGE 2382, ELEMENT MATRICES FOR ELEMENTS CONGRUENT TO
           ELEMENT ID = ********** WILL BE RE-COMPUTED AS THERE IS INSUFFICIENT
           CORE AT THIS TIME TO HOLD CONGRUENCY MAPPING DATA. ADDITIONAL CORE
           NEEDED = **** WORDS.

2383  ***  SYSTEM WARNING MESSAGE 2383, UNABLE TO LOCATE CONGRUENCY MAPPING DATA
           FOR ELEMENT ID = **********. ELEMENT MATRICES FOR THIS ELEMENT WILL,
           THEREFORE, BE RE-COMPUTED.

2384  ***  USER WARNING MESSAGE 2384, CONGRUENCY OF ELEMENT ID = ********** WILL
           BE IGNORED AND ITS ELEMENT MATRICES WILL BE RE-COMPUTED AS THERE IS
           INSUFFICIENT CORE AT THIS TIME TO PERFORM CONGRUENCY MAPPING
           COMPUTATIONS. ADDITIONAL CORE NEEDED = **** WORDS.

2385  ***  USER WARNING MESSAGE 2385, DESIRED NUMBER OF EIGENVALUES EXCEED THE
           EXISTING NUMBER, ALL EIGENSOLUTIONS WILL BE SOUGHT.

          The desired number of eigenvalues specified on the EIGB card (NEP)
          or the EIGR card (ND) exceeds the rank of the [Kdaa] or [Maa]
          matrix.

2386  ***  USER FATAL MESSAGE 2386, STIFFNESS MATRIX SINGULARITY CANNOT BE
           REMOVED BY SHIFTING.

          Check the specification of masses on CONM1, CONM2, CMASSi, material
          definition, and element property cards to ensure that the
          degrees-of-freedom in the analysis set are not all massless.

2387  ***  USER WARNING MESSAGE 2387, PROBLEM SIZE REDUCED TO **** DUE TO
           ORTHOGANILITY DRIFT OR NULL TRIAL VECTOR. ALL EXISTING MODES MAY HAVE
           BEEN OBTAINED. USE DIAG 16 TO DETERMINE ERROR BOUNDS.

          The Tridiagonal Reduction method cannot generate a reduced problem
          size of the order prescribed in Section 10.6.2.3 of the Theoretical
          Manual. However, the desired number of accurate eigenvalues
          specified on the EIGB card (NEP) or the EIGR card (ND) may have
          been obtained. A detailed list of the computed error bounds could
          have been obtained by requesting DIAG 16 in the Executive Control
          Deck.

2388  ***  USER WARNING MESSAGE 2388, USER SPECIFIED RANGE NOT USED FOR FEER
           BUCKLING, THE ROOTS OF LOWEST MAGNITUDE ARE OBTAINED.

          The value of L1 specified on the EIGB card is ignored for buckling
          analysis by the Tridiagonal Reduction (FEER) method.

2389  ***  USER WARNING MESSAGE 2389, PROBLEM SIZE REDUCED. NO MORE TRIAL
           VECTORS CAN BE OBTAINED.

          The desired number of eigenvalues specified on the EIGB card (NEP)
          or the EIGR card (ND) exceeds the number that can be calculated by
          the Tridiagonal Reduction (FEER) method. Check whether the
          requested number of eigenvalues exceeds the rank of the [Kdaa] or
          [Maa] matrix, which equals the number of existing eigenvalues.

2390  ***  USER WARNING MESSAGE 2390, **** FEWER ACCURATE EIGENSOLUTIONS THAN
           THE **** REQUESTED HAVE BEEN FOUND. USE DIAG 16 TO DETERMINE ERROR
           BOUNDS.

          The number of eigenvalues passing the eigenvalue relative-error
          test is less than the number requested on the EIGB or EIGR card.
          The maximum allowable error is specified in field 5 on the above
          cards. A detailed list of the computed error bounds could have been
          obtained by requesting DIAG 16 in the Executive Control Deck. A
          checkpoint and restart should be employed to obtain additional
          accurate eigensolutions.

2391  ***  SYSTEM FATAL MESSAGE 2391, PROGRAM LOGIC ERROR IN FEER.

          An unexpected EOF or word count has been encountered. This is
          caused by a conflict between subroutine FCNTL and GINO.

2392  ***  USER INFORMATION MESSAGE 2392, **** MORE ACCURATE EIGENSOLUTIONS THAN
           THE **** REQUESTED HAVE BEEN FOUND. USE DIAG 16 TO DETERMINE ERROR
           BOUNDS.

          The number of eigenvalues passing the eigenvalue relative-error
          test is greater than the number requested on the EIGB or EIGR card.
          The maximum allowable error is specified in field 5 on the above
          cards. A detailed list of the computed error bounds could have been
          obtained by requesting DIAG 16 in the Executive Control Deck.

2393  ***  USER WARNING MESSAGE 2393, THE REDUCED-SYSTEM EIGENVECTOR
           CORRESPONDING TO EIGENVALUE **** DOES NOT MEET CONVERGENCE CRITERION.
           ABSOLUTE RELATIVE ERROR BETWEEN SUCCESSIVE ITERATES IS ****.

          The accuracy of the corresponding physical eigenvector is in doubt.
          Refer to the Eigenvalue Summary Table for the largest error in the
          generalized mass matrix.

2396  ***  USER WARNING MESSAGE 2396, SDCOMP COMPUTED A ZERO ON THE DIAGONAL. A
           VALUE OF 1.0E-10 WILL BE USED. THE ACCURACY OF THE DECOMPOSITION MAY
           BE IN DOUBT.

          The matrix being decomposed is singular or a diagonal element is
          less than zero in the case of Cholesky decomposition.

2397  ***  USER FATAL MESSAGE 2397, INVALID TO HAVE AN O-SET WITH A NULL A-SET.

          There must be at least one degree of freedom in the A-SET even
          though EPOINTS may be present.

2398  ***  USER FATAL MESSAGE 2398, MPYAD REQUIRES SIGN OF A*B TO BE -1, 0 OR
           +1.

2399  ***  USER WARNING MESSAGE 2399, ONLY THE FIRST ***** EIGENSOLUTIONS
           CLOSEST TO THE SHIFT POINT (F1 OR ZERO) PASS THE FEER ACCURACY TEST
           FOR EIGENVECTORS.

2401  ***  USER WARNING MESSAGE 2401, ******** MATRIX IS NULL. AN ARBITRARY
           VALUE OF 1.0 IS THEREFORE ASSIGNED TO THE RIGID BODY ERROR RATIO
           (EPSILON SUB E).

2402  ***  USER FATAL MESSAGE 2402, NULL DIFFERENTIAL STIFFNESS MATRIX GENERATED
           IN SUBROUTINE DS1A.

2404  ***  USER FATAL MESSAGE 2404, GRID POINTS 1 AND 3 OF TRIM6 WITH ELEMENT ID
           = ******** HAVE SAME COORDINATES.

2405  ***  USER FATAL MESSAGE 2405, GRID POINTS 1, 3, AND 5 APPEAR TO BE ON A
           STRAIGHT LINE. ELEMENT TRIM6 WITH ID = ********.

2406  ***  USER FATAL MESSAGE 2406, GRID POINTS 1 AND 5 HAVE SAME COORDINATES.
           ELEMENT TRIM6 WITH ID = ********.

2407  ***  USER FATAL MESSAGE 2407, MATRIX RELATING GENERALIZED PARAMETERS AND
           GRID POINT DISPLACEMENTS IS SINGULAR. CHECK COORDINATES OF ELEMENT
           TRIM6 WITH ID = ********.

2408  ***  USER FATAL MESSAGE 2408, GRID POINTS 1 AND 3 OF TRPLT1 WITH ELEMENT
           ID = ******** HAVE SAME COORDINATES.

2409  ***  USER FATAL MESSAGE 2409, GRID POINTS 1, 3, AND 5 APPEAR TO BE ON A
           STRAIGHT LINE. ELEMENT TRPLT1 WITH ID = ********.

2410  ***  USER FATAL MESSAGE 2410, GRID POINTS 1 AND 5 HAVE SAME COORDINATES.
           ELEMENT TRPLT1 WITH ID = ********.

2411  ***  USER FATAL MESSAGE 2411, MATRIX RELATING GENERALIZED PARAMETERS AND
           GRID POINT DISPLACEMENTS IS SINGULAR. CHECK COORDINATES OF ELEMENT
           TRPLT1 WITH ID = ********.

2412  ***  USER FATAL MESSAGE 2412, A SINGULAR MATERIAL MATRIX FOR ELEMENT ID =
           ******** HAS BEEN DETECTED BY SUBROUTINE TLODT1 WHILE TRYING TO
           COMPUTE THERMAL LOADS WITH TEMPP2 CARD DATA.

          The thermal load vector generated by TEMPP2 data is not correctly
          applied to a TRPLT1 element.

2413  ***  USER FATAL MESSAGE 2413, GRID POINTS 1 AND 3 OF TRSHL WITH ELEMENT ID
           = ******** HAVE SAME COORDINATES.

2414  ***  USER FATAL MESSAGE 2414, GRID POINTS 1, 3, AND 5 APPEAR TO BE ON A
           STRAIGHT LINE. ELEMENT TRSHL WITH ID = ********.

2415  ***  USER FATAL MESSAGE 2415, GRID POINTS 1 AND 5 HAVE SAME COORDINATES.
           ELEMENT TRSHL WITH ID = ********.

2416  ***  USER FATAL MESSAGE 2416, MATRIX RELATING GENERALIZED PARAMETERS AND
           GRID POINT DISPLACEMENTS IS SINGULAR. CHECK COORDINATES OF ELEMENT
           TRSHL WITH ID = ********.

2417  ***  USER FATAL MESSAGE 2417, A SINGULAR MATERIAL MATRIX FOR ELEMENT ID =
           ******** HAS BEEN DETECTED BY SUBROUTINE TLODSL WHILE TRYING TO
           COMPUTE THERMAL LOADS WITH TEMPP2 CARD DATA.

          The thermal load vector generated by TEMPP2 data is not correctly
          applied to TRSHL element.

2418  ***  USER FATAL MESSAGE 2418, MATERIAL ID FOR MEMBRANE EFFECTS IS LESS
           THAN OR EQUAL TO ZERO FOR TRSHL ELEMENT WITH ID = ********.

2419  ***  SYSTEM FATAL MESSAGE 2419, PIVOT POINT IS NOT EQUAL TO TRSHL ELEMENT
           GRID POINTS FOR ELEMENT ID = ********.

          An error in the coordinate system transformation has occurred.
          Temporary avoidance: remove coordinate system ID from field 7 of
          the GRID (or GRDSET) card.

2422  ***  USER WARNING MESSAGE 2422, VISC DATA NOT PROCESSED BY EMGPRO.

          CVISC data cards are used only in the direct method of dynamic
          problem formulations (DISP Rigid Formats 7, 8, and 9). A warning is
          issued when these cards are encountered in the modal method of
          dynamic problem formulations (DISP Rigid Formats 10, 11, and 12).

2423  ***  USER FATAL MESSAGE 2423, DEPENDENT COMPONENT SPECIFIED MORE THAN ONCE
           ON MPC CARDS AND/OR IN RIGID ELEMENTS. SIL VALUE = ********.

          The use of DIAG 21 in the Executive Control Deck will show the SIL
          (internal DOF) corresponding to the duplicated component.

2424  ***  USER FATAL MESSAGE 2424, MACH BOX CONTROL POINTS IMPROPER. SINGULAR
           MATRIX RESULTED.

2425  ***  USER FATAL MESSAGE 2425, MACH BOX GENERATION OF BOXES FAILED.

2426  ***  USER FATAL MESSAGE 2426, MACH NUMBER ********** WAS NOT FOUND ON
           AEFACT CARD ********.

2427  ***  USER FATAL MESSAGE 2427, SINGULAR MATRIX FOR INTERPOLATION IN
           ********.

2428  ***  USER FATAL MESSAGE 2428, MACH NUMBER ********** WAS NOT FOUND IN
           PISTON THEORY ALPHA ARRAY.

2429  ***  USER FATAL MESSAGE 2429, WRONG NUMBER OF WORDS OR CARD NOT FOUND FOR
           CARD ID ******** ASSOCIATED WITH CAERO* ID ********.

2430  ***  SYSTEM WARNING MESSAGE 2430, REQUESTED ******** PRECISION ******** BY
           ********, ******** IS LOGICAL CHOICE.

          This message is issued when single or double precision is
          prescribed for a matrix utility module but could be better
          prescribed based on the data.

2431  ***  SYSTEM WARNING MESSAGE 2431, REQUESTED TYPE ******** BY ********.
           TYPE ******** IS LOGICAL CHOICE.

          This message is issued when real or complex output is prescribed
          for a matrix utility module but should be prescribed as indicated.

2432  ***  USER INFORMATION MESSAGE 2432, DIAG 19 MPYAD SUMMARY.

          Information on next two lines is MPYAD matrix data summary listed
          on system output file on CDC and UNIVAC or on log file (Unit 4) on
          IBM and VAX.

2433  ***  USER INFORMATION MESSAGE 2433, MPYAD METHOD ****, NBR PASSES = ****,
           EST TIME = ****.

          DIAG 19 MPYAD Method Summary listed on system output file on CDC
          and UNIVAC or on log file (Unit 4) on IBM and VAX.

2434  ***  USER INFORMATION MESSAGE 2434, MPYAD -- NULL MATRIX PRODUCT.

          DIAG 19 MPYAD message.

=PAGE=
6.5  FUNCTIONAL MODULE MESSAGES (3001 THROUGH 4000)

3001  ***  SYSTEM FATAL MESSAGE 3001, ATTEMPT TO OPEN DATA SET *** IN SUBROUTINE
           WHICH WAS NOT DEFINED IN FIST.

          Subroutine did not expect data block to be purged. Check data block
          requirements for module. This message is also a WARNING when STRESS
          output is requested in a heat transfer problem.

3002  ***  SYSTEM FATAL MESSAGE 3002, EOF ENCOUNTERED WHILE READING DATA SET
           ********(FILE ***) IN SUBROUTINE ******.

          This message is issued when an end-of-file occurs while trying to
          skip the header record. The data block is not in the proper format.

3003  ***  SYSTEM FATAL MESSAGE 3003, ATTEMPT TO READ PAST THE END OF A LOGICAL
           RECORD IN DATA SET ********(FILE ***) IN SUBROUTINE ********.

          This message is issued when the file is positioned at the beginning
          of a logical record and the record does not contain at least three
          words. Data block is not in proper format.

3004  ***  SYSTEM FATAL MESSAGE 3004, INCONSISTENT TYPE FLAGS ENCOUNTERED WHILE
           PACKING DATA SET ****.

3005  ***  USER FATAL MESSAGE 3005, ATTEMPT TO OPERATE ON SINGULAR MATRIX ****
           IN SUBROUTINE ****.

          A diagonal term does not exist for a column of (U). This is
          normally detected in DECOMP, implying care was not taken in
          processing singular matrices in the calling routine.

3006  ***  SYSTEM FATAL MESSAGE 3006, BUFFER ASSIGNED WHEN OPENING DATA BLOCK
           **** FILE (****) CONFLICTS WITH BUFFERS CURRENTLY OPEN.

          Computation of buffer pointers or allocation of open core is in
          error.

3007  ***  SYSTEM FATAL MESSAGE 3007, ILLEGAL INPUT TO SUBROUTINE ****.

          Subroutine **** has encountered data which it cannot process. This
          error should not be caused by user input data. A system or
          programming error is indicated. Go directly to the subroutine
          listing or description to determine the exact cause of the problem.

3008  ***  SYSTEM FATAL MESSAGE 3008, INSUFFICIENT CORE AVAILABLE FOR SUBROUTINE
           ********. ADDITIONAL CORE REQUIRED = **** WORDS.

          Insufficient open core was available to meet the needs of the
          subroutine indicated. Increase Region Size, Field Length, HICORE
          allocation, or the length of the open core COMMON block, depending
          on the machine being used.

3009  ***  SYSTEM FATAL MESSAGE 3009, DATA TRANSMISSION ERROR ON DATA SET
           ******** (FILE ***)

          A conflict exists between the SGINO subroutine for the UNIVAC 1108
          and the resident NTRAN$. Either record SGINO or remove the PLOT
          request from the NASTRAN job.

3010  ***  SYSTEM FATAL MESSAGE 3010, ATTEMPT TO MANIPULATE DATA SET ********
           (FILE ***) BEFORE OPENING FILE.

          An operation other than OPEN or CLOSE is requested on a file which
          is not defined in the FIST.

3011  ***  SYSTEM FATAL MESSAGE 3011, ATTEMPT TO WRITE A TRAILER ON FILE ***
           WHEN IT HAS BEEN PURGED.

          The file did not exist in the FIST when WRTTRL was called.

3012  ***  SYSTEM FATAL MESSAGE 3012, ATTEMPT TO OPEN DATA SET ******** (FILE
           ***) WHICH HAS ALREADY BEEN OPENED.

          GINO OPEN was called while the file was already open.

3013  ***  SYSTEM FATAL MESSAGE 3013, ATTEMPT TO READ DATA SET ******** (FILE
           ***) WHEN IT WAS OPENED FOR OUTPUT.

          GINO was called to READ a data block opened for output.

3014  ***  SYSTEM FATAL MESSAGE 3014, ATTEMPT TO WRITE DATA SET ******** (FILE
           ***) WHEN IT WAS OPENED FOR INPUT.

          GINO was called to WRITE a data block opened for input.

3015  ***  SYSTEM FATAL MESSAGE 3015, ATTEMPT TO FWDREC ON DATA SET ********
           (FILE ***) WHEN IT WAS OPENED FOR OUTPUT.

          GINO was called to FWDREC a file opened for output.

3016  ***  SYSTEM FATAL MESSAGE 3016, **** MATRIX IS NOT IN PROPER FORM IN
           SUBROUTINE ****.

          The input matrix is not in the proper form or type acceptable to
          the subroutine. Check the trailer information on the matrix and the
          subroutine description for the discrepancy.

3017  ***  USER WARNING MESSAGE 3017, ONE OR MORE GRID POINT SINGULARITIES HAVE
           NOT BEEN REMOVED BY SINGLE OR MULTI-POINT CONSTRAINTS.

          Singularities or near singularities may exist at the grid point
          level. The listed singularities should be examined for data errors.
          The check performed here is neither necessary nor sufficient for a
          singular matrix.

3018  ***  SYSTEM FATAL MESSAGE 3018, MODULE ********, SEQUENCE NO. ***,
           REQUIREMENTS EXCEED AVAILABLE FILES.

          Segment File Allocator (SFA) did not have sufficient logical files
          available to fulfill the request of the module. Cut module
          requirements or increase the logical files within the computer
          system. See Section 5 of the Programmer's Manual.

3019  ***  USER FATAL MESSAGE 3019, MAXIMUM LINE COUNT EXCEEDED IN SUBROUTINE
           **** LINE COUNT EQUALS ****.

          The total number of lines written on the system output file has
          exceeded the set limit (default value is 20,000). If you wish to
          increase this value, include a card of the form "MAXLINES=n" in
          your Case Control Deck.

3020  ***  SYSTEM FATAL MESSAGE 3020, GNFIST OVERFLOWED FIST TABLE AT SEQUENCE
           NO. *** DATA SET ********.

          Generate FIST (GNFIST) routine overflowed FIST /XFIST/. Increase
          compiled size. See Section 2 of the Programmer's Manual.

3021  ***  SYSTEM FATAL MESSAGE 3021, FILE *** NOT DEFINED IN FIST.

          An operation other than OPEN or CLOSE is requested on a file which
          is not defined in the FIST.

3022  ***  SYSTEM WARNING MESSAGE 3022, DATA SET ******** IS REQUIRED AS INPUT
           AND IS NOT OUTPUT BY A PREVIOUS MODULE IN THE CURRENT DMAP ROUTE.

          Segment File Allocator (SFA) detected that an input data block to a
          future module has not been generated. If the future module requires
          that this data block exist, the module may terminate with a fatal
          error.

          This message may occur (and most often does) when the Segment File
          Allocator has removed from its tables (due to a need for more room)
          previously purged data blocks. In this case no error or even a
          warning is implied.

3023  ***  USER INFORMATION MESSAGE 3023--PARAMETERS FOR SYMMETRIC DECOMPOSITION
           OF DATA BLOCK ******** (N = *****) TIME ESTIMATE = ********.

           C AVG = ******        S AVG = ******           PC MAX = ******
           PC AVG = ******       ADDITIONAL CORE = ****** PC GROUPS = ******
           SPILL GROUPS = ****** C MAX ******             PREFACE LOOPS = ******

          N is the number of rows in the data block; TIME is the estimate (in
          seconds) to perform the decomposition; C AVG is the average number
          of active columns per pivot row; PC AVG is the average number of
          passive columns at each active termination point; SPILL GROUPS is
          the number of spill groups; S AVG is the average number of rows in
          each spill group; ADDITIONAL CORE (positive) is the amount of core
          required to avoid spill, (negative) is the amount of unused core; C
          MAX is the maximum number of active columns in any one pivot row;
          PC MAX is the maximum number of passive columns at any one active
          column termination point; PC GROUPS is the number of active column
          termination points; PREFACE LOOPS is the number of times the
          preface of the decomposition subroutine is executed.

3024  ***  USER INFORMATION MESSAGE 3024, THE BANDWIDTH OF MATRIX **** EXCEEDS
           THE MAXIMUM BANDWIDTH. A MAXIMUM BANDWIDTH OF **** WILL BE USED.

          This message indicates that a matrix has scattered terms way off
          the diagonal (that is, a large bandwidth). Instead of searching all
          combinations of B and C, the search is started at the maximum
          bandwidth.

3025  ***  SYSTEM FATAL MESSAGE 3025, ILLEGAL INDEX IN ACTIVE ROW OR COLUMN
           CALCULATION IN ****.

          Possible machine error. Rerun problem. If error persists, a code
          error exists in the decomposition routine.

3026  ***  SYSTEM FATAL MESSAGE 3026, MATRIX **** EXCEEDS MAXIMUM ALLOWABLE SIZE
           FOR BANDWIDTH PLUS ACTIVE COLUMNS. BMAX = ****, CMAX = ****.

          Sufficient space was not reserved for the generation of the B vs. C
          vector. SDCOMP should be recompiled to increase BMAX and CMAX.

3027  ***  USER INFORMATION MESSAGE 3027, **** DECOMPOSITION OF DATA BLOCK ****
           (N = ****) TIME ESTIMATE IS ******** SECONDS.

          Gives the estimated time required for a decomposition in seconds
          and the type of matrix, that is, complex, real (double or single
          precision), symmetric, or unsymmetric.

3028  ***  USER INFORMATION MESSAGE 3028, B = ****, BBAR = ****, C =  ****, CBAR
           = ***, R = ****.

          Gives the upper bandwidth (B), lower bandwidth (BBAR), number of
          active columns (C), and active rows (CBAR) used in the unsymmetric
          decomposition.

3029  ***  SYSTEM FATAL MESSAGE 3029, PHYSICAL END-OF-FILE ENCOUNTERED ON DATA
           SET **** (FILE ****).

          Since logical end-of-files are used by GINO, a physical end-of-file
          indicates an attempt to read beyond valid data.

3030  ***  USER WARNING MESSAGE 3030, OFP UNABLE TO PROCESS DATA BLOCK. A TABLE
           OF THE DATA BLOCK FOLLOWS.

3031  ***  Same as message 3032.

3032  ***  USER FATAL MESSAGE 3032, UNABLE TO FIND SELECTED SET (****) IN TABLE
           (****) IN SUBROUTINE (****).

          A particular set used in the problem was not included in the data.
          Good examples are loads, initial conditions, or frequency sets.
          Include the required data or change the Case Control Deck to select
          data already in problem. Set zero (0) has a special meaning. A set
          selection was required, but none was made. For example, no METHOD
          was selected for an eigenvalue extraction problem.

          This message can also indicate that a LOAD card has referenced
          another LOAD card, which is not permitted.

3033  ***  USER FATAL MESSAGE 3033, SUBCASE ID **** IS REFERENCED ON ONE OR MORE
           RANDPS CARDS BUT IS NOT A CURRENT SUBCASE ID.

          The RANDPS set selected can only reference subcase identification
          numbers included in the current loop. All subcases in which the
          direct input matrices or transfer functions do not change are run
          together. Either add a subcase with referenced identification
          number, change your RANDPS cards, or change the identification
          numbers on your current subcases.

3034  ***  USER WARNING MESSAGE 3034, ORTHOGONALITY CHECK FAILED, LARGEST TERM =
           **** EPSI = ****.

          The off-diagonal terms of the modal mass matrix are larger than the
          user input criteria on the EIGB or EIGR bulk data card. The
          eigenvectors are not orthogonal to this extent. This non-
          orthogonality is especially important if a modal formulation is
          contemplated.

3035  ***  USER INFORMATION MESSAGE 3035, FOR LOAD ** EPSILON SUB E=*****.

          This is an informative message reflecting the accumulated round-off
          error of the static solution.

3036  ***  SYSTEM FATAL MESSAGE 3036, DATA SET ******** IS REQUIRED AS INPUT BUT
           HAS NOT BEEN GENERATED OR PURGED.

          The above mentioned data set is not accounted for on the OPTP
          checkpoint dictionary. The message indicates a failure of the File
          Name Restart Table. As an interim measure, you can use the ALTER
          feature to execute the proper module to create the needed data set.

3037  ***  SYSTEM FATAL MESSAGE 3037, JOB TERMINATED IN SUBROUTINE ****.

          This message designates the subroutine in which the program
          terminated. It should be preceded by a user message which explains
          the cause of the termination. The module in which the program
          terminated can be found by examining the online time messages.

3038  ***  SYSTEM FATAL MESSAGE 3038, DATA SET *** DOES NOT HAVE MULTIREEL
           CAPABILITY.

          Computer hardware/software does not support multireel files.

3039  ***  SYSTEM FATAL MESSAGE 3039, ENDSYS CANNOT FIND SAVE FILE.

          File cannot be found to save and restore executive tables during
          link switching.

3040  ***  SYSTEM FATAL MESSAGE 3040, ATTEMPT TO WRITE DATA SET ******** (FILE
           ***) WHEN IT IS AN INPUT FILE.

          Input data blocks for a module (100 < NAME < 200) may be read only.

3041  ***  USER WARNING MESSAGE 3041, EXTERNAL GRID POINT *** DOES NOT EXIST OR
           IS NOT A GEOMETRIC GRID POINT. THE BASIC ORIGIN WILL BE USED.

          The reference grid point specified on the PARAM GRDPNT card for
          weight and balance calculations in GPWG cannot be used.

3042  ***  USER WARNING MESSAGE 3042, INCONSISTENT SCALAR MASSES HAVE BEEN USED.
           EPSILON/DELTA = *****.

          GPWG has detected inconsistent scalar masses. Direct masses have
          been used. Skew inertias will result. Examine your scalar masses
          and CONM1 cards.

3043  ***  USER FATAL MESSAGE 3043, UNCONNECTED EXTRA POINT (MODAL
           COORDINATE=***) HAS BEEN DETECTED BY SUBROUTINE ****.

          Extra points must be connected via Direct Matrix Input (or Transfer
          Functions) in modal transient or frequency response.

3044  ***  USER FATAL MESSAGE 3044, A POINT ON NONLINEAR LOAD SET **** NOLIN
           **** IS NOT AN EXTRA POINT. ONLY EXTRA POINTS MAY HAVE NONLINEAR
           LOADS IN A MODAL FORMULATION.

          Modal transient analysis (DISP Rigid Format 12) will support
          nonlinear loads only on extra points. Pick another nonlinear load
          set.

3045  ***  USER WARNING MESSAGE 3045, INSUFFICIENT TIME TO COMPLETE THE
           REMAINING ** SOLUTION(S) IN MODULE ***.

          The time specified on the NASTRAN TIME card has expired in the
          named module. The module will be terminated. NASTRAN will continue
          running until the time on the job card expires. Restart to obtain
          print-out, complete solutions, or rerun problem.

3046  ***  USER FATAL MESSAGE 3046, YOUR SELECTED LOADING CONDITION, INITIAL
           CONDITION, AND NONLINEAR FORCES ARE NULL. A ZERO SOLUTION WILL
           RESULT.

          Transient solution must have one of the above nonzero.

3047  ***  USER FATAL MESSAGE 3047, NO MODES WITHIN RANGE AND LMODES=0. A MODAL
           FORMULATION CANNOT BE MADE.

          The modes used for a modal formulation must be selected by a PARAM
          card. Set LFREQ, HFREQ, or LMODES to request modes.

3048  ***  SYSTEM FATAL MESSAGE 3048, BUFFER CONTROL WORD INCORRECT FOR GINO
           **** OPERATION ON DATA BLOCK ****.

          The buffer control word has been destroyed outside of GINO or an
          attempt to READ a file opened to WRITE or similar error has
          occurred.

3049  ***  SYSTEM FATAL MESSAGE 3049, GINO UNABLE TO POSITION DATA BLOCK
           CORRECTLY DURING OPERATION.

          A block number read does not match the expected block number. The
          file has been repositioned outside the GINO environment or a
          machine or operating system error has occurred.

3050  ***  USER FATAL MESSAGE 3050, INSUFFICIENT TIME REMAINING FOR
           DECOMPOSITION, ****. TIME ESTIMATE IS **** SECONDS.

          The time estimated for a decomposition exceeds the remaining time.
          Increase the time estimate for the run.

3051  ***  USER FATAL MESSAGE 3051, INITIAL CONDITION SET **** WAS SELECTED FOR
           A MODAL TRANSIENT PROBLEM. INITIAL CONDITIONS ARE NOT ALLOWED IN SUCH
           A PROBLEM.

3052  ***  USER WARNING MESSAGE 3052, A RANDOM REQUEST FOR CURVE TYPE - **** -,
           POINT - **** COMPONENT - **** -, SPECIFIES TOO LARGE A COMPONENT ID.
           THE LAST COMPONENT WILL BE USED.

3053  ***  USER WARNING MESSAGE 3053, THE ACCURACY OF EIGENVALUE **** IS IN
           DOUBT. GIVENS-QR FAILED TO CONVERGE IN **** ITERATIONS.

          Each eigenvalue is computed to the precision limits of each machine
          consistent with the maximum number of iterations allowed. A
          programming change would be required to increase the maximum
          iteration parameter.

3054  ***  USER WARNING MESSAGE 3054, THE ACCURACY OF EIGENVECTOR ****
           CORRESPONDING TO THE EIGENVALUE **** IS IN DOUBT.

          The eigenvector failed to converge in the allowable number of
          iterations. Particular attention should be given to the
          off-diagonal terms of the modal mass matrix (MI) to determine if
          this vector is orthogonal to the remaining vectors. These terms
          will be computed and checked if field 9 on the EIGR card contains a
          nonzero value. The message is expected in the case of close or
          multiple eigenvalues, even though the vectors are properly
          computed.

3055  ***  USER FATAL MESSAGE 3055, AN ATTEMPT TO MULTIPLY OR MULTIPLY AND ADD
           NON-CONFORMABLE MATRICES TOGETHER WAS MADE IN SUBROUTINE ********.

          The multiply/add subroutine requires conformable matrices. There
          are two possible cases:

          1. [X] = [A][B] + [C]

          The number of columns of [A] must be equal to the number of rows of
          [B] and the number of columns of [C] must be equal to the number of
          columns of [B] and the number of rows of [C] must be equal to the
          number of rows of [A].

          2. [X] = [A]T[B] + [C]

          The number of rows of [A] must be equal to the number of rows of
          [B]; the number of columns of [C] must be equal to the number of
          columns of [B] and the number of rows of [C] must be equal to the
          number of columns of [A].

3056  ***  USER FATAL MESSAGE 3056, NO MASS MATRIX IS PRESENT BUT MASS DATA IS
           REQUIRED.

          An operation with the mass matrix is required, such as a gravity
          loading condition, but none was created. A typical cause is the
          omission of RHO on the MAT1 card.

3057  ***  USER FATAL MESSAGE 3057, MATRIX **** IS NOT POSITIVE DEFINITE.

          A Cholesky decomposition was attempted on the above matrix, but a
          diagonal term was negative or equal to zero, such that the
          decomposition failed.

3058  ***  USER WARNING MESSAGE 3058, EPSILON IS LARGER THAN **** FOR SUBCASE
           ****.

          The error residual (either l or )

                    T
                 {u}  {P}
            =  -------------
                    T
                 {P}  {u}

          is larger than would be expected for a well conditioned problem.
          Near singularities may exist.

3059  ***  USER FATAL MESSAGE 3059, SET IDENTIFIER **** DOES NOT EXIST. ERROR
           DETECTED IN SUBROUTINE ****.

          When describing displacement matrices, only those set identifiers
          (such as M or G) listed under DMAP module MATGPR (see Section 5.5)
          are legal set descriptors. Choose a set descriptor which is legal
          (and describes the matrices to be operated on).

3060  ***  USER FATAL MESSAGE 3060, READ MODULE FINDS THAT THE INPUT STIFFNESS
           AND/OR MASS MATRIX IS NULL.

3061  ***  USER INFORMATION MESSAGE 3061, THE MEASURE OF NON-PLANARITY IS ****
           FOR ELEMENT NUMBER ********.

          The measure of non-planarity for isoparametric quadrilateral
          membrane elements is the distance from actual grid points to mean
          plane divided by the average length of the diagonals. This message
          is issued only when the absolute value of this measure is greater
          than .01.

3062  ***  SYSTEM FATAL MESSAGE 3062, HMAT MATERIAL ROUTINE CALLED IN A NON-
           HEAT-TRANSFER PROBLEM.

3063  ***  SYSTEM WARNING MESSAGE 3063, INPUT FORCES DATSDRHA BLOCK DOES NOT
           HAVE CORRECT DATA.

3064  ***  SYSTEM WARNING MESSAGE 3064, INCONSISTENT HBDY DATA RECORDS. ********
           ********.

3065  ***  SYSTEM WARNING MESSAGE 3065, THERE IS NO EST DATA FOR HBDY ELEMENT ID
           = ********.

3066  ***  USER WARNING MESSAGE 3066, THERE IS NO TLOAD1 OR TLOAD2 DATA FOR
           LOAD-ID = ********.

3067  ***  USER WARNING MESSAGE 3067, LOAD SET ID = ********** IS NOT PRESENT.

3068  ***  SYSTEM WARNING MESSAGE 3068, UNRECOGNIZED CARD TYPE = **********
           FOUND IN -SLT- DATA BLOCK.

3069  ***  USER WARNING MESSAGE 3069, OUTPUT DATA BLOCK FOR FORCES IS PURGED.

3070  ***  USER WARNING MESSAGE 3070, QGE IS REQUIRED BY THIS MODULE AND IS
           PURGED. NO OUTPUT FILE HAS BEEN CREATED.

3071  ***  SYSTEM WARNING MESSAGE 3071, EXTRA DATA IN RADLST RECORD OF MATPOOL
           DATA BLOCK IGNORED.

3072  ***  USER WARNING MESSAGE 3072, TOO MANY MATRIX VALUES INPUT VIA RADMTX
           BULK DATA FOR COLUMN ********. EXTRA VALUES IGNORED AS MATRIX SIZE IS
           DETERMINED TO BE OF SIZE ******** FROM RADLST COUNT OF ELEMENT ID-S.

3073  ***  USER FATAL MESSAGE 3073, NO -HBDY- ELEMENT SUMMARY DATA IS PRESENT
           FOR ELEMENT ID = ********, WHICH APPEARS ON A -RADLST- BULK DATA
           CARD.

3074  ***  USER FATAL MESSAGE 3074, COLUMN ******** OF THE Y MATRIX IS NULL.

3075  ***  USER FATAL MESSAGE 3075, INTERMEDIATE MATRIX Y IS SINGULAR.

3076  ***  SYSTEM FATAL MESSAGE 3076, GPTT DATA IS NOT IN SORT BY INTERNAL ID.

3077  ***  USER FATAL MESSAGE 3077, THERE IS NO GRID POINT TEMPERATURE DATA OR
           DEFAULT TEMPERATURE DATA FOR SIL POINT ******** AND POSSIBLY OTHER
           POINTS.

3078  ***  USER FATAL MESSAGE 3078, NO GPTT DATA IS PRESENT FOR TEMPERATURE SET
           ********.

3079  ***  USER FATAL MESSAGE 3079, THERE ARE NO -HBDY-ELEMENTS PRESENT.

3080  ***  USER FATAL MESSAGE 3080, ERROR IN QVECT DATA, INTEGER VALUES
           SPECIFIED FOR THERMAL FLUX VECTOR COMPONENTS IN A NON-TRANSIENT
           ANALYSIS. ELEMENT ID = ****.

3081  ***  SYSTEM FATAL MESSAGE 3081, INCONSISTENT USET DATA DETECTED.

3082  ***  USER WARNING MESSAGE 3082, M = **********, N = **********.

          More than one n-set degree-of-freedom is associated with an m-set
          degree-of-freedom. The set relationship to be used is indicated in
          the message.

3083  ***  USER FATAL MESSAGE 3083, UM POSITION = **********, SIL = **********.

          An m-set degree-of-freedom is not expressed in terms of an n-set
          degree-of-freedom.

3084  ***  USER FATAL MESSAGE 3084, THERE IS NO TEMPERATURE DATA FOR SIL NUMBER
           **********.

3085  ***  USER FATAL MESSAGE 3085, THE PF LOAD VECTOR IS EITHER PURGED OR NULL.

3086  ***  USER INFORMATION MESSAGE 3086, ENTERING SSGHT EXIT MODE BY REASON
(1)        NUMBER 1 (NORMAL CONVERGENCE).

3086  ***  USER INFORMATION MESSAGE 3086, ENTERING SSGHT EXIT MODE BY REASON
(2)        NUMBER 2 (MAXIMUM ITERATIONS).

3086  ***  USER INFORMATION MESSAGE 3086, ENTERING SSGHT EXIT MODE BY REASON
(3)        NUMBER 3 (DIVERGING SOLUTION).

3086  ***  USER INFORMATION MESSAGE 3086, ENTERING SSGHT EXIT MODE BY REASON
(4)        NUMBER 4 (INSUFFICIENT TIME).

3086  ***  USER INFORMATION MESSAGE 3086, ENTERING SSGHT EXIT MODE BY REASON
(5)        NUMBER 5 (MAXIMUM CONVERGENCE).

          1. Normal convergence occurs when the solution meets the
          convergence criteria defined by the parameter EPSHT.
          2. Iterations are terminated when the number defined by the
          parameter MAXIT is attained.
          3. Iterations are terminated when the solution diverges.
          4. Iterations are terminated when there is insufficient time to
          complete the next loop.
          5. Iterations are terminated when there is no change to the
          solution vector but the parameter EPSHT criteria was not met.

3087  ***  USER FATAL MESSAGE 3087, TEMPERATURE SET ********** IS NOT PRESENT IN
           GPTT DATA BLOCK.

3088  ***  USER FATAL MESSAGE 3088, ILLEGAL GEOMETRY FOR REVOLUTION ELEMENT
           ****.

3089  ***  USER FATAL MESSAGE 3089, ILLEGAL GEOMETRY FOR TRIANGLE ELEMENT ****.

3090  ***  USER FATAL MESSAGE 3090, ILLEGAL GEOMETRY FOR QUAD ELEMENT ****.

3091  ***  SYSTEM WARNING MESSAGE 3091, A TRAPRG ELEMENT = ************** DOES
           NOT HAVE SIDE 1-2 PARALLEL TO SIDE 3-4.

3092  ***  USER FATAL MESSAGE 3092, TRIARG OR TRAPRG ELEMENT = **************
           POSSESSES ILLEGAL GEOMETRY.

3093  ***  SYSTEM FATAL MESSAGE 3093, ELEMENT = ******** REASON = ******.

          A thermal load (via QVOL card) cannot be computed because:

          1. Fewer than 2 points have been referenced.
          2. Unable to locate SIL value.
          3. Unrecognizable form for element.
          4. Illegal number of points for triangular or quadrilateral
          membranes, plates, or rings.
          5. Illegal number of points for solid hexahedra.

          1 - 3 apply to rods; triangular or quadrilateral membranes, plates,
          or rings; or solid hexahedra.

3094  ***  SYSTEM FATAL MESSAGE 3094, SLT LOAD TYPE ********** IS NOT
           RECOGNIZED.

3095  ***  USER WARNING MESSAGE 3095, ELEMENT TYPE ********** WITH ID =
           *********, AND APPEARING ON EITHER A QVECT, QBDY1, QBDY2, OR QVOL
           LOAD CARD HAS THE SAME ID AS ELEMENT OF ANOTHER TYPE AND IS NOT BEING
           USED FOR LOADING.

3096  ***  USER FATAL MESSAGE 3096, ELEMENT ID = ********** AS REFERENCED ON A
           QVOL, QBDY1, QBDY2, OR QVECT LOAD CARD COULD NOT BE FOUND AMONG
           ACCEPTABLE ELEMENTS FOR THAT LOAD TYPE.

3097  ***  USER FATAL MESSAGE 3097, COLUMN ****** IS SINGULAR. UNSYMMETRIC
(1)        ******** DECOMP ABORTED.

3097  ***  USER FATAL MESSAGE 3097, SYMMETRIC DECOMPOSITION OF DATA BLOCK
(2)        ******** ABORTED BECAUSE THE FOLLOWING COLUMNS ARE SINGULAR --

          When a matrix being read in is singular (null column or, for
          symmetric decomposition, a zero diagonal), the internal column
          number and type of decomposition is identified. The message does
          not appear for special cases such as less than three columns or for
          proportional rows.

3098  ***  USER FATAL MESSAGE 3098, QDMEM2 ELEMENT STIFFNESS ROUTINE DETECTS
           ILLEGAL GEOMETRY FOR ELEMENT ID = **********.

3099  ***  USER FATAL MESSAGE 3099, ELEMENT STIFFNESS COMPUTATION FOR QDMEM2
           ELEMENT ID = ********** IS IMPOSSIBLE DUE TO SINGULARITY IN
           CONSTRAINT EQUATION.

3100  ***  USER WARNING MESSAGE 3100, ELEMENT THERMAL LOAD COMPUTATION FOR
           QDMEM2 ELEMENT ID = ********** FINDS ILLEGAL GEOMETRY THUS NO LOADS
           OUTPUT FOR ELEMENT-ID NOTED.

3101  ***  USER WARNING MESSAGE 3101, SINGULARITY OR BAD GEOMETRY FOR QDMEM2
           ELEMENT ID = ********** STRESS OR FORCES WILL BE INCORRECT.

3102  ***  SYSTEM FATAL MESSAGE 3102, LOGIC ERROR EMA- ****.
(1)

3102  ***  USER WARNING MESSAGE 3102, SUBROUTINE TRHT1C, UNSTABLE TEMP. VALUE OF
(2)        ****************, COMPUTED FOR TIME STEP ***** AT POINT NUMBER ******
           IN THE ANALYSIS STEP.

3103  ***  USER WARNING MESSAGE 3103, EMGCOR OF EMG MODULE FINDS EITHER OF DATA
(1)        BLOCKS **** OR **** ABSENT AND THUS ****, MATRIX WILL NOT BE FORMED.

3103  ***  USER FATAL MESSAGE 3103, SUBROUTINE TRHT1C TERMINATING DUE TO ERROR
(2)        COUNT FOR MESSAGE 3102.

          This occurs for 10 errors detected in the temperature computation.

3104  ***  SYSTEM WARNING MESSAGE 3104, EMGCOR FINDS SET (ASSUMED DATA BLOCK
           *****) MISSING. EMG MODULE COMPUTATIONS LIMITED.

3105  ***  SYSTEM FATAL MESSAGE 3105, EMGPRO FINDS ******** ELEMENTS (ELEMENT
           TYPE ***) UNDEFINED IN EST DATA BLOCK AND/OR ELEMENT ROUTINE.

3106  ***  SYSTEM FATAL MESSAGE 3106, EMGPRO FINDS THAT ELEMENT TYPE *** HAS EST
           ENTRIES TOO LARGE TO HANDLE CURRENTLY.

3107  ***  SYSTEM INFORMATION MESSAGE 3107, EMGOLD CALLED BY EMGPRO TO PROCESS
           ******** ELEMENTS.

3108  ***  SYSTEM FATAL MESSAGE 3108, EMGOUT RECEIVES ILLEGAL FILE TYPE =
           ********.

3109  ***  SYSTEM FATAL MESSAGE 3109, EMGOUT HAS BEEN SENT AN INVALID DICTIONARY
           WORD-2 = ********** FROM ELEMENT ID = **********.

3110  ***  SYSTEM FATAL MESSAGE 3110, EMGOUT HAS BEEN CALLED TO WRITE AN
           INCORRECT NUMBER OF WORDS FOR ELEMENT ID = **********.

3111  ***  SYSTEM FATAL MESSAGE 3111, INVALID NUMBER OF PARTITIONS WERE SENT
           EMGOUT FOR ELEMENT ID = ********** WITH RESPECT TO DATA BLOCK TYPE =
           ***.

3112  ***  USER INFORMATION MESSAGE 3112, ELEMENTS CONGRUENT TO ELEMENT ID =
           ********** WILL BE RE-COMPUTED AS THERE IS INSUFFICIENT CORE AT THIS
           MOMENT TO HOLD DICTIONARY DATA. ADDITIONAL CORE NEEDED = **** WORDS.

3113  ***  SYSTEM INFORMATION MESSAGE 3113, EMGPRO PROCESSING ****** PRECISION
           ELEMENTS (ELEMENT TYPE ***) STARTING WITH ID ********.

3115  ***  USER FATAL MESSAGE 3115, EMGPRO FINDS ******** ELEMENTS (ELEMENT TYPE
           ***) PRESENT IN A HEAT FORMULATION.

          This includes CCONEAX, CTORDRG, CTRAPAX, CTRIAAX, CFLUIDi, CSLOTi,
          CSHEAR, CTWIST, CTRBSC, CTRPLT, CQDPLT, CMASSi, CONMi, CAXIFi,
          CAERO1, CTRIM6, CTRPLT1, and CTRSHL elements.

3116  ***  SYSTEM FATAL MESSAGE 3116, ELEMENT ID ********** SENDS BAD SIL TO
           ROUTINE EMG1B.

3117  ***  USER WARNING MESSAGE 3117, DIFFERENTIAL STIFFNESS CAPABILITY NOT
           DEFINED FOR ELEMENTS (ELEMENT TYPE ****).

3118  ***  USER FATAL MESSAGE 3118, ROD ELEMENT NO. ********** HAS ILLEGAL
           GEOMETRY OR CONNECTIONS.

3119  ***  USER FATAL MESSAGE 3119, INSUFFICIENT CORE TO PROCESS ROD ELEMENTS.

3120  ***  USER WARNING MESSAGE 3120, IMPROPER CONNECTION ON CELAS ELEMENT,
           **********.

3121  ***  SYSTEM WARNING MESSAGE 3121, EMGOLD HAS RECEIVED A CALL FOR ELEMENT
           ID **** (ELEMENT TYPE ELEMENT IGNORED AS THIS ELEMENT TYPE IS NOT
           HANDLED BY EMGOLD.

3122  ***  SYSTEM FATAL MESSAGE 3122, EMGOUT HAS DETERMINED THAT THERE ARE ****
           CONNECTING GRID POINTS FOR ELEMENT ID = ****. THIS IS GREATER THAN
           THE MAXIMUM AS PER /GPTA1/ TABLE FOR THE TYPE OF THIS ELEMENT.
           PROBABLE ERROR IN ELEMENT ROUTINE PROGRAM.

3123  ***  USER FATAL MESSAGE 3123, PARAMETER NUMBER ***** NOT IN DMAP CALL.

3124  ***  USER FATAL MESSAGE 3124, PARAMETER NUMBER ***** IS NOT A VARIABLE.

3125  ***  SYSTEM FATAL MESSAGE 3125, INVALID TABLE NUMBER. **********, IS NO.
           *****, OF *****, PASSED TO PRETABLE.

3128  ***  SYSTEM WARNING MESSAGE 3128, **** **** AND **** **** ARE EQUIVALENT
           LABELS. CONSULT BOTH FOR INTERCHANGEABLE XREF.

3129  ***  USER FATAL MESSAGE 3129, SDR3 CAN ONLY PROCESS 30 ELEMENT TYPES,
           PROBLEM HAS ***.

          The total of 30 different element types includes the sum of the
          different types of structural/scalar elements plus the different
          types of user's DUMMY elements.

3130  ***  SYSTEM FATAL MESSAGE 3130, LOGIC ERROR ****** OCCURRED IN SDCOMP.
           CONTENTS OF /SDCOMX/ FOLLOW --

          Numerous error conditions exist in subroutine SDCOMP. The current
          value in the error message helps the programmer to locate the
          specific area of the code where the error occurred. COMMON block
          SDCOMX is dumped in case DIAG 1 was not on.

3131  ***  USER FATAL MESSAGE 3131, INPUT STIFFNESS AND MASS MATRICES ARE NOT
           COMPATIBLE.

          The matrices must be of the same size in order to properly perform
          matrix operations.

3132  ***  SSGHT RECOVERING FROM SEVERE USER CONVERGENCE CRITERIA.

          A nonlinear heat transfer solution cannot converge because the
          value for EPSHT on a PARAM card is too small. Either change the
          value to one which requires less accuracy or provide for a greater
          number of iterations (MAXIT on another PARAM card) to allow the
          solution to converge.

3133  ***  USER FATAL MESSAGE 3133, LENGTH OF CRIGDR (RIGID ROD) ELEMENT
           ******** IS ZERO.

          The end grid points of the element cannot be coincident.

3134  ***  USER FATAL MESSAGE 3134, CRIGDR (RIGID ROD) ELEMENT ******** IS NOT
           PROPERLY DEFINED.

          The direction defined by the dependent translational degree of
          freedom cannot be perpendicular (or nearly perpendicular) to the
          element.

3135  ***  USER FATAL MESSAGE 3135, UNABLE TO PROCESS SEQGP DATA IN SUBROUTINE
           GP1 DUE TO INSUFFICIENT CORE. ADDITIONAL CORE REQUIRED = **** WORDS.

3136  ***  USER FATAL MESSAGE 3136, MULTIPLE REFERENCES TO GRID (OR SCALAR)
           POINT ID NO. **** ON SEQGP CARDS.

3137  ***  USER FATAL MESSAGE 3137, MULTIPLE REFERENCES TO SEQUENCE ID NO. ****
           ON SEQGP CARDS.

3138  ***  USER FATAL MESSAGE 3138, SEQUENCE ID NO. **** ON SEQGP CARDS IS THE
           SAME AS A GRID (OR SCALAR) POINT ID NO. THAT HAS NOT BEEN
           RESEQUENCED.

3139  ***  USER FATAL MESSAGE 3139, UNABLE TO PROCESS SEQEP DATA IN SUBROUTINE
           DPD1 DUE TO INSUFFICIENT CORE. ADDITIONAL CORE REQUIRED = **** WORDS.

3140  ***  USER FATAL MESSAGE 3140, MULTIPLE REFERENCES TO EXTRA POINT ID NO.
           **** ON SEQEP CARDS.

3141  ***  USER FATAL MESSAGE 3141, MULTIPLE REFERENCES TO SEQUENCE ID NO. ****
           ON SE0EP CARDS.

3142  ***  USER FATAL MESSAGE 3142, SEQUENCE ID NO. **** ON SEQEP CARDS IS THE
           SAME AS AN EXTRA POINT ID NO. THAT HAS NOT BEEN RESEQUENCED.

3143  ***  USER INFORMATION MESSAGE 3143, THE EIGENVALUES AND EIGENVECTORS FOUND
           ON THIS RESTART WILL BE APPENDED TO THE ******** EIGENVALUES AND
           EIGENVECTORS PREVIOUSLY CHECKPOINTED.

          This message is generated when the APPEND feature is being used in
          the case of the Determinant, Inverse Power, and FEER methods of
          real eigenvalue extraction. (See Section 3.4.7).

3144  ***  USER WARNING MESSAGE 3144, EMGPRO FINDS ******** ELEMENTS (ELEMENT
           TYPE ***) PRESENT IN A HEAT FORMULATION AND IS REPLACING THE SAME BY
           ******** ELEMENTS (ELEMENT TYPE ***).

          In a HEAT formulation, element types CQDMEM1 and CQDMEM2 are
          automatically replaced by element type CQDMEM.

3145  ***  USER FATAL MESSAGE 3145, COMPONENT 0 (OR BLANK) SPECIFIED FOR GRID
           POINT ******** ON ******** CARDS.

3146  ***  USER FATAL MESSAGE 3146, NON-ZERO COMPONENT SPECIFIED FOR SCALAR
           POINT ******** ON ******** CARDS.

3147  ***  USER FATAL MESSAGE 3147, ENFORCED DISPLACEMENT ON SPC CARDS SPECIFIED
           MORE THAN ONCE FOR THE SAME COMPONENT. SIL VALUE = ********.

          The use of DIAG 21 in the Executive Control Deck will show the SIL
          (Internal DOF) corresponding to the duplicated component.

3148  ***  USER FATAL MESSAGE 3148, CRIGD3 (GENERAL RIGID) ELEMENT ******** IS
           NOT PROPERLY DEFINED.

          The six reference degrees of freedom selected for the element must
          together represent six independent components of motion.

3149  ***  USER WARNING MESSAGE 3149, USER SPECIFIED NEIGHBORHOOD CENTERED AT
           ORIGIN NOT ALLOWED, CENTER SHIFTED TO THE RIGHT .001.

          Point of interest in the complex plane (ai, wai), closest to which
          the eigenvalues will be computed, was input as (0.0, 0.0) on an
          EIGC bulk data continuation card. The point automatically used is
          (.001, 0.0).

3150  ***  USER WARNING MESSAGE 3150, DESIRED NUMBER OF EIGENVALUES ********
           INVALID. SET = 1.

          Number of accurate roots desired, Ndl, was omitted, input as zero,
          or negative on an EIGC bulk data continuation card. The number
          automatically used is 1.

3151  ***  USER WARNING MESSAGE 3151, DYNAMIC MATRIX IS SINGULAR (OCCURRENCE **)
           IN NEIGHBORHOOD CENTERED AT ******** ********.

          Point of interest in the complex plane (ai, wai), closest to which
          the eigenvalues will be computed, was input too close to an
          eigenvalue on an EIGC bulk data continuation card. The point is
          automatically shifted by adding .02 to both the real and imaginary
          parts. If the dynamic matrix is still singular, the next
          neighborhood, if any, is searched.

3152  ***  USER INFORMATION MESSAGE 3152, SUBROUTINE ALLMAT OUTPUT EIGENVALUE
           **** IS NULL.

          When an eigenvalue output from subroutine ALLMAT is exactly zero,
          the formula for computing the associated theoretical error test
          fails. The magnitude of the eigenvalue is considered to be 10^-10
          for use in that formula.

3153  ***  USER WARNING MESSAGE 3153, ATTEMPT TO NORMALIZE NULL VECTOR IN
           SUBROUTINE CFEER4. NO ACTION TAKEN.

          An eigenvector output from subroutine ALLMAT is a zero vector.

3154  ***  USER WARNING MESSAGE 3154, SIZE OF REDUCED PROBLEM DECREMENTED ONCE
           (NOW ****) DUE TO NULL ERROR ELEMENT.

          If subroutine CFEER4 receives a reduced tridiagonal matrix having
          error element dm+1 exactly (0,0), it is impossible to compute
          meaningful theoretical error estimates for any of the eigenvalues.
          The size of the reduced problem is reduced by one, so that dm
          becomes the new error element.

3155  ***  USER WARNING MESSAGE 3155, REDUCED PROBLEM HAS VANISHED. NO ROOTS
           FOUND.

          If decrementing the size of the reduced problem (see message 3154)
          causes the size to become zero, the program continues to the next
          neighborhood, if any.

3156  ***  USER WARNING MESSAGE 3156, SIZE OF REDUCED PROBLEM RESTORED TO ****
           BECAUSE NEXT ERROR ELEMENT WAS ALSO NULL. ERROR ELEMENT SET = ****
           ****.

          This message follows message 3154. If dm is also exactly zero (in
          addition to dm+1 being exactly zero), then the original reduced
          problem size is restored and dm+1 is set to (, 0), where  = E/100
          and E is the error tolerance on acceptable eigenvalues input on the
          EIGC bulk data card.

3157  ***  USER WARNING MESSAGE 3157, FEER PROCESS MAY HAVE CALCULATED FEWER
           ACCURATE MODES **** THAN REQUESTED IN THE NEIGHBORHOOD OF **** ****.

          The desired number of eigenvalues specified in the EIGC bulk data
          continuation card exceeds the additional number that can be
          calculated by the Complex Tridiagonal Reduction (Complex FEER)
          method in the current neighborhood.

3158  ***  USER WARNING MESSAGE 3158, NO ADDITIONAL MODES CAN BE FOUND BY FEER
           IN THE NEIGHBORHOOD OF **** ****.

          An initial pseudo-random vector cannot be made orthogonal to the
          existing set of orthogonal vectors (which come from Restart and
          from all prior-neighborhood sets of eigensolutions).

3159  ***  USER INFORMATION MESSAGE 3159, ALL SOLUTIONS HAVE BEEN FOUND.

          The FEER method has solved the entire problem. Any additional
          neighborhoods (as specified by the presence of EIGC bulk data
          continuation cards) are ignored.

3160  ***  USER INFORMATION MESSAGE 3160, MINIMUM OPEN CORE NOT USED BY FEER
           ********** WORDS (************ K BYTES).

          This message indicates the amount of open core, in both bytes and
          words, not used by FEER.

3161  ***  USER WARNING MESSAGE 3161, DESIRED NUMBER OF EIGENSOLUTIONS ***** FOR
           NEIGHBORHOOD *** OF *** CENTERED AT ******** ******** EXCEEDS THE
           EXISTING NUMBER *****, ALL EIGENSOLUTIONS WILL BE SOUGHT.

          The desired number of eigenvalues specified on the EIGC bulk data
          continuation card exceeds the size of the eigenmatrix, which is the
          maximum possible number of existing eigenvalues.

3162  ***  USER WARNING MESSAGE 3162, ATTEMPT TO NORMALIZE NULL VECTOR. NO
           ACTION TAKEN.

          The general vector normalization routine (CFNOR1 or CFNOR2) has a
          zero vector input to it.

3163  ***  USER WARNING MESSAGE 3163, ALL **** SOLUTIONS HAVE FAILED ACCURACY
           TEST. NO ROOTS FOUND.

          The number of eigensolutions passing the relative error test is
          zero. The maximum allowable error for the relative error test is
          specified in field 7 of the EIGC bulk data card. A detailed list of
          the computed error bounds could have been obtained by requesting
          DIAG 12 in the Executive Control Deck.

3164  ***  USER INFORMATION MESSAGE 3164, ALL **** SOLUTIONS ARE ACCEPTABLE.

          All the eigensolutions obtained in the reduced problem
          corresponding to the point of interest pass the relative error
          test. The maximum allowable error for the relative error test is
          specified in field 7 of the EIGC bulk data card. A detailed list of
          the computed error estimates could have been obtained by requesting
          DIAG 12 in the Executive Control Deck.

3165  ***  USER INFORMATION MESSAGE 3165, **** SOLUTIONS HAVE BEEN ACCEPTED AND
           **** SOLUTIONS HAVE BEEN REJECTED.

          In each neighborhood defined by a center, some eigensolutions
          passed the relative error test and some did not.

3166  ***  USER INFORMATION MESSAGE 3166, ***** MORE ACCURATE EIGENSOLUTIONS
           THAN THE ***** REQUESTED HAVE BEEN FOUND FOR NEIGHBORHOOD *** OF ***
           CENTERED AT ******** ********. USE DIAG 12 TO DETERMINE ERROR
           ESTIMATES.

          The number of eigensolutions passing the relative error test is
          greater than the number requested on the corresponding EIGC bulk
          data continuation card. The maximum allowable error for the
          relative error test is specified in field 7 of the EIGC bulk data
          card. A detailed list of the computed error estimates could have
          been obtained by requesting DIAG 12 in the Executive Control Deck.

3169  ***  USER WARNING MESSAGE 3169, PRIMARY ID ******** ON A CNGRNT CARD ALSO
           USED AS A SECONDARY ID ON THE SAME CARD. SECONDARY ID IGNORED.

3170  ***  USER FATAL MESSAGE 3170, PRIMARY ID ******** ON A CNGRNT CARD ALSO
           USED AS A SECONDARY ID ON ANOTHER CNGRNT CARD.

3171  ***  USER FATAL MESSAGE 3171, SECONDARY ID ******** SPECIFIED AS CONGRUENT
           TO MORE THAN ONE PRIMARY ID.

3172  ***  USER WARNING MESSAGE 3172, SECONDARY ID ******** REDUNDANTLY
           SPECIFIED ON CNGRNT CARDS. REDUNDANCIES IGNORED.

3173  ***  USER WARNING MESSAGE 3173, NO NON-ZERO MATERIAL COORDINATE SYSTEM IDS
           ENCOUNTERED IN MODULE CURV. {STRESSES/STRAINS/CURVATURES} IN MATERIAL
           COORDINATE SYSTEM NOT COMPUTED.

          Stresses or strains/curvatures are computed in module CURV only if
          non-zero material coordinate system ids are specified.

3174  ***  SYSTEM FATAL MESSAGE 3174, SUBROUTINE CURV* HAS RETURNED WITH ERROR
           CONDITION ***, LOCATION CODE = *** IN SUBROUTINE CURV* FILE NUMBER =
           ***.

          The information supplied by the message should enable a programmer
          to investigate the cause of the error.

3175  ***  USER FATAL MESSAGE 3175, TOTAL NUMBER OF DEGREES OF FREEDOM IN THE
           PROBLEM (****) EXCEEDS 65535.

3176  ***  USER FATAL MESSAGE 3176, BAR ELEMENT NO. **** HAS ILLEGAL GEOMETRY OR
           CONNECTIONS.

3178  ***  USER FATAL MESSAGE 3178, LOAD SET **** NOT FOUND. REQUIRED FOR
           DEFINITION OF COMBINATION LOAD ****.

3179  ***  USER FATAL MESSAGE 3179, DUPLICATE LOAD SET **** FOUND IN DEFINITION
           OF COMBINATION LOAD ****.

3180  ***  USER FATAL MESSAGE 3180, INDEPENDENT COMPONENT SPECIFIED MORE THAN
           ONCE IN AN MPC RELATIONSHIP. SIL VALUE = ****.

3181  ***  USER FATAL MESSAGE 3181, ATTEMPT TO PERFORM CHOLESKY DECOMPOSITION ON
           A NEGATIVE DEFINITE MATRIX IN SUBROUTINE SDCOMP.

3182  ***  USER WARNING MESSAGE 3182, INSUFFICIENT CORE TO PROCESS ALL CNGRNT
           CARDS. ADDITIONAL CORE NEEDED = **** WORDS.

3199  ***  USER WARNING MESSAGE 3199, NON-FATAL MESSAGES MAY HAVE BEEN LOST BY
           ATTEMPTING TO QUEUE MORE THAN ***** MESSAGES.

3300  ***  SYSTEM WARNING MESSAGE 3300, INVALID PARAMETER **** **** SUPPLIED TO
           MODULE DIAGONAL, COLUMN SUBSTITUTED.

3301  ***  USER FATAL MESSAGE 3301, IHEX* ELEMENT NUMBER ******** INSUFFICIENT
           CORE TO COMPUTE ELEMENT MATRIX.

3302  ***  USER FATAL MESSAGE 3302, IHEX* ELEMENT NUMBER ******** ILLEGAL
           GEOMETRY, text (see below).

          The type of geometry error is identified in "text". The
          possibilities are:

          AR EXCEEDED, ALFA EXCEEDED, BETA EXCEEDED
          Either correct the element or increase the allowable value on the
          PIHEX card for this element.

          REVERSED NUMBERING
          The element was numbered in a clockwise fashion rather than
          counter-clockwise as required. This would result in a left-handed
          element coordinate system. Correct the numbering sequence on the
          CIHEXi card for this element.

          COORDINATES OF TWO POINTS ARE THE SAME
          The coordinates of all of the connected points of the element must
          be different.

3303  ***  USER FATAL MESSAGE 3303, STRESSES REQUESTED FOR SET *** WHICH
           CONTAINS NO VALID ELEMENT ID-S.

          The set of elements for which stresses were requested in this
          subcase contains only IDs for nonexistent elements.

3304  ***  USER FATAL MESSAGE 3304, PLOAD3 CARD FROM LOAD SET ********
           REFERENCES MISSING OR NON-ISOPARAMETRIC ELEMENT ********.

3305  ***  USER FATAL MESSAGE 3305, PLOAD3 CARD FROM LOAD SET ******** HAS
           INVALID GRID POINT NUMBERS FOR ELEMENT ********.

          Either the element does not connect the specified grid points, or
          the grid points do not identify the diagonal of a face of the
          element.

3306  ***  USER FATAL MESSAGE 3306, SINGULAR JACOBIAN MATRIX FOR ISOPARAMETRIC
           ELEMENT NUMBER ********.

          The element is severely warped or the outer surface of the element
          is folded through itself. Check the connection card for this
          element and the coordinates of the points it connects.

4000  ***  USER WARNING MESSAGE 4000, ONE SIDE OF ELEMENT ******** CONNECTING
           FOUR POINTS IS NOT APPROXIMATELY PLANAR.

          Check CWEDGE and CHEXAi cards for order of grid point
          identification numbers, or incorrect grid point identification
          numbers.

=PAGE=
6.6  FUNCTIONAL MODULE MESSAGES (4001 THROUGH 5000)

4001  ***  USER FATAL MESSAGE 4001, ELEMENT ******** DOES NOT HAVE CORRECT
           GEOMETRY.

4002  ***  USER FATAL MESSAGE 4002, MODULE SSG1 DETECTS BAD OR REVERSED GEOMETRY
           FOR ELEMENT ID ********.

          Check CWEDGE and CHEXAi cards for order of grid point
          identification numbers or incorrect grid point identification
          numbers. Subtetrahedra must have nonzero volume.

4003  ***  USER FATAL MESSAGE 4003, AN ILLEGAL VALUE OF -NU- HAS BEEN SPECIFIED
           UNDER MATERIAL ******** ID FOR ELEMENT ID ********.

          Solid WEDGE and HEXAi elements must not have Poisson's ratio equal
          to 0.5.

4004  ***  USER FATAL MESSAGE 4004, MODULE SMA1 DETECTS BAD OR REVERSED GEOMETRY
           FOR ELEMENT ID ********.

          Check CWEDGE and CHEXAi cards for order of grid point
          identification numbers, or incorrect grid point identification
          numbers. Subtetrahedra must have nonzero volume.

4005  ***  USER FATAL MESSAGE 4005, AN ILLEGAL VALUE OF  -NU- HAS BEEN SPECIFIED
           UNDER MATERIAL ******** ID FOR ELEMENT ID ********.

          Solid TETRA elements must not have Poisson's ratio equal to 0.5.

4010  ***  USER FATAL MESSAGE 4010, TEMPP3 BULK DATA CARD WITH SETID = ********
           AND ELEMENT ID = ******** DOES NOT HAVE ASCENDING VALUES SPECIFIED
           FOR Z.

4011  ***  USER FATAL MESSAGE 4011, ELEMENT TEMPERATURE SET ******** CONTAINS
           MULTIPLE TEMPERATURE DATA SPECIFIED FOR ELEMENT ID ********.

          Temperature for element is specified on more than one bulk data
          card.

4012  ***  USER FATAL MESSAGE 4012, THERE IS NO ELEMENT, GRID POINT, OR DEFAULT
           TEMPERATURE DATA FOR TEMPERATURE SET ******** WITH RESPECT TO ELEMENT
           ********.

4013  ***  USER FATAL MESSAGE 4013, PROBLEM LIMITATION OF 66 TEMPERATURE SETS
           HAS BEEN EXCEEDED.

4014  ***  SYSTEM FATAL MESSAGE 4014, ROUTINE EDTL DETECTS BAD DATA ON
           TEMPERATURE DATA BLOCK FOR SET ID = ********.

          Data block GPTT should be investigated.

4015  ***  SYSTEM WARNING MESSAGE 4015, ELEMENT THERMAL AND DEFORMATION LOADING
           NOT COMPUTED FOR ILLEGAL ELEMENT TYPE ******** IN MODULE SSG1.

          Only certain elements have algorithms for enforced deformation or
          thermal loading. This element type will not produce a load. Check
          DEFORM and TEMPP1, TEMPP2, TEMPP3, and TEMPRB bulk data cards.

4016  ***  USER FATAL MESSAGE 4016, THERE IS NO TEMPERATURE DATA FOR ELEMENT
           ******** IN SET ********.

4017  ***  USER FATAL MESSAGE 4017, THERE IS NO TEMPERATURE DATA FOR ELEMENT
           ******** IN SET ********.

4018  ***  USER FATAL MESSAGE 4018, A SINGULAR MATERIAL MATRIX -D- FOR ELEMENT
           ******** HAS BEEN DETECTED BY ROUTINE SSGKHI WHILE TRYING TO COMPUTE
           THERMAL LOADS WITH TEMPP2 CARD DATA.

          The element bending load to curvature relation is at fault and
          cannot be inverted.

4019  ***  SYSTEM FATAL MESSAGE 4019, SDR2E DETECTS INVALID TEMPERATURE DATA FOR
           ********.

          Data block GPTT should be investigated.

4020  ***  SYSTEM FATAL MESSAGE 4020, TA1A HAS PICKED UP TEMPERATURE SET
           ******** AND NOT THE REQUESTED SET ********.

          The requested temperature set ID for temperature-dependent material
          properties cannot be found in data block GPTT.

4021  ***  SYSTEM FATAL MESSAGE 4021, TA1B HAS PICKED UP TEMPERATURE SET
           ******** AND NOT THE REQUESTED SET ********.

          The requested temperature set ID for temperature-dependent material
          properties cannot be found in data block GPTT.

4022  ***  USER FATAL MESSAGE 4022, TA1B FINDS NO ELEMENT, GRIDPOINT, OR DEFAULT
           TEMPERATURE DATA FOR ELEMENT ID = ********.

4023  ***  USER FATAL MESSAGE 4023, TA1A FINDS NO ELEMENT, GRIDPOINT, OR DEFAULT
           TEMPERATURE DATA FOR ELEMENT ID = ********.

4024  ***  USER FATAL MESSAGE 4024, NO CYJOIN CARDS WERE SUPPLIED.

4025  ***  USER FATAL MESSAGE 4025, NO SIDE 1 DATA FOUND.

4026  ***  USER FATAL MESSAGE 4026, TOO MANY SIDE 1 CARDS.

4027  ***  USER FATAL MESSAGE 4027, NUMBER OF ENTRIES IN SIDE 1 NOT EQUAL TO
           NUMBER IN SIDE 2.

4028  ***  USER FATAL MESSAGE 4028, THE CODE FOR GRID POINT, ********** DOES NOT
           MATCH THE CODE FOR GRID POINT **********.

          A GRID point on SIDE 1 must be connected to a GRID point on SIDE 2
          and a SCALAR point on SIDE 1 must be connected to a SCALAR point on
          SIDE 2.

4029  ***  USER FATAL MESSAGE 4029, GRID POINT, ********** APPEARS IN BOTH SIDE
           LISTS.

4030  ***  USER WARNING MESSAGE 4030, COMPONENT *** OF GRID POINTS, **********
           AND ********** CANNOT BE CONNECTED.

4031  ***  USER FATAL MESSAGE 4031, INSUFFICIENT CORE = **** TO READ DATA ON
           AXIF CARD.

4032  ***  USER WARNING MESSAGE 4032, NO COMPONENTS OF GRID POINTS, **********
           AND ********** WERE CONNECTED.

4033  ***  USER FATAL MESSAGE 4033, COORDINATE SYSTEM ID = **** AS SPECIFIED ON
           AXIF CARD IS NOT PRESENT AMONG ANY OF CORD1C, CORD2C, OR CORD2S CARD
           TYPES.

          Cylindrical type assumed for continuing data check.

4034  ***  USER FATAL MESSAGE 4034, INSUFFICIENT CORE TO HOLD GRIDB CARD IMAGES.
           ADDITIONAL CORE NEEDED = **** WORDS.

4035  ***  USER FATAL MESSAGE 4035, THE FLUID DENSITY HAS NOT BEEN SPECIFIED ON
           A BDYLIST CARD AND THERE IS NO DEFAULT FLUID DENSITY SPECIFIED ON THE
           AXIF CARD.

4036  ***  USER FATAL MESSAGE 4036, INSUFFICIENT CORE TO BUILD BOUNDARY LIST
           TABLE.

4037  ***  USER FATAL MESSAGE 4037, GRID POINT ********** IS LISTED MORE THAN
           ONCE.

4038  ***  USER FATAL MESSAGE 4038, RINGFL CARD HAS ID = **** WHICH HAS BEEN
           USED.

          An identification number of a RINGFL card is not unique.

4039  ***  USER FATAL MESSAGE 4039, NO COORDINATE SYSTEM DEFINED FOR GRID POINT
           **********.

4040  ***  USER FATAL MESSAGE 4040, ID = **** APPEARS ON A BDYLIST CARD, BUT NO
           RINGFL CARD IS PRESENT WITH THE SAME ID.

4041  ***  USER FATAL MESSAGE 4041, ID = **** IS OUT OF PERMISSIBLE RANGE OF 1
           TO 499999.

          The identification number of a RINGFL card is too large to be
          processed.

4042  ***  USER FATAL MESSAGE 4042, COORDINATE SYSTEM IS CYLINDRICAL BUT RINGFL
           CARD ID = **** HAS A NONZERO X2 VALUE.

          The azimuthal angle of a RINGFL point must be zero.

4043  ***  USER FATAL MESSAGE 4043, COORDINATE SYSTEM IS SPHERICAL BUT RINGFL
           CARD ID = **** HAS A NONZERO X3 VALUE.

          The azimuthal angle of a RINGFL point must be zero.

4044  ***  USER FATAL MESSAGE 4044, RINGFL CARD ID = **** HAS SPECIFIED A ZERO
           RADIAL LOCATION.

4045  ***  USER FATAL MESSAGE 4045, THE BOUNDARY LIST ENTRY FOR ID = **** HAS A
           ZERO CROSS-SECTIONAL LENGTH.

          A hydroelastic boundary cannot be defined between two RINGFL points
          having the same location. Check BDYLIST and RINGFL.

4047  ***  USER FATAL MESSAGE 4047, INSUFFICIENT CORE TO HOLD RINGFL IMAGES.
           ADDITIONAL CORE NEEDED = **** WORDS.

4048  ***  USER FATAL MESSAGE 4048, THE FLUID DENSITY HAS NOT BEEN SPECIFIED ON
           A FSLIST CARD AND THERE IS NO DEFAULT FLUID DENSITY SPECIFIED ON THE
           AXIF CARD.

4049  ***  USER FATAL MESSAGE 4049, INSUFFICIENT CORE TO BUILD FREE SURFACE LIST
           TABLE. ADDITIONAL CORE NEEDED = **** WORDS.

4050  ***  USER FATAL MESSAGE 4050, FSLIST CARD HAS INSUFFICIENT IDF DATA, OR
           FSLIST DATA MISSING.

          A referenced RINGFL point does not exist or the FSLIST card is in
          error. At least two points must be defined.

4051  ***  USER FATAL MESSAGE 4051, AN MPC CARD HAS A SET ID SPECIFIED = 102.
           SET 102 IS ILLEGAL WHEN FLUID DATA IS PRESENT.

          This set identification number is reserved for internal use in
          hydroelastic problems.

4052  ***  USER FATAL MESSAGE 4052, IDF = **** ON A FREEPT CARD DOES NOT APPEAR
           ON ANY FSLIST CARD.

          A referenced RINFGL point must also appear on a FSLIST card.

4053  ***  USER FATAL MESSAGE 4053, INSUFFICIENT CORE TO PERFORM OPERATIONS
           REQUIRED AS A RESULT OF FREEPT OR PRESPT DATA CARDS. ADDITIONAL CORE
           NEEDED = **** WORDS.

4054  ***  USER WARNING MESSAGE 4054, STRESSES OR FORCES REQUESTED FOR SET(S)
           WHICH CONTAIN NO VALID ELEMENTS.

          Stress or force output requests are not valid for fluid elements.

4055  ***  USER FATAL MESSAGE 4055, SET ID = 102 MAY NOT BE USED FOR SPC CARDS
           WHEN USING THE HYDROELASTIC-FLUID ELEMENTS.

          This set identification number is reserved for internal use in
          hydroelastic problems.

4056  ***  USER FATAL MESSAGE 4056, RECORD ID **** **** IS OUT OF SYNC ON DATA
           BLOCK NUMBER **** AN IFP4 SYSTEM ERROR.

          The record identification numbers are the values of LOCATE record
          ID. The data block numbers are the GINO file numbers. Error implies
          that IFP4 is possibly operating on the wrong data block. This
          system error should not occur. Message comes from IFP4B.

4057  ***  USER FATAL MESSAGE 4057, GRIDB CARD WITH ID = **** HAS A REFERENCE
           IDF **** WHICH DOES NOT APPEAR IN A BOUNDARY LIST.

4058  ***  USER FATAL MESSAGE 4058, THE FLUID DENSITY HAS NOT BEEN SPECIFIED ON
           A CFLUID CARD WITH ID = *** AND THERE IS NO DEFAULT ON THE AXIF CARD.

4059  ***  USER FATAL MESSAGE 4059, THE FLUID BULK MODULUS HAS NOT BEEN
           SPECIFIED ON A CFLUID CARD WITH ID = **** AND THERE IS NO DEFAULT ON
           THE AXIF CARD.

4060  ***  SYSTEM FATAL MESSAGE 4060, COORDINATE SYSTEM = **** CANNOT BE FOUND
           IN CSTM DATA.

          Data blocks MATPOOL and/or CSTM have been changed illegally.

4061  ***  SYSTEM FATAL MESSAGE 4061, CONNECTED FLUID POINT ID = **** IS MISSING
           BGPDT DATA.

          Data blocks MATPOOL and/or BGPDT have been changed illegally.

4062  ***  USER FATAL MESSAGE 4062, DMIG BULK DATA CARD SPECIFIES DATA BLOCK
           **** WHICH ALSO APPEARS ON A DMIAX CARD.

          A direct input matrix may not be specified by both types of bulk
          data cards.

4063  ***  USER FATAL MESSAGE 4063, ILLEGAL VALUE **** FOR PARAMETER CTYPE.

4064  ***  USER FATAL MESSAGE 4064, ILLEGAL VALUES ******** FOR PARAMETERS
           NSEGS, KMAX.

4065  ***  USER FATAL MESSAGE 4065, ILLEGAL VALUE ******** FOR PARAMETER NLOAD.

4066  ***  USER FATAL MESSAGE 4066, SECOND OUTPUT DATA BLOCK MUST NOT BE PURGED.

          The transformation matrix between physical and symmetric components
          does not exist. Ensure that the Case Control subcases are specified
          correctly and that the component loads are properly ordered.

4067  ***  USER FATAL MESSAGE 4067, VIN HAS ******** COLS, GCYC HAS ********
           ROWS.

          Follows message 4064 or 4065 indicating illegal values for NSEGS,
          KMAX, or NLOAD. VIN is the first input data block.

4081  ***  USER FATAL MESSAGE 4081, AXSLOT DATA CARD IS NOT PRESENT OR IS
           INCORRECT.

          Acoustic analysis data is present and this data card is necessary.

4082  ***  USER FATAL MESSAGE 4082, INSUFFICIENT CORE TO HOLD ALL GRIDS CARD
           IMAGES.

          Executive Module IFP5 must hold this data in core. Increase core
          size or decrease amount of data.

4083  ***  USER FATAL MESSAGE 4083, INSUFFICIENT CORE TO HOLD ALL GRIDF CARD
           IMAGES.

          Executive Module IFP5 must hold this data in core. Increase core
          size or decrease amount of data.

4084  ***  USER FATAL MESSAGE 4084, INSUFFICIENT CORE TO HOLD ALL GRIDF CARD
           IMAGES BEING CREATED INTERNALLY DUE TO GRIDS CARDS SPECIFYING AN IDF.

          Executive Module IFP5 is creating GRIDF cards from GRIDS cards.
          Increase core size.

4085  ***  USER FATAL MESSAGE 4085, INSUFFICIENT CORE TO CONSTRUCT ENTIRE
           BOUNDARY TABLE FOR SLBDY DATA CARDS.

          Executive Module IFP5 requires five words of core for each entry in
          the SLBDY cards.

4086  ***  USER FATAL MESSAGE 4086, CELAS2 DATA CARD HAS ID = *** WHICH IS
           GREATER THAN 10000000, AND 10000000 IS THE LIMIT FOR CELAS2 ID WITH
           ACOUSTIC ANALYSIS DATA CARDS PRESENT.

          Executive Module IFP5 is generating CELAS2 images and a possible
          conflict of ID numbers exists.

4087  ***  USER FATAL MESSAGE 4087, SLBDY ID = *** DOES NOT APPEAR ON ANY GRIDS
           DATA CARD.

          The SLBDY data card has a point listed which does not exist in the
          data.

4088  ***  USER FATAL MESSAGE 4088, ONE OR MORE OF THE FOLLOWING ID-S NOT EQUAL
           TO -1 HAVE INCORRECT OR NO GEOMETRY DATA. ID = ***, ID = ***, ID =
           ***.

          The listed GRIDS points may have a bad radius or a slot width
          greater than geometrically possible.

4089  ***  USER FATAL MESSAGE 4089, RHO AS SPECIFIED ON SLBDY OR AXSLOT DATA
           CARD IS 0.0 FOR ID = ***.

          A value of density is required to formulate the slot boundary
          matrix tea.

4090  ***  USER FATAL MESSAGE 4090, ONE OF THE FOLLOWING NON-ZERO IDENTIFICATION
           NUMBERS APPEARS ON SOME COMBINATION GRID, GRIDS, OR GRIDF BULK DATA
           CARDS. ID = ***, ID = ***, ID = ***.

          All GRID, SPOINT, EPOINT, GRIDS, and GRIDF data cards should have
          unique identification numbers.

4091  ***  USER FATAL MESSAGE 4091, BAD GEOMETRY OR ZERO COEFFICIENT FOR SLOT
           ELEMENT NUMBER ***.

          The listed CSLOT3 or CSLOT4 element has its connected points
          defining zero area or its density equal to zero.

4100  ***  SYSTEM FATAL MESSAGE 4100, OUTPUT3 UNABLE TO OPEN DATA BLOCK
           ********.

4101  ***  SYSTEM FATAL MESSAGE 4101, OUTPUT3 UNABLE TO FIND NAME FOR DATA BLOCK
           ********.

4102  ***  SYSTEM FATAL MESSAGE 4102, OUTPUT3 EOF.

4103  ***  USER INFORMATION MESSAGE 4103, OUTPUT3 HAS PUNCHED MATRIX DATA BLOCK
           ******** ONTO DMI CARDS.

4104  ***  USER FATAL MESSAGE 4104, ATTEMPT TO PUNCH MORE THAN 99999 DMI CARDS
           FOR A SINGLE MATRIX.

4105  ***  USER INFORMATION MESSAGE 4105, DATA BLOCK ******** RETRIEVED FROM
           {USER/FORTRAN} TAPE **** NAME OF DATA BLOCK WHEN PLACED ON
           {USER/FORTRAN} TAPE WAS ********.

4106  ***  SYSTEM FATAL MESSAGE 4106, MODULE INPUTT1 - SHORT REC.

4107  ***  SYSTEM FATAL MESSAGE 4107, SUBROUTINE INPTT1 UNABLE TO OPEN NASTRAN
           FILE ****.

4108  ***  SYSTEM FATAL MESSAGE 4108, SUBROUTINE {INPTT1/INPTT2} UNABLE TO OPEN
           OUTPUT DATA BLOCK ****.

4109  ***  USER FATAL MESSAGE 4109, TAPE **** CANNOT BE SWITCHED. FILE **** IS
           NOT A TAPE.

4111  ***  USER FATAL MESSAGE 4111, MODULE INPUTT1 IS UNABLE TO SKIP FORWARD
           ********** DATA BLOCKS ON PERMANENT NASTRAN FILE **** NUMBER OF DATA
           BLOCKS SKIPPED = *****.

4112  ***  USER FATAL MESSAGE 4112, MODULE INPUTT1 - ILLEGAL VALUE FOR SECOND
           PARAMETER = *******************.

4113  ***  USER FATAL MESSAGE 4113, MODULE {INPUT1/INPUTT2} - ILLEGAL VALUE FOR
           FIRST PARAMETER = *******************.

4114  ***  USER INFORMATION MESSAGE 4114, DATA BLOCK ******** WRITTEN ON
           {NASTRAN FILE/FORTRAN UNIT} ****, TRLR = ************.

4115  ***  SYSTEM FATAL MESSAGE 4115, MODULE {OUTPUT1/OUTPUT2} - SHORT REC.

4117  ***  SYSTEM FATAL MESSAGE 4117, SUBROUTINE OUTPT1 UNABLE TO OPEN NASTRAN
           FILE ****.

4118  ***  USER FATAL MESSAGE 4118, ***** MODULE OUTPUT1 IS UNABLE TO SKIP
           FORWARD ********** DATA BLOCKS ON PERMANENT NASTRAN FILE ****. ****
           NUMBER OF DATA BLOCKS SKIPPED = *****.

4119  ***  USER FATAL MESSAGE 4119, MODULE OUTPUT1 - ILLEGAL VALUE FOR SECOND
           PARAMETER = *******************.

4120  ***  USER FATAL MESSAGE 4120, MODULE {OUTPUT1/OUTPUT2} - ILLEGAL VALUE FOR
           FIRST PARAMETER = *******************.

4121  ***  USER FATAL MESSAGE 4121, ONLY ONE (1) AXIF CARD ALLOWED IN BULK DATA.

4122  ***  USER FATAL MESSAGE 4122, AXIF CARD REQUIRED.

4123  ***  USER FATAL MESSAGE 4123, ONLY ONE (1) FLSYM CARD ALLOWED IN BULK
           DATA.

4124  ***  USER WARNING MESSAGE 4124, THE SPCADD OR MPCADD UNION CONSISTS OF A
           SINGLE SET.

4125  ***  USER FATAL MESSAGE 4125, MAXIMUM ALLOWABLE HARMONIC ID IS 99. DATA
           CONTAINS MAXIMUM = ****.

4126  ***  USER FATAL MESSAGE 4126, BAD DATA OR FORMAT OR NONUNIQUE NAME, DMIAX
           ****.

4127  ***  USER FATAL MESSAGE 4127, USER TAPE **** NOT SET UP.

4128  ***  USER FATAL MESSAGE 4128, MODULE OUTPUT1 - END-OF-FILE ENCOUNTERED
           WHILE ATTEMPTING TO READ TAPE ID CODE ON USER TAPE ****.

4129  ***  USER FATAL MESSAGE 4129, MODULE OUTPUT1 - END-OF-RECORD ENCOUNTERED
           WHILE ATTEMPTING TO READ TYPE ID CODE ON USER TAPE ****.

4130  ***  USER FATAL MESSAGE 4130, MODULE {OUTPUT1/OUTPUT2} - ILLEGAL TAPE CODE
           HEADER = *******************.

4131  ***  USER WARNING MESSAGE 4131, {USER/FORTRAN} TAPE ID CODE  - ******** -
           DOES NOT MATCH THIRD {OUTPUT1/OUTPUT2} DMAP PARAMETER - ********.

4132  ***  USER FATAL MESSAGE 4132, MODULE INPUTT1 - END-OF-FILE ENCOUNTERED
           WHILE ATTEMPTING TO READ TAPE ID CODE ON USER TAPE ****.

4133  ***  USER FATAL MESSAGE 4133, MODULE INPUTT1 - END-OF-RECORD ENCOUNTERED
           WHILE ATTEMPTING TO READ TAPE ID CODE ON USER TAPE ****.

4134  ***  USER FATAL MESSAGE 4134, MODULE {INPUTT1/INPUTT2} ILLEGAL TAPE CODE
           HEADER = *******************.

4135  ***  USER WARNING MESSAGE 4135, USER TAPE ID CODE - ******** DOES NOT
           MATCH THIRD {INPUTT1/INPUTT2} DMAP PARAMETER - ******** -.

4136  ***  USER FATAL MESSAGE 4136, USER TAPE ID CODE - ******** - DOES NOT
           MATCH THIRD {INPUTT1/INPUTT2} DMAP PARAMETER - ******** -.

4137  ***  USER WARNING MESSAGE 4137, ALL OUTPUT DATA BLOCKS FOR
           {INPUTT1/INPUTT2} ARE PURGED.

4138  ***  USER WARNING MESSAGE 4138, DATA BLOCK ******** (DATA BLOCK COUNT =
           ****) HAS PREVIOUSLY BEEN RETRIEVED FROM {USER/FORTRAN} TAPE **** AND
           WILL BE IGNORED.

4139  ***  USER INFORMATION MESSAGE 4139, DATA BLOCK ******** RETRIEVED FROM
           {USER/FORTRAN} TAPE **** (DATA BLOCK COUNT = *****).

4140  ***  USER WARNING MESSAGE 4140, SECONDARY VERSION OF DATA BLOCK HAS
           REPLACED EARLIER ONE.

4141  ***  USER WARNING MESSAGE 4141, ONE OR MORE DATA BLOCKS NOT FOUND ON
           {USER/NASTRAN} TAPE.

4142  ***  USER FATAL MESSAGE 4142, ONE OR MORE DATA BLOCKS NOT FOUND ON USER
           TAPE.

4143  ***  USER INFORMATION MESSAGE 4143, THIS IS AN UNMODIFIED RESTART.

4144  ***  USER INFORMATION MESSAGE 4144, THIS IS A MODIFIED RESTART.

4145  ***  USER INFORMATION MESSAGE 4145, THIS IS A MODIFIED RESTART INVOLVING
           RIGID FORMAT SWITCH.

4146  ***  SYSTEM FATAL MESSAGE 4146, LOGIC ERROR IN SUBROUTINE XGPI WHILE
           PROCESSING DATA CHANGES FOR MODIFIED RESTART.

4147  ***  USER INFORMATION MESSAGE 4147, NOTE THAT ADDITIONAL DMAP INSTRUCTIONS
           (NOT INDICATED BY AN * IN THE DMAP SOURCE LISTING) NEED TO BE FLAGGED
           FOR EXECUTION IN ORDER TO GENERATE CERTAIN REQUIRED DATA BLOCKS. SUCH
           INSTRUCTIONS AND THE ASSOCIATED DATA BLOCKS ARE IDENTIFIED BELOW.

4148  ***  USER INFORMATION MESSAGE 4148, NOTE THAT ADDITIONAL DMAP INSTRUCTIONS
           (NOT INDICATED BY AN * IN THE DMAP SOURCE LISTING) NEED TO BE FLAGGED
           FOR EXECUTION SINCE THIS UNMODIFIED RESTART INVOLVES DMAP LOOPING AND
           THE REENTRY POINT IS WITHIN A DMAP LOOP. SUCH INSTRUCTIONS ARE
           IDENTIFIED BELOW. THE EXECUTION WILL, HOWEVER, RESUME AT THE LAST
           REENTRY POINT (DMAP INSTRUCTION NO. ****).

4149  ***  USER FATAL MESSAGE 4149, ATTEMPT TO ADD MATRICES OF UNEQUAL ORDER IN
           MODULE {ADD/ADD5}.

5000  ***  USER FATAL MESSAGE 5000, NEG. OR ZERO RADIUS DETECTED FOR CFLUID2
           ELEMENT. ELEMENT NO. ****.

=PAGE=
6.7  FUNCTIONAL MODULE MESSAGES (5001 THROUGH 6000)

5001  ***  USER FATAL MESSAGE 5001, NEG. OR ZERO RADIUS DETECTED FOR CFLUID3 OR
           CFLUID4 ELEMENT. ELEMENT NO. ****.

5002  ***  USER FATAL MESSAGE 5002, INTERIOR ANGLE GREATER THAN OR EQUAL TO 180
           DEGREES. CFLUID4 ELEMENT NO. ****.

5003  ***  USER FATAL MESSAGE 5003, ZERO XZ VALUE ON RINGFL CARD WITH SPHERICAL
           COORDINATES. FLUID POINT ID = ****.

5004  ***  USER FATAL MESSAGE 5004, FLUID POINT ID ON CFLUIDI OR RINGFL CARD AT
           99999.

5011  ***  USER FATAL MESSAGE 5011, FIRST PARAMETER ***** NE TRAILER RECORD
           PARAMETER *****.

5012  ***  USER FATAL MESSAGE 5012, ENTRY ***** OF SIL TABLE INCOMPATIBLE WITH
           NEXT ENTRY.

=PAGE=
6.8  FUNCTIONAL MODULE MESSAGES (6001 THROUGH 7000)

6001  ***  USER FATAL MESSAGE 6001, SUBSTRUCTURE DATA IS REQUIRED WITH THIS
           APPROACH.

          The program expects a SUBSTRUCTURE card following the CEND card if
          APP DISP, SUBS was used.

6002  ***  USER WARNING MESSAGE 6002, INCORRECT PHASE DATA.

          The second word on the substructure command should be PHASEi, i =
          1, 2, 3. The default is 2.

6003  ***  USER FATAL MESSAGE 6003, ILLEGAL COMMAND OR OPTION DEFINED ON
           PREVIOUS CARD.

          The program does not recognize the previous card. If any
          "subcommand" cards follow this error, they may produce this message
          until a legitimate command card is encountered.

6004  ***  USER WARNING MESSAGE 6004, NO PREFIX DEFINED AFTER EQUIVALENCE
           COMMAND.

          A prefix must be defined to identify the equivalent lower level
          basic substructures. To equivalence a basic substructure also
          requires that the prefix be defined.

6005  ***  USER FATAL MESSAGE 6005, ILLEGAL OR MISSING INPUT DATA GIVEN FOR
           PREVIOUS COMMAND.

          Either the basic command data is insufficient or mandatory
          additional subcommands are missing.

6006  ***  USER FATAL MESSAGE 6006, DMAP ALTERS INTERFERE WITH SUBSTRUCTURE
           ALTERS.

          DMAP instruction numbers on user ALTER data cards overlap or
          conflict with sections automatically modified. Use DIAG 23 to print
          DMAP ALTER package or see Sections 5 and 3. Note that card APP
          DISPLACEMENT, SUBS, 1 suppresses automatic generation of DMAP
          instructions.

6007  ***  SYSTEM FATAL MESSAGE 6007, IMPROPER FILE SETUP FOR ****.

          An external I/O operation has been defined but the file is missing
          or the card is improper. Occurs due to previously listed errors or
          from an illegal format in the NPTP or CASECC file.

6008  ***  USER FATAL MESSAGE 6008, ILLEGAL INPUT ON THE PREVIOUS COMMAND.
           MISSING FILE NAME FOR I/O OPERATION.

          The EXIO commands, SOFIN, SOFOUT, DUMP, etc. require a file name.

6009  ***  SYSTEM FATAL MESSAGE 6009, UNRECOVERABLE ERROR CONDITIONS IN
           SUBROUTINE ASDMAP.

          An unusual combination of previously listed errors or program
          errors will cause this condition.

6010  ***  SYSTEM FATAL MESSAGE 6010, ILLEGAL VARIABLE TO BE SET IN DMAP
           STATEMENT, (N).

          The system has encountered an illegal type of word to be inserted
          in a DMAP sequence. For example, a floating point number is used
          instead of an integer on an input card.

6011  ***  USER FATAL MESSAGE 6011, MISSING PASSWORD OR SOF DATA.

          The SOF and PASSWORD cards are mandatory. At least one SOF file,
          SOF(1), must be defined.

6012  ***  SYSTEM FATAL MESSAGE 6012, FILE=**** IS PURGED OR NULL AND IS
           REQUIRED IN PHASE1 SUBSTRUCTURE ANALYSIS.

          The error will occur due to user DMAP ALTERs or if no grid or
          scalar points are defined.

6013  ***  USER FATAL MESSAGE 6013, ILLEGAL TYPE OF POINT DEFINED FOR
           SUBSTRUCTURE ANALYSIS. POINT NUMBER=********.

          An illegal type of grid point (that is, aero or axisymmetric) has
          been encountered.

6014  ***  USER FATAL MESSAGE 6014, INSUFFICIENT CORE TO LOAD TABLES IN MODULE
           SUBPH1, CORE = ********.

          At least three words of core per grid point are required.

6015  ***  USER FATAL MESSAGE 6015, TOO MANY CHARACTERS TO BE INSERTED IN A DMAP
           LINE. N=****.

          A BCD word has been defined with too many characters to fit the
          space in the DMAP. (Usual limit = 8). Message could also occur if
          any of the subroutines ASCMxx has an error.

6016  ***  USER FATAL MESSAGE 6016, TOO MANY DIGITS TO BE INSERTED IN DMAP
           VALUE=***.

          An integer is limited to eight digits.

6017  ***  USER FATAL MESSAGE 6017, MISSING ENDSUBS CARD.

6022  ***  USER FATAL MESSAGE 6022, SUBSTRUCTURE ***, GRID POINT ***, COMPONENT
           ***, REFERENCED ON CARD DOES NOT EXIST IN SOLUTION STRUCTURE ***.

6023  ***  USER WARNING MESSAGE 6023, REQUESTED PLOT SET NO. *******************
           HAS NOT BEEN DEFINED.

          The requested set must be defined in the plot control deck in Case
          Control.

6101  ***  SYSTEM FATAL MESSAGE 6101, REQUESTED SOF ITEM DOES NOT EXIST. ITEM
           ***, SUBSTRUCTURE ***.

          Either the item has never been created or it only pseudo exists in
          a prior dry run.

6102  ***  SYSTEM FATAL MESSAGE 6102, REQUESTED SUBSTRUCTURE DOES NOT EXIST.
           ITEM ***, SUBSTRUCTURE ***.

          You have probably misspelled the substructure name or is using the
          wrong SOF.

6103  ***  SYSTEM FATAL MESSAGE 6103, REQUESTED SOF ITEM HAS INVALID NAME. ITEM
           ***, SUBSTRUCTURE ***.

          Item name is illegal. Occurs with user DMAP ALTERs only.

6104  ***  SYSTEM FATAL MESSAGE 6104, ATTEMPT TO CREATE DUPLICATE SUBSTRUCTURE
           NAME ***.

6105  ***  USER FATAL MESSAGE 6105, ATTEMPT TO RE-USE SUBSTRUCTURE *** IN A
           REDUCE OR COMBINE OPERATION. USE EQUIV SUBSTRUCTURE COMMAND.

          A single substructure may be reduced or combined more than once
          only after it is given a new name with the EQUIV substructure
          command.

6106  ***  SYSTEM FATAL MESSAGE 6106, UNEXPECTED END OF GROUP ENCOUNTERED WHILE
           READING ITEM *** SUBSTRUCTURE ***.

          Required data is missing or is of inconsistent length.

6107  ***  SYSTEM FATAL MESSAGE 6107, UNEXPECTED END OF ITEM ENCOUNTERED WHILE
           READING ITEM *** SUBSTRUCTURE ***.

          One or more of the required number of data groups is missing.

6108  ***  SYSTEM FATAL MESSAGE 6108, INSUFFICIENT SPACE ON SOF FOR ITEM ***,
           SUBSTRUCTURE ***.

6201  ***  SYSTEM INFORMATION MESSAGE 6201, *** FILES HAVE BEEN ALLOCATED TO
           THE SOF WHERE
           SIZE OF FILE 1   = *** BLOCKS
             :
             :
           SIZE OF FILE *** = ***  BLOCKS
           AND WHERE A BLOCK CONTAINS *** WORDS.

6202  ***  USER FATAL MESSAGE 6202, THE REQUESTED NUMBER OF FILES IS NON-
           POSITIVE.

          SOF file declaration is missing or illegal.

6204  ***  SYSTEM FATAL MESSAGE 6204, SUBROUTINE *** -. THE SUBROUTINE SOFOPN
           SHOULD BE CALLED PRIOR TO ANY OF THE SOF UTILITY SUBROUTINES.

6205  ***  USER FATAL MESSAGE 6205, SUBROUTINE *** - THE BUFFER SIZE HAS BEEN
           MODIFIED.

          The BUFFSIZE entry on the NASTRAN card input has been changed.

6206  ***  USER FATAL MESSAGE 6206, SUBROUTINE *** - WRONG PASSWORD ON SOF FILE
           ***.

6207  ***  USER FATAL MESSAGE 6207, SUBROUTINE *** - THE SOF FILE *** IS OUT OF
           SEQUENCE.

          The SOF file declarations are in the wrong order.

6208  ***  USER FATAL MESSAGE 6208, SUBROUTINE *** - THE SIZE OF THE SOF FILE
           *** HAS BEEN MODIFIED.

          Only the last SOF file may be increased. None may be decreased.

6209  ***  USER FATAL MESSAGE 6209, SUBROUTINE *** - THE NEW SIZE OF FILE *** IS
           TOO SMALL.

6211  ***  USER WARNING MESSAGE 6211, MODULE *** - ITEM *** OF SUBSTRUCTURE ***
           HAS ALREADY BEEN WRITTEN.

          Program will not write over existing data.

6212  ***  USER WARNING MESSAGE 6212, MODULE *** - THE SUBSTRUCTURE *** DOES NOT
           EXIST.

6213  ***  USER WARNING MESSAGE 6213, MODULE *** - *** IS AN ILLEGAL ITEM NAME.

6215  ***  USER WARNING MESSAGE 6215, MODULE *** - ITEM *** OF SUBSTRUCTURE ***
           PSEUDO-EXISTS ONLY.

6216  ***  USER WARNING MESSAGE 6216, MODULE *** - ITEM *** OF SUBSTRUCTURE ***
           DOES NOT EXIST.

6217  ***  USER WARNING MESSAGE 6217, MODULE *** - *** IS AN ILLEGAL PARAMETER
           NAME.

6218  ***  USER WARNING MESSAGE 6218, MODULE *** - THE SUBSTRUCTURE *** CANNOT
           BE DESTROYED BECAUSE IT IS AN IMAGE SUBSTRUCTURE.

6219  ***  USER WARNING MESSAGE 6219, MODULE *** RUN EQUALS DRY OR STEP, AND,
           SUBSTRUCTURE *** OR ONE OF THE NEW NAMES ALREADY EXISTS.

6220  ***  USER WARNING MESSAGE 6220, MODULE *** - RUN EQUALS GO, AND,
           SUBSTRUCTURE *** OR ONE OF THE NEW NAMES DOES NOT EXIST.

6222  ***  SYSTEM FATAL MESSAGE 6222 - ATTEMPT TO CALL SOFOPN MORE THAN ONCE
           WITHOUT CALLING SOFCLS.

6223  ***  USER FATAL MESSAGE 6223, SUBROUTINE *** - THERE ARE NO MORE FREE
           BLOCKS AVAILABLE ON THE SOF.

6224  ***  SYSTEM FATAL MESSAGE 6224, SOF UTILITY SUBROUTINE ***.

          Text follows the message to describe the error.

6225  ***  SYSTEM FATAL MESSAGE 6225, BLOCK NUMBER *** OUT OF RANGE OF SOF
           FILES.

          This means the SOF file does not contain all the data expected.
          Check previous jobs to verify where the intended SOF write
          operation may have failed, or determine if more information was
          expected.

6226  ***  SYSTEM WARNING MESSAGE 6226, SUBROUTINE SOFIO - HIBLK PARAMETER FOR
           SOFIO DID NOT CONFORM TO PHYSICAL FILE. PARAMETER VALUE HAS BEEN
           CHANGED FROM *** TO ***.

          This can be caused when the previous run using the SOF terminated
          abnormally. (CDC only.)

6227  ***  SYSTEM FATAL MESSAGE 6227, AN ATTEMPT HAS BEEN MADE TO OPERATE ON THE
           MATRIX ITEM *** OF SUBSTRUCTURE *** USING SFETCH.

6228  ***  USER INFORMATION MESSAGE 6228, SUBSTRUCTURE *** IS ALREADY EQUIVALENT
           TO SUBSTRUCTURE ***. ONLY ITEMS NOT PREVIOUSLY EXISTING FOR *** HAVE
           BEEN MADE EQUIVALENT.

6229  ***  USER INFORMATION MESSAGE 6229, SUBSTRUCTURE *** HAS BEEN RENAMED TO
           ***.

6230  ***  USER WARNING MESSAGE 6230, SUBSTRUCTURE *** HAS NOT BEEN RENAMED
           BECAUSE *** ALREADY EXISTS ON THE SOF.

6231  ***  USER WARNING MESSAGE 6231, INSUFFICIENT CORE AVAILABLE OR ILLEGAL
           ITEM FORMAT REQUIRES AN UNFORMATTED DUMP TO BE PERFORMED FOR ITEM ***
           OF SUBSTRUCTURE ***.

6232  ***  SYSTEM FATAL MESSAGE 6232, ERROR OCCURRED WHILE INITIALIZING SOF FILE
           ***.

          An error occurred while initializing an SOF file on the IBM
          360/370. The nature of the error follows the message.

6233  ***  USER WARNING MESSAGE 6233, THE ITEM STRUCTURE HAS BEEN CHANGED ON THE
           SOF. NEW CAPABILITIES USING THESE ITEMS MAY NOT BE USED WITH THIS
           SOF.

6234  ***  USER FATAL MESSAGE 6234, THE NASTRAN BUFFER SIZE IS TOO SMALL FOR THE
           SOF FILE. MINIMUM BUFFER SIZE IS ***.

6235  ***  USER WARNING MESSAGE 6235, THE OLD SOF CONTAINS NO ITEM STRUCTURE
           INFORMATION. THE LEVEL 16.0 ITEM STRUCTURE WILL BE USED.

6236  ***  USER WARNING MESSAGE 6236, DURING THE CREATION OF A NEW IMAGE
           SUBSTRUCTURE NAME, THE LAST CHARACTER OF SUBSTRUCTURE NAME *** WAS
           TRUNCATED TO MAKE ROOM FOR THE PREFIX.

6237  ***  SYSTEM WARNING MESSAGE 6237, THE SOFTOC ROUTINE CAN HANDLE ONLY ***
           ITEMS. ADDITIONAL ITEMS WILL NOT BE SHOWN.

6301  ***  SYSTEM FATAL MESSAGE 6301, DATA MISSING IN GO MODE FOR SUBSTRUCTURE
           ***, ITEM ***.

          You have deleted an item created in dry run mode or the item has
          been lost lost due to errors.

6302  ***  SYSTEM FATAL MESSAGE 6302, *** IS ILLEGAL MATRIX TYPE FOR MODULE
           COMB2.

6303  ***  SYSTEM FATAL MESSAGE 6303, HORG TRANSFORMATION MATRIX FOR
           SUBSTRUCTURE *** CANNOT BE FOUND ON SOF.

6304  ***  SYSTEM FATAL MESSAGE 6304, MODULE COMB2 INPUT MATRIX NUMBER *** FOR
           SUBSTRUCTURE *** HAS INCOMPATIBLE DIMENSIONS.

          Matrix dimensions conflict with those of its H or G transformation
          matrix.

6305  ***  SYSTEM WARNING MESSAGE 6305, RECORD NUMBER *** OF CASESS IS NOT A
           RECOVER RECORD. IT IS A *** RECORD.

          The step parameter for module RCOVR in incorrect. It should be the
          CASESS record number of a recover record.

6306  ***  USER WARNING MESSAGE 6306, ATTEMPT TO RECOVER DISPLACEMENTS FOR NON-
           EXISTENT SUBSTRUCTURE ***.

6307  ***  USER WARNING MESSAGE 6307, WHILE ATTEMPTING TO RECOVER DISPLACEMENTS
           FOR SUBSTRUCTURE ***, THE DISPLACEMENTS FOR SUBSTRUCTURE *** WERE
           FOUND TO EXIST IN DRY RUN FORM ONLY.

          Before you can recover displacements of any substructure, you must
          first perform an actual solution. See RUN substructure command.

6308  ***  USER WARNING MESSAGE 6308, NO SOLUTION AVAILABLE FROM WHICH
           DISPLACEMENTS FOR SUBSTRUCTURE *** CAN BE RECOVERED. HIGHEST LEVEL
           SUBSTRUCTURE FOUND WAS ***.

          Solve the highest level substructure found or combine it to an even
          higher level and solve.

6309  ***  SYSTEM FATAL MESSAGE 6309, INSUFFICIENT TIME REMAINING TO RECOVER
           DISPLACEMENTS OF SUBSTRUCTURE *** FROM THOSE OF SUBSTRUCTURE ***.
           (PROCESSING USER RECOVER REQUEST FOR SUBSTRUCTURE ***.)

6310  ***  SYSTEM WARNING MESSAGE 6310, INSUFFICIENT SPACE ON SOF TO RECOVER
           DISPLACEMENTS OF SUBSTRUCTURE *** FROM THOSE OF SUBSTRUCTURE ***
           WHILE PROCESSING USER RECOVER REQUEST FOR SUBSTRUCTURE ***.

          Use the SOF substructure command and increase the size of the SOF
          and/or add more SOF units. Alternatively, use EDIT to remove
          unwanted data.

6311  ***  SYSTEM WARNING MESSAGE 6311, SDCOMP DECOMPOSITION FAILED ON KOO
           MATRIX FOR SUBSTRUCTURE ***.

          The KOO matrix has been changed from the original REDUCE run. The
          local effects of non-boundary loads will be ignored.

6312  ***  USER INFORMATION MESSAGE 6312, LEVEL *** DISPLACEMENTS FOR
           SUBSTRUCTURE *** HAVE BEEN RECOVERED AND SAVED ON SOF.

6313  ***  SYSTEM WARNING MESSAGE 6313, INSUFFICIENT CORE FOR RCOVR MODULE
           WHILE TRYING TO PROCESS PRINTOUT DATA BLOCKS FOR SUBSTRUCTURE.

6314  ***  SYSTEM WARNING MESSAGE 6314, OUTPUT REQUEST CANNOT BE HONORED. RCOVR
           MODULE OUTPUT DATA BLOCK *** IS PURGED.

          An illegal type of output for the solution rigid format has been
          requested.

6315  ***  USER WARNING MESSAGE 6315, RCOVR MODULE IS UNABLE TO FIND
           SUBSTRUCTURE *** AMONG THOSE ON EQSS. LOAD SET *** FOR THAT
           SUBSTRUCTURE WILL BE IGNORED IN CREATING THE SOLN ITEM FOR FINAL
           SOLUTION STRUCTURE ***.

          Illegal name used in PRINT or SAVE request.

6316  ***  USER WARNING MESSAGE 6316, RCOVR MODULE IS UNABLE TO FIND LOAD SET
           *** FOR SUBSTRUCTURE *** AMONG THOSE ON LODS. IT WILL BE IGNORED IN
           CREATING THE SOLN ITEMS FOR FINAL SOLUTION STRUCTURE ***.

          Case Control data was probably changed between SOLVE and the first
          RECOVER steps. Message 6331 will define the error in SOLVE.

6317  ***  SYSTEM WARNING MESSAGE 6317, RECOVER OF DISPLACEMENTS FOR
           SUBSTRUCTURE *** ABORTED.

6318  ***  SYSTEM WARNING MESSAGE 6318, OUTPUT REQUEST FOR REACTION FORCES
           IGNORED.

6319  ***  SYSTEM WARNING MESSAGE 6319, DISPLACEMENT MATRIX FOR SUBSTRUCTURE ***
           MISSING. DISPLACEMENT OUTPUT REQUESTS CANNOT BE HONORED AND SPCFORCE
           OUTPUT REQUESTS CANNOT BE HONORED UNLESS THE REACTIONS HAVE BEEN
           PREVIOUSLY COMPUTED.

6320  ***  SYSTEM WARNING MESSAGE 6320, LOADC DATA MISSING FOR SUBSTRUCTURE ***,
           EXTERNAL STATIC LOAD SET ***.

          No LOADC bulk data cards can be found on GEOM4 or GEOM4 is purged.

6321  ***  USER INFORMATION MESSAGE 6321, SUBSTRUCTURE PHASE3 RECOVER FOR FINAL
           SOLUTION STRUCTURE *** AND BASIC SUBSTRUCTURE ***.

6322  ***  SYSTEM FATAL MESSAGE 6322, SOLN ITEM HAS INCORRECT RIGID FORMAT
           NUMBER. PHASE2 RIGID FORMAT WAS *** AND PHASE3 IS ***.

          The Rigid Format of Phase 3 must be the same as that used in Phase
          2 to obtain the solution.

6323  ***  USER WARNING MESSAGE 6323, NO EIGENVALUES FOR THIS SOLUTION.

6324  ***  USER FATAL MESSAGE 6324, PHASE3 RECOVER ATTEMPTED FOR NON-BASIC
           SUBSTRUCTURE ***.

          Substructure Phase 3 can be executed only for basic substructures
          or their equivalents.

6325  ***  USER WARNING MESSAGE 6325, SUBSTRUCTURE PHASE1, BASIC SUBSTRUCTURE
           *** ALREADY EXISTS ON SOF. ITEMS WHICH ALREADY EXIST WILL NOT BE
           REGENERATED.

          Use DESTROY or EDIT to remove items which are to be regenerated.

6326  ***  USER WARNING MESSAGE 6326, SUBSTRUCTURE ***, ITEM *** ALREADY EXISTS
           ON SOF.

          Follows message 6325, above.

6327  ***  USER INFORMATION MESSAGES 6327, SUBSTRUCTURE ***, SUBCASE *** IS
           IDENTIFIED BY *** SET *** IN LODS ITEM. REFER TO THIS NUMBER ON LOADC
           CARDS.

6328  ***  SYSTEM FATAL MESSAGE 6328, MORE THAN 100 SUBCASES DEFINED. SGEN
           PROGRAM LIMIT EXCEEDED.

          To increase this limit to more than 100 subcases, change the
          dimensions of local arrays LOAD, MPC, and SPC in subroutine SGEN
          and change the IF test which causes termination.

6329  ***  USER FATAL MESSAGE 6329, SUBSTRUCTURE ***, REFERENCES ON *** CARD, IS
           NOT A COMPONENT BASIC SUBSTRUCTURE OF SOLUTION STRUCTURE ***.

6330  ***  USER FATAL MESSAGE 6330, SOLUTION SUBSTRUCTURE *** -- *** AND CARDS
           CANNOT BE USED TOGETHER. USE EITHER ONE, BUT NOT BOTH.

6331  ***  USER FATAL MESSAGE 6331, SOLUTION SUBSTRUCTURE *** -- LOADC SET
           REFERENCES UNDEFINED LOAD SET *** OF BASIC SUBSTRUCTURE ***.

6332  ***  SYSTEM FATAL MESSAGE 6332, CANNOT FIND LOAD VECTOR NUMBER *** IN LOAD
           MATRIX OF *** COLUMNS BY *** ROWS FOR SOLUTION STRUCTURE ***.

          The wrong load matrix is being used.

6333  ***  USER FATAL MESSAGE 6333, *** IS AN INVALID FORMAT PARAMETER FOR
           MODULE EXIO.

          An illegal value was given in the SOFIN, SOFOUT, DUMP, or RESTORE
          command.

6334  ***  USER WARNING MESSAGE 6334, EXIO DEVICE PARAMETER SPECIFIES TAPE, BUT
           UNIT *** IS NOT A PHYSICAL TAPE.

6335  ***  USER WARNING MESSAGE 6335, *** IS AN INVALID DEVICE FOR MODULE EXIO.

6336  ***  USER INFORMATION MESSAGE 6336, EXIO FILE IDENTIFICATION. PASSWORD
           ***. DATE ***. TIME ** ** **.

          This message is caused when an I/O operation is requested. The date
          (in the form mm/dd/yy) and the time (in the form hh-mm-ss) indicate
          when the operation began.

6337  ***  USER INFORMATION MESSAGE 6337, *** BLOCKS (*** SUPERBLOCKS) OF THE
           SOF SUCCESSFULLY DUMPED TO EXTERNAL FILE ***.

6338  ***  USER WARNING MESSAGE 6338, *** IS AN INVALID MODE PARAMETER FOR
           MODULE EXIO.

6339  ***  USER WARNING MESSAGE 6339, *** IS AN INVALID FILE POSITIONING
           PARAMETER FOR MODULE EXIO.

6340  ***  USER WARNING MESSAGE 6340, SUBSTRUCTURE *** ITEM *** PSEUDO-EXISTS
           ONLY AND CANNOT BE COPIED OUT BY EXIO.

6341  ***  USER INFORMATION MESSAGE 6341, SUBSTRUCTURE *** ITEM *** SUCCESSFULLY
           COPIED FROM *** TO *** (***, ***).

          The message follows message 6336 to indicate the substructure item
          that was copied, the input file, and the output file. The
          information in parentheses is the date and time in the same form as
          described under message 6336.

6342  ***  USER WARNING MESSAGE 6342, SOF RESTORE OPERATION FAILED. THE RESIDENT
           SOF IS NOT EMPTY.

          Use the NEW option on the SOF substructure command to create a
          "new" SOF.

6343  ***  SYSTEM WARNING MESSAGE 6343, *** IS NOT AN EXTERNAL SOF FILE.

          Either (1) tape contained no data, (2) first record read was not an
          ID or header record, (3) tape was incorrectly positioned, or (4)
          GINO buffer size was changed.

6344  ***  USER INFORMATION MESSAGE 6344, SOF RESTORE OF *** BLOCKS SUCCESSFULLY
           COMPLETED.

6345  ***  USER WARNING MESSAGE 6345, SUBSTRUCTURE *** ITEM *** IS DUPLICATED ON
           EXTERNAL FILE ***. OLDER VERSION (***, ***) IS IGNORED.

6346  ***  USER WARNING MESSAGE 6346, SUBSTRUCTURE *** ITEM *** NOT COPIED. IT
           ALREADY EXISTS ON THE SOF.

6347  ***  USER INFORMATION MESSAGE 6347, SUBSTRUCTURE *** ADDED TO THE SOF.

           HIGHER LEVEL SUBSTRUCTURE ********

           COMBINED SUBSTRUCTURE     ********

           LOWER LEVEL SUBSTRUCTURE  ********

6348  ***  USER WARNING MESSAGE 6348, SUBSTRUCTURE *** ITEM *** NOT FOUND ON
           EXTERNAL FILE ***.

6349  ***  USER INFORMATION MESSAGE 6349, CONTENTS OF EXTERNAL SOF FILE ***
           FOLLOW.

6350  ***  USER WARNING MESSAGE 6350, SOF APPEND OF FILE *** FAILED. "text"

          The "text" explains why the append operation failed.

6351  ***  USER WARNING MESSAGE 6351, DUPLICATE SUBSTRUCTURE NAME *** FOUND
           DURING SOF APPEND OF FILE ***. THE SUBSTRUCTURE WITH THIS NAME ON THE
           FILE BEING APPENDED WILL BE PREFIXED WITH "Q".

6352  ***  USER INFORMATION MESSAGE 6352, EXTERNAL SOF FILE *** SUCCESSFULLY
           APPENDED TO THE RESIDENT SOF.

6353  ***  USER INFORMATION MESSAGE 6353, SUBSTRUCTURE *** ITEM *** HAS BEEN
           SUCCESSFULLY COMPRESSED.

6354  ***  USER INFORMATION MESSAGE 6354, THERE ARE *** FREE BLOCKS (*** WORDS)
           ON THE RESIDENT SOF.

6355  ***  SYSTEM INFORMATION MESSAGE 6355, EXIO TERMINATED WITH ERRORS. DRY RUN
           MODE ENTERED.

          The parameter DRY has been set to -2 to prevent matrix operations
          from occurring down stream in this run.

6356  ***  USER WARNING MESSAGE 6356, *** IS AN INVALID UNIT FOR MODULE EXIO,
           EXTERNAL FORMAT.

6357  ***  USER INFORMATION MESSAGE 6357, SUBSTRUCTURE *** ITEM *** SUCCESSFULLY
           COPIED FROM *** TO ***.

6358  ***  SYSTEM WARNING MESSAGE 6358, ILLEGAL RIGID FORMAT NUMBER *** IN SOLN
           ITEM FOR SUBSTRUCTURE ***. THE ITEM WILL NOT BE COPIED.

6359  ***  USER INFORMATION MESSAGE 6359, SUBSTRUCTURE *** WAS ORIGINALLY A
           SECONDARY SUBSTRUCTURE. ON THIS SOF, IT IS A PRIMARY SUBSTRUCTURE.

6360  ***  SYSTEM WARNING MESSAGE 6360, SOFOUT (EXTERNAL) ENCOUNTERED AN
           UNSUPPORTED TABLE ITEM ***. THE ITEM WILL NOT BE COPIED.

6361  ***  USER INFORMATION MESSAGE 6361, PHASE1 SUCCESSFULLY EXECUTED FOR
           SUBSTRUCTURE ***.

6362  ***  USER FATAL MESSAGE 6362, MPCS SET *** IS ILLEGAL. SUBSTRUCTURE ***
           GRID POINT *** COMPONENT *** SIGNIFIES A NON-UNIQUE DEPENDENT DEGREE
           OF FREEDOM.

6363  ***  USER WARNING MESSAGE 6363, INCOMPLETE DATA FOR SUBSTRUCTURE *** ITEM
           *** ON ***. THE ALL OUTPUT WILL BE PRODUCED.

6365  ***  USER WARNING MESSAGE 6365, REQUESTED OUTPUT SET ID *** IS NOT
           DECLARED IN CASE CONTROL, ALL OUTPUT WILL BE PRODUCED.

          Add "SET N = list" to the Case Control Deck.

6366  ***  USER WARNING MESSAGE 6366, THE RECOVER OUTPUT COMMAND SORT MUST
           APPEAR BEFORE THE FIRST BASIC SUBCOMMAND. ANY OTHER SORT COMMANDS ARE
           IGNORED.

6367  ***  USER WARNING MESSAGE 6367, ILLEGAL FORMAT ON THE RECOVER OUTPUT
           COMMAND ***, COMMAND IGNORED.

6368  ***  USER WARNING MESSAGE 6368, THE SUBSTRUCTURE *** APPEARING ON A BASIC
           COMMAND IS NOT A COMPONENT OF ***. ALL OUTPUT REQUESTS UNTIL THE NEXT
           BASIC, PRINT, OR SAVE ARE IGNORED.

6369  ***  USER FATAL MESSAGE 6369, SOLN ITEM HAS INCORRECT RIGID FORMAT NUMBER.
           SOLUTION RIGID FORMAT WAS *** AND CURRENT NASTRAN EXECUTION RIGID
           FORMAT IS ***.

6370  ***  USER FATAL MESSAGE 6370, A SOLUTION ON SUBSTRUCTURE *** WAS ATTEMPTED
           BUT PREVIOUS SOLUTION DATA EXISTED IN ITEM ***. THIS DATA MUST BE
           DELETED BEFORE A NEW SOLUTION CAN BE PERFORMED.

6371  ***  USER WARNING MESSAGE 6371, MODAL REDUCTION ENERGY CALCULATIONS FOR
           SUBSTRUCTURE *** ABORTED.

6501  ***  USER FATAL MESSAGE 6501, THE MANUAL COMBINE OPTION HAS BEEN
           SPECIFIED, BUT NO CONNECTION SET WAS GIVEN.

6505  ***  USER FATAL MESSAGE 6505, THE SYMMETRY OPTION *** CONTAINS AN INVALID
           SYMBOL.

          See the COMBINE substructure control description.

6506  ***  USER FATAL MESSAGE 6506, THE COMPONENT SUBSTRUCTURE *** IS NOT ONE OF
           THOSE ON THE COMBINE CARD.

6507  ***  USER FATAL MESSAGE 6507, THE SUBSTRUCTURE *** DOES NOT EXIST ON THE
           SOF.

6508  ***  USER FATAL MESSAGE 6508, THE NAME SPECIFIED FOR THE RESULTANT
           PSEUDOSTRUCTURE ALREADY EXISTS ON THE SOF.

6510  ***  USER FATAL MESSAGE 6510, THE REQUESTED COMBINE OPERATION REQUIRES
           SUBSTRUCTURE BULK DATA WHICH HAS NOT BEEN GIVEN.

          A CONNECT request requires CONCT, CONCT1, or RELES data.

6511  ***  USER FATAL MESSAGE 6511, THE REQUESTED TRANS SET ID *** HAS NOT BEEN
           DEFINED BY BULK DATA.

6512  ***  USER FATAL MESSAGE 6512, REDUNDANT CONNECTION SET ID-S HAVE BEEN
           SPECIFIED.

6513  ***  USER FATAL MESSAGE 6513, THE TRANS SET ID *** REQUESTED BY A GTRAN
           BULK DATA CARD HAS NOT BEEN DEFINED.

6514  ***  USER FATAL MESSAGE 6514, ERRORS HAVE BEEN FOUND IN THE MANUALLY
           SPECIFIED CONNECTION ENTRIES. SUMMARY FOLLOWS.

6515  ***  USER FATAL MESSAGE 6515, GRID POINT *** BASIC SUBSTRUCTURE *** DOES
           NOT EXIST.

6516  ***  USER INFORMATION MESSAGE 6516, ALL MANUAL CONNECTIONS SPECIFIED ARE
           ALLOWABLE WITH RESPECT TO TOLER.

6517  ***  USER FATAL MESSAGE 6517, THE BASIC SUBSTRUCTURE *** REFERRED TO BY A
           RELES BULK DATA CARD CANNOT BE FOUND IN THE PROBLEM TABLE OF
           CONTENTS.

6518  ***  USER FATAL MESSAGE 6518, ONE OF THE COMPONENT SUBSTRUCTURES HAS BEEN
           USED IN A PREVIOUS COMBINE OR REDUCE.

          Each substructure may be used in only one COMBINE or REDUCE. The
          previous COMBINE or REDUCE must be DESTROYed before it may be used
          again. An alternative is to EQUIV the substructure in question to a
          new substructure and then use the new substructure in the desired
          COMBINE operation. See message 6105.

6519  ***  USER FATAL MESSAGE 6519, REDUNDANT NAMES FOR RESULTANT
           PSEUDOSTRUCTURE HAVE BEEN SPECIFIED.

6520  ***  USER FATAL MESSAGE 6520, REDUNDANT VALUES FOR TOLER HAVE BEEN
           SPECIFIED.

6521  ***  USER INFORMATION MESSAGE 6521, MODULE COMB1 SUCCESSFULLY COMPLETED.

6522  ***  USER FATAL MESSAGE 6522, THE BASIC SUBSTRUCTURE *** REFERRED TO BY A
           CONCT1 BULK DATA CARD CANNOT BE FOUND IN THE PROBLEM TABLE OF
           CONTENTS.

6523  ***  USER FATAL MESSAGE 6523, THE BASIC SUBSTRUCTURE *** REFERRED TO BY A
           CONCT BULK DATA CARD CANNOT BE FOUND IN THE PROBLEM TABLE OF
           CONTENTS.

6524  ***  USER FATAL MESSAGE 6524, NO. OF COLUMNS OF MATRIX E IN MYP3 IS
           UNEQUAL TO NO. OF COLUMNS OF MATRIX B FOR A(T)B + E PROBLEM.

          This is a system error if you are not using DMAP.

6525  ***  USER INFORMATION MESSAGE 6525, TRIPLE MULTIPLY TIME ESTIMATE FOR MYP3
(1)        = ********** SECONDS.

6525  ***  USER INFORMATION MESSAGE 6525, TRIPLE MULTIPLY TIME ESTIMATE FOR
(2)        MYPAD - (AT * B)* A + E = ********** SECONDS.

6525  ***  USER INFORMATION MESSAGE 6525, TRIPLE MULTIPLY TIME ESTIMATE FOR
           MPYAD -  AT * (B*A) + E = ********** SECONDS.

6526  ***  USER INFORMATION MESSAGE 6526, THE CENTER MATRIX IS TOO LARGE FOR IN-
           CORE PROCESSING. OUT-OF-CORE PROCESSING WILL BE PERFORMED.

          Issued by the MPYS module.

6528  ***  USER FATAL MESSAGE 6528, INCOMPATIBLE LOCAL COORDINATE SYSTEMS HAVE
           BEEN FOUND. CONNECTION OF POINTS IS IMPOSSIBLE, SUMMARY FOLLOWS.

6530  ***  USER FATAL MESSAGE 6530, THE BASIC SUBSTRUCTURE *** REFERRED TO BY A
           GTRAN CARD CANNOT BE FOUND IN THE PROBLEM TABLE OF CONTENTS.

6531  ***  USER FATAL MESSAGE 6531, NO CONNECTIONS HAVE BEEN FOUND DURING THE
           AUTOMATIC CONNECTION PROCEDURE.

6533  ***  USER FATAL MESSAGE 6533, OPTIONS PA HAS BEEN SPECIFIED BUT THE LOAP
           ITEM ALREADY EXISTS FOR SUBSTRUCTURE ***.

          You must delete old appended loads before running with new appended
          loads.

6534  ***  USER FATAL MESSAGE 6534, OPTIONS PA HAS BEEN SPECIFIED BUT THE
           STRUCTURE *** DOES NOT EXIST. YOU CANNOT APPEND SOMETHING TO NOTHING.

6535  ***  USER FATAL MESSAGE 6535, MODULE COMB1 TERMINATING DUE TO ABOVE
           SUBSTRUCTURE CONTROL ERRORS.

6536  ***  USER FATAL MESSAGE 6536, MODULE COMB1 TERMINATING DUE TO ABOVE
           ERRORS IN BULK DATA.

6537  ***  USER FATAL MESSAGE 6537, MODULE COMB1 TERMINATING DUE TO ABOVE
           ERRORS.

6551  ***  USER FATAL MESSAGE 6551, MATRIX B IN MPY3 IS NOT SQUARE FOR A(T)BA +
           E PROBLEM.

6552  ***  USER FATAL MESSAGE 6552, NO. OF ROWS OF MATRIX A IN MPY3 IS UNEQUAL
           TO NO. OF ROWS OF MATRIX B FOR A(T)B + E PROBLEM.

6553  ***  USER FATAL MESSAGE 6553, NO. OF ROWS OF MATRIX A IN MPY3 IS UNEQUAL
           TO NO. OF COLUMNS OF MATRIX B FOR A(T)BA + E PROBLEM.

6554  ***  USER FATAL MESSAGE 6554, NO. COLUMNS OF MATRIX E IN MPY3 IS UNEQUAL
           TO NO. OF COLUMNS OF MATRIX A FOR A(T)BA + E PROBLEM.

6555  ***  USER FATAL MESSAGE 6555, MATRIX E IN MPY3 IS NOT SQUARE FOR A(T)BA +
           E PROBLEM.

6556  ***  USER FATAL MESSAGE 6556, NO. OF ROWS OF MATRIX E IN MPY3 IS UNEQUAL
           TO NO. OF ROWS OF MATRIX B FOR BA + E PROBLEM.

6557  ***  USER FATAL MESSAGE 6557, UNEXPECTED NULL COLUMN OF A(T) ENCOUNTERED.

          Issued by MPY3 module.

6558  ***  USER FATAL MESSAGE 6558, INSUFFICIENT TIME REMAINING FOR MPY3
           EXECUTION.

6559  ***  USER FATAL MESSAGE 6559, NO. OF ROWS OF MATRIX E IN MPY3 IS UNEQUAL
           TO NO. OF COLUMNS OF MATRIX A FOR A(T)B + E PROBLEM.

6601  ***  USER FATAL MESSAGE 6601, REQUEST TO REDUCE PSEUDOSTRUCTURE ***
           INVALID. DOES NOT EXIST ON THE SOF.

6602  ***  USER FATAL MESSAGE 6602, THE NAME *** CANNOT BE USED FOR THE REDUCED
           PSEUDOSTRUCTURE. IT ALREADY EXISTS ON THE SOF.

6603  ***  USER FATAL MESSAGE 6603, A BOUNDARY SET MUST BE SPECIFIED FOR A
           REDUCE OPERATION.

6604  ***  USER WARNING MESSAGE 6604, A BOUNDARY SET HAS BEEN SPECIFIED FOR ***,
           BUT IT IS NOT A COMPONENT OF THE PSEUDOSTRUCTURE BEING REDUCED. THE
           BOUNDARY SET WILL BE IGNORED.

6605  ***  USER WARNING MESSAGE 6605, A BOUNDARY SET HAS BEEN SPECIFIED FOR ***
           BUT IT IS NOT A PHASE1 BASIC SUBSTRUCTURE. THE BOUNDARY SET WILL BE
           IGNORED.

6606  ***  USER FATAL MESSAGE 6606, BOUNDARY SET *** SPECIFIED IN CASE CONTROL
           HAS HOT BEEN DEFINED BY BULK DATA.

          No BDYC bulk data has been entered.

6607  ***  USER FATAL MESSAGE 6607, NO BDYS OR BDYS1 BULK DATA HAS BEEN INPUT TO
           DEFINE BOUNDARY SET ***.

6608  ***  USER FATAL MESSAGE 6608, THE REQUEST FOR BOUNDARY SET ***,
           SUBSTRUCTURE *** WAS NOT DEFINED.

6609  ***  USER INFORMATION MESSAGE 6609, NO BOUNDARY SET HAS BEEN SPECIFIED FOR
           COMPONENT OF PSEUDOSTRUCTURE ***. ALL DEGREES OF FREEDOM WILL BE
           REDUCED.

6610  ***  USER WARNING MESSAGE 6610, DEGREES OF FREEDOM AT GRID POINT ***
           COMPONENT SUBSTRUCTURE *** INCLUDED IN A BOUNDARY SET DO NOT EXIST.
           REQUEST WILL BE IGNORED.

6611  ***  USER FATAL MESSAGE 6611, GRID POINT *** SPECIFIED IN BOUNDARY SET ***
           FOR SUBSTRUCTURE *** DOES NOT EXIST.

6612  ***  USER FATAL MESSAGE 6612, THE REDUCE OPERATION REQUIRES SUBSTRUCTURE
           BULK DATA WHICH HAS NOT BEEN GIVEN.

6613  ***  USER FATAL MESSAGE 6613, FOR RUN=GO, THE REDUCED SUBSTRUCTURE ***
           MUST ALREADY EXIST.

6614  ***  USER FATAL MESSAGE 6614, ILLEGAL OR NON-EXISTENT STRUCTURE NAME USED
           ABOVE.

6615  ***  USER FATAL MESSAGE 6615, ILLEGAL BOUNDARY SET IDENTIFICATION NUMBER.

6616  ***  USER INFORMATION MESSAGE 6616, MODULE REDUCE SUCCESSFULLY COMPLETED.

6617  ***  USER FATAL MESSAGE 6617, OLDMODES SET AND REQUESTED SOF ITEM DOES NOT
           EXIST. ITEM ***, SUBSTRUCTURE ***.

6618  ***  USER FATAL MESSAGE 6618, OLDMODES NOT SET AND REQUESTED SOF ITEM MUST
           BE DELETED. ITEM ***, SUBSTRUCTURE ***.

6619  ***  USER FATAL MESSAGE 6619, OLDBOUND SET AND REQUESTED SOF ITEM DOES NOT
           EXIST. ITEM ***, SUBSTRUCTURE ***.

6620  ***  USER FATAL MESSAGE 6620, OLDBOUND NOT SET AND REQUESTED SOF ITEM
           MUST BE DELETED, ITEM ***, SUBSTRUCTURE ***.

6621  ***  USER FATAL MESSAGE 6621, FIXED SET *** SPECIFIED IN CASE CONTROL HAS
           NOT BEEN DEFINED BY BULK DATA.

6622  ***  USER WARNING MESSAGE 6622, A FIXED SET HAS BEEN SPECIFIED FOR ***,
           BUT IT IS NOT A COMPONENT OF THE PSEUDOSTRUClURE BEING PROCESSED. THE
           FIXED SET WILL BE IGNORED.

6623  ***  USER FATAL MESSAGE 6623, SUBSTRUCTURE *** HAS DUPLICATE NAMES IN BDYC
           DATA SET ***.

6624  ***  USER FATAL MESSAGE 6624, GRID POINT *** SPECIFIED IN FIXED SET ***
           FOR SUBSTRUCTURE *** DOES NOT EXIST.

6625  ***  USER WARNING MESSAGE 6625, DEGREES OF FREEDOM AT GRID POINT ***
           COMPONENT SUBSTRUCTURE *** INCLUDED IN A FIXED SET DO NOT EXIST.
           REQUEST WILL BE IGNORED.

6626  ***  USER FATAL MESSAGE 6626, NO BDYS OR BDYS1 BULK DATA HAS BEEN INPUT TO
           DEFINE FIXED SET ***.

6627  ***  USER FATAL MESSAGE 6627, NO EIG* DATA CARDS SPECIFIED FOR SET ID ***,
           SUBSTRUCTURE ***.

6628  ***  USER FATAL MESSAGE 6628, NO EIGC OR EIGR DATA CARDS SPECIFIED FOR SET
           ID ***, SUBSTRUCTURE ***.

6629  ***  USER FATAL MESSAGE 6629, NO EIGC DATA CARD SPECIFIED WITH EIGP DATA
           CARD SET ID ***, SUBSTRUCTURE ***.

6630  ***  USER INFORMATION MESSAGE 6630, FOR DRY OPTION IN MODAL REDUCE, INPUT
           DATA WILL BE CHECKED BUT NO SOF TABLE ITEMS WILL BE CREATED.

6631  ***  USER POTENTIALLY FATAL MESSAGE 6631, IN COMPLEX MODAL REDUCE, ONLY
           ONE H TRANSFORMATION MATRIX IS PRESENT ON SOF FOR NONSYMMETRIC
           REDUCTION.

6632  ***  USER FATAL MESSAGE 6632, MODULE ***, NASTRAN MATRIX FILE FOR I/O OF
           SOF ITEM ***, SUBSTRUCTURE ***, IS PURGED.

6633  ***  USER FATAL MESSAGE 6633, FOR SUBSTRUCTURE *** TOTAL NUMBER OF MODAL
           COORDINATES (***) IS LARGER THAN THE NUMBER OF INTERIOR DOF (***).

6634  ***  USER FATAL MESSAGE 6634, IN MODULE MREDUCE WITH USER MODE=2, THE
           CONSTRAINT FORCES MATRIX IS INCOMPATIBLE WITH THE NUMBER OF MODES
           (***).

6635  ***  USER WARNING MESSAGE 6635, CDCOMP DECOMPOSITION FAILED ON KII MATRIX
           FOR SUBSTRUCTURE ***.

6636  ***  USER INFORMATION MESSAGE 6636, NMAX AND RANGE SUBCOMMANDS ARE IGNORED
           UNDER USERMODE = TYPE 2.

6637  ***  USER FATAL MESSAGE 6637, OLDBOUND HAS BEEN SPECIFIED BUT THE BOUNDARY
           POINTS FOR SUBSTRUCTURE *** HAVE BEEN CHANGED.

          The boundary set data for the current problem is different from the
          boundary set data which created the UPRT SOF item for this
          substructure.

6638  ***  USER FATAL MESSAGE 6638, IN MODULE MREDUCE WITH USER MODE=2, THE
           CONSTRAINT FORCES MATRIX (QSM) CANNOT BE PURGED.

6900  ***  USER INFORMATION MESSAGE 6900, LOADS HAVE BEEN SUCCESSFULLY APPENDED
           FOR SUBSTRUCTURE ***.

6901  ***  USER INFORMATION MESSAGE 6901, ADDITIONAL LOADS HAVE BEEN
           SUCCESSFULLY MERGED FOR SUBSTRUCTURE ***.

6951  ***  USER FATAL MESSAGE 6951, INSUFFICIENT CORE TO LOAD TABLES. IN MODULE
           LODAPP, CORE = ***.

          The total number of load sets times two must fit in core.

6952  ***  USER FATAL MESSAGE 6952, REQUESTED SUBSTRUCTURE *** DOES NOT EXIST.

6953  ***  SYSTEM FATAL MESSAGE 6953, A WRONG COMBINATION OF LOAD VECTORS EXISTS
           FOR SUBSTRUCTURE ***.

          All load set IDs must be unique for each basic substructure.

6954  ***  SYSTEM FATAL MESSAGE 6954, THE **** ITEM EXISTS BUT HAS NO ASSOCIATED
           PVEC ITEM FOR SUBSTRUCTURE ********.

          A load set table exists, but the load vectors have been removed.

6956  ***  USER FATAL MESSAGE 6956, INSUFFICIENT TIME REMAINING FOR MODULE
           LODAPP, TIME LEFT = ********.

=PAGE=
6.9  FUNCTIONAL MODULE MESSAGES (7001 THROUGH 8000)

7019  ***  USER INFORMATION MESSAGE 7019, MODULE DSCHK IS EXITING FOR REASON ***
           ON ITERATION NUMBER ****** / PARAMETER VALUES ARE AS FOLLOWS DONE =
           **********, SHIFT = **********, DSEPSI = **********.

          See Sections 2.4.3 and 2.16.3 in Volume II for a discussion of DISP
          Rigid Format 4 and DISP Rigid Format 16 output features.

8000  ***  USER INFORMATION MESSAGE 8000, MODULE FLBMG TERMINATED DUE TO ABOVE
           ERRORS.

=PAGE=
6.10  FUNCTIONAL MODULE MESSAGES (8001 THROUGH 9000)

8001  ***  USER FATAL MESSAGE 8001, THERE MUST BE A FLUID/STRUCTURE BOUNDARY IN
           HYDROELASTIC ANALYSIS.

8002  ***  USER FATAL MESSAGE 8002, ELEMENT ID ******** ON A CFLSTR CARD DOES
           NOT REFERENCE A VALID 2D STRUCTURAL ELEMENT.

8003  ***  USER FATAL MESSAGE 8003, ELEMENT ID ******** ON A CFLSTR CARD DOES
           NOT REFERENCE A VALID FLUID ELEMENT.

8004  ***  USER FATAL MESSAGE 8004, ELEMENT ID ******** ON A CFFREE CARD DOES
           NOT REFERENCE A VALID FLUID ELEMENT.

8005  ***  USER FATAL MESSAGE 8005, BAD GEOMETRY DEFINED FOR STRUCTURAL ELEMENT
           ********.

8006  ***  USER FATAL MESSAGE 8006, BAD GEOMETRY DEFINED FOR FACE ******** OF
           FLUID ELEMENT ********.

8007  ***  USER FATAL MESSAGE 8007, NO FACE ON FLUID ELEMENT ******** IS WITHIN
           30 DEGREES OF STRUCTURAL ELEMENT ********.

8008  ***  USER FATAL MESSAGE 8008, THE DISTANCE BETWEEN FLUID ELEMENT ********
           AND STRUCTURAL ELEMENT ******** IS GREATER THAN THE ALLOWED
           TOLERANCE.

8009  ***  USER FATAL MESSAGE 8009, FACE ******** SPECIFIED FOR FLUID ELEMENT
           ******** IS AN ILLEGAL VALUE.

8010  ***  SYSTEM FATAL MESSAGE 8010, LOGIC ERROR IN SUBROUTINE FLBEMA - CODE
           ***.

8011  ***  USER WARNING MESSAGE 8011, INSUFFICIENT CORE TO HOLD CONTENTS OF
           EQEXIN DATA BLOCK. HYDROELASTIC USET PRINTOUT TERMINATED.

8012  ***  USER FATAL MESSAGE 8012, FLUID ELEMENT ******** ON A CFFREE CARD
           REFERENCES UNDEFINED GRAVITY ID ********.

8013  ***  USER FATAL MESSAGE 8013, FLUID ELEMENT ******** ON A CFLSTR CARD
           REFERENCES UNDEFINED GRAVITY ID ********.

8014  ***  USER WARNING MESSAGE 8014, FlUID ELEMENT ******** AND STRUCTURE
           ELEMENT ******** ARE DISJOINT. CHECK CFLSTR CARDS.

8015  ***  USER WARNING MESSAGE 8015, THE PURELY INCOMPRESSIBLE METHOD IS
           AVAILABLE ONLY WITH THE DIRECT FORMULATION.